Delhi Jal Board - Delhi

35024494 electrification of water and sewer store ee ( m ) 41 under jangpura constituency ( ac 41 electrification of water and sewer store ee ( m ) 41 under jangpura constituency ( ac 41 ) . , electrification of following water and sewer stores under ee ( m ) 41 under jangpura constituency ( ac 41 ) : 1. nizamuddin sewer store 2. sarai kale khan sewer store 3. nehru nagar sewer store 4. sunlight colony sewer store 5. siddhartha extension water store 6. k block, lajpat nagar sewer store s / o 20w led batten light. make: bajaj / havells / crompton , s / o 70 / 72 w led street light. make: bajaj / havells / crompton , s / o 300 mm size exhaust fan.make:havells / orient / crompton , s / o 1200 mm size ceiling fan.make:havells / orient / crompton , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100 volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 10 sq.mm x 2 core armored cable. make: havells / polycab / any djb approved make. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , supplying and fixing following modular type switch / socket on the existing switch box / cover including connections etc. as required.5 / 6 a switch. , supplying and fixing following modular type switch / socket on the existing switch box / cover including connections etc. as required.6 pin 15 / 16 a socket outlet. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( up to 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. dsr7.7.1 , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way, double door. , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole. , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. double pole. , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. , earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Delhi Jal Board - Delhi

34395071 improvement of lighting system at je water store and newly constructed bps rooms in kalkaji constituency ( ac 51 ) . , the following works is to be carried out at shriniwaspuri water store, amritpuri garhi bps, sarai julena bps, c block ( old & new ) east of kailash bpss. s / o 20w led batten light. , s / o 70w led street light. , s / o 450 mm size exhaust fan. , s / o 1200 mm size ceiling fan. , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 10 sq.mm 2 core armored cable. make: any djb approved make , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , wiring for light / power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit along with 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.5 / 6 a switch. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.3 pin 5 / 6 a socket outlet. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.15 / 16 a switch. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.6 pin 15 / 16 a socket outlet. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way, double door. , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole. , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. double pole. , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. , earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Municipal Corporation - Delhi

34219237 repair and procurement of electrical items for day to day electrical maintenance in various mpl buildings ward 32s sagarpur east under najafgarh zone. supply of 1.5 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 2 supply of 2.5 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 3 supply of 4.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 4 supply of s.p. 5 / 6 amps, one way modular switch, isi marked 5 supply of3 pin 5 / 6 amps modular socket outlet, isi marked 6 supply of s.p. 15 / 16 amps, one way modular switch, isi marked 7 supply of 6 pin 15 / 16 amps modular socket outlet, isi marked 8 supply of modular base & cover plate for 3 module 9 supply of modular base & cover plate for 6 module 10 supply of modular base & cover plate for 12 module 11 supply of s.p. 15 / 16 amps, one way switch, piano type isi marked 12 supply of 6 pin 15 / 16 & 5 / 6 amps socket outlet, piano type isi marked 13 supply of 25 amps. ratings , sp mcb, “c” curve, 10 ka breaking capacity 14 supply of 32 amps. ratings , dp mcb, “c” curve, 10 ka breaking capacity 15 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required.group a 16 supply of 63 amps., 2 pole isolator 17 supply of 63 amps., 4 pole isolator 18 supply of 12 way, spn, double door, mcb db 19 supply of 14 way, spn, double door, mcb db 20 supply of 1200 mm sweep 50 watt, energy saver isi marked bee 5 star rating ac ceiling fan suitable for 230 v, 50 hertz ac supply without regulator with blades, downrod etc. complete as required. 21 supply, installation, testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240 / 415 volts, 50 hz ac supply. ( a ) 1 hp ( 0.75 kw ) single phase pump set, head from 12 30 mtrmtr, suction and delivery 25x25 mm...

Municipal Corporation - Delhi

34219170 supply of material for day to day maintenance and repair of electric installations in various mpl building in ward no. 39 s chhawla under najafgarh zone. supply of 1.5 sq. mm isi marked, fr pvc insulated, single core copper conductor cable 2 supply of 2.5 sq. mm isi marked, fr pvc insulated, single core copper conductor cable 3 supply of 4.0 sq. mm isi marked, fr pvc insulated, single core copper conductor cable 4 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required.group c 5 supply of 10 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 6 supply of s.p. 15 / 16 amps, one way switch, piano type isi marked 7 supply of 3 pin 5 / 6 amps socket outlet, piano type isi marked 8 supply of 6 pin 15 / 16 & 5 / 6 amps socket outlet, piano type isi marked 9 supply of 6 amps. to 32 amps. ratings , sp mcb, “c” curve, 10 ka breaking capacity 10 supply of 40 amps., 2 pole isolator 11 supply of 3 mm thick phenolic laminated sheet 12 supply of xlpe insulated and pvc sheathed al conductor un armoured cable confirming to is: 7098 of following size. 2x6 sqmm 13 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 14 supply of led tube type luminaire 20 watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient leds with the following ( a ) total system wattage 20 watt + / 5% ( b ) luminous efficacy lumens / watt>=95 ( c ) power factor >=0.95 15 supply of 1200mm sweep 50 watt, energy saver isi marked bee 5 star ratingac ceiling fan suitabble for 230 v, 50 hz ac supply without regulator with blades, downroad etc complete as required. 16 supply of 12 ( 300mm ) sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd...

Delhi Jal Board - Delhi

34094710 electrification of je store parwana road jagatpuri in ac 59 1 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required.1.3.3 / dsr 2022 2 wiring for circuit / sub main wiring along with earth wire with the following. sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire.1.14.2 3 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required.1.12 4 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 1.32 / dsr 2022 5 supplying and fixing following way, horizontal type three pole and neutral, sheet steel mcb distribution board, 415 v, on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) . 4 way ( 4 + 12 ) doule door.2.4.1 6 supplying & fixing 5 amp. to 32 amp. rating 240 / 415 v, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existingmcb db complete with connections, testing and commissioning etc. as required, single pole. 2.10.1 7 supplying & fixing 5 amp. to 32 amp. rating 240 / 415 v, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existingmcb db complete with connections, testing and commissioning etc. as required, single pole & neutral. 2.10.2 8 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required1.33 9 supply of powder coated regal batten type luminaries with led type of capacity 22 w, 1×22 w ftl hf type. make havells / crompton / polycab 10 supply of 1200 mm. sweep ceiling fans. make : ( orient / havells / crompton ) . 11 supply of225 mm. exhaustfans . make : ( orient / havells / crompton ) . 12 supply of 400 mm swing wall fan. make : ( bajaj / havells / crompton / orient ) . 13 supply of 2 x 10 sq. mm. aluminium conductor power armoured cable. polycab / grandlay / national. 14 supply and fixing of 1250 va ( 12v ) ups inverter with et2460 150 ah tall tubular battery with troellymake: microtech 15 supply of desert cooler of plastic body with 60 ltr capacity. make: symphony / bajaj / orient / havells 16 supply of 1 hp monoblock pump. make: crompton / djb approved make 17 supply of 70wled flood light ( polycab, crompton, havells ) 18 installation, testing and commissioning of pre wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required.1.41 19 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. also for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.1.50.1 & 1.51...

Delhi University - Delhi

34069727 electrical repairing work to be carried out in central science library, university of delhi . supplying and fixing suitable size g.i. box with modular plate and cover in front or in recess including providng and fixing 25a modular socket outlet and 25a modular sp mcb c curve including connectios, painting etc. as required. 2 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 3 1 x 1.5 sqmm 4 2 x 6 sq.mm 5 supplying and fixing of following sizes of heavy dutypvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 6 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required 4 x 16 sq. mm + 2 x 16 sq. mm earth wire 7 supplying and fixing of following ways surface / recess mounting, vertical type, 415 volts, tpn mcb distribution board of sheetsteel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcb’s ( but without mcb’s and incomer ) as required. ( note : vertical type mcb tpdb is normally used where 3 phase outlets are required. ) 8 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 9 supplying and fixing following rating four pole 415v isolaror in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 amps 10 s / f of double box type fittign complete with all accessories i / c making connection etc. as required tmc 501 2xt led 22w p 3242 i / c having 2 nos. of stellar 20 watts led tubelight in the existing fitting as required. 11 s / f of 20 watts stellar bright led tubelight having 2100k lumens in the existing fitting i / c making connection etc. as required 12 supplying / installation / testing and commissioning of 200 watts flood light led fitting having suitable angle frame, complete with all accessories i / c having pressure die cast aluminium housing with high power led as lighting source and lens embedded pc cover having top opening seperate driver compartment with ip66 protection and impact resistance of ik07 with kv build in spd i / c making connection as required. ( philips make cat ) 13 supplying and fixing of following accessories in the existing street light / flood light fitting i / c makingconnection etc. as required. 14 driver suiable for 70 watts fittings 15 surge protector 16 supplying / installation / testing and commissioning of 70 watts led street light fitting complete with all accessories i / c having pressure die cast aluminium housing with high power led as lighting source and lens embedded pc cover having top opening separate driver compartment with ip66 protection and impact resistance of ik07 with kv build in spd i / c making connection as required. ( philips make ) 17 s / f of snap on dlp trunking of 80mmx 50 mm with suitable on the existing wall / surface i / c having all the accessories such as flat angle, end caps, internal / external angle etc. as required at site. 18 supplying / laying of one number pvc insulated and pvc sheathed / xlpe aluminium cond. power cable of 1.1 kv grade of following size direct in ground i / c excavation, sand cushioning, protective covering and refilling the trench etc. as required at site. 4 x 16 sq.mm 19 dismantling the existing accessories and depositing the same at engineering store....

Municipal Corporation - Delhi

34063977 improvement of electrical installation and other allied works in various mpl buildings in ward no.4 holambi khurd under narela zone rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel conduit including dismantling as required. group c 2 s / d following size of frls pvc insulated copper conductor 1 core cable in existing surface / recessed / pvc / steel conduitas reqd. ( a ) 3x2.5 sq mm 3 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.upto 35 sq. mm 4 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm ( clamped with 1mm thick saddle ) 5 supply of xlpe insulated pvc sheathed al. cond. un armoured cable of 1.1kv grade conforming to is 7098 part i of following sizea ) 2 x 10 sqmm 6 supply and fixing 3mm thick phenolic laminated sheet i / c cutting of sheet, bolt and washer etc as required. 7 replacement of fan condenser 2.5 mfd as reqd. 8 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 9 supply of 1200mm sweep 50 watt , energy saverisi marked bee 5 star rating ac ceiling fan suitable for 230 v, 50 hertz ac supply wihout regulator withblades, down rod etc complete as required. 10 providing and fixing following rating and breaking capacity and pole mccb with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. ( a ) 100amp, 16ka, tpmccb 11 ( b ) 200amp, 16ka, tpmccb 12 sitc of 60 watt led street light luminaire fitted with lens made of pressure die casting aluminium housing & toughened glass cover with following specificationas reqd ( a ) total system wattage =60 watt+ 5 % ( b ) luminous efficacy > =100 lumens / watt ( d ) power factor = > 0.95 ( e ) protection level ip 66 13 supply and fixing of 32mm dia g.i.pipe ( medium class ) 1mt.long bracket i / c wiring with 2.5 sq.mm copper conductor wire as reqd. 14 supplying and fixing of following sizes of medium class pvcconduit along with accessories in surface / recess includingcutting the wall and making good the same in case of recessedconduit as required.a. 25 mm 15 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 5 / 6 amp switch 16 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 3 pin 5 / 6 amp socket outlet 17 supplying and fixing pvc batten / angle holder including connection etc. as required. 18 supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole 19 supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.a. 40 amps 20 supplying of 9 / 10 watt led lamp suitable for b22 holder. 21 supply, installation , testing & commissioning of led tube type fixture 20watt rating complete with extruded aluminium batten prewired with hogh efficient leds.with the following ( a ) total system wattage 20 watt + / 5 % ( b ) luminous efficacy >= 95 lm / watt ( c ) power factor >= 0.95 with connections etc. complete as reqd. 22 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) ( a ) 6 way, double door...

Municipal Corporation - Delhi

34063961 improvement of electrical installations and other allied works in homoeopathic dispensary alipur in ward no.3 under narela zone 1 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel conduit including dismantling as required. group c 2 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 5 / 6 amp switch 3 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 3 pin 5 / 6 amp socket outlet 4 supply and fixing 3mm thick phenolic laminated sheet i / c cutting of sheet, bolt and washer etc as required. 5 supplying and fixing of following sizes of steel conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. ( b ) 25 mm 6 s / d following size of frls pvc insulated copper conductor 1 core cable in existing surface / recessed / pvc / steel conduitas reqd. ( a ) 3x2.5 sq mm 7 ( c ) 3x4sq mm 8 ( d ) 3x 6 sq mm 9 supplying and fixing metal box of 180mmx100mmx60mm deep ( normal size ) of surface or in recess with suitable size phenolic laminated sheet cover in the front i / c providing and fixing 6pin, 5 / 6 amps and 15 / 16amps socket outlet and 15 / 16amps piano type switch connection painting etc as required. 10 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) ( a ) 6 way, double door 11 supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole 12 supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. ( b ) 63 amps 13 supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required. 14 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 15 supply of 1200mm sweep 50 watt , energy saverisi marked bee 5 star rating ac ceiling fan suitable for 230 v, 50 hertz ac supply wihout regulator withblades, down rod etc complete as required. 16 supply, installation , testing & commissioning of led tube type luminaire 20watt rating complete with extruded aluminium batten prewired with high efficient led with the foolowing: ( a ) total system wattage20 watt + / 5% ( b ) luminous efficacy lumens / watt>=95 ( c ) power factor > =0.95...

Municipal Corporation - Delhi

34063897 improvement of electrical installation and other allied works in various mpl buildings in ward no.31 pooth khurd under narela zone rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel conduit including dismantling as required. group c 2 s / d following size of frls pvc insulated copper conductor 1 core cable in existing surface / recessed / pvc / steel conduitas reqd. ( a ) 3x2.5 sq mm 3 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.upto 35 sq. mm 4 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm ( clamped with 1mm thick saddle ) 5 supply of xlpe insulated pvc sheathed al. cond. un armoured cable of 1.1kv grade conforming to is 7098 part i of following sizea ) 2 x 10 sqmm 6 replacement of fan condenser 2.5 mfd as reqd. 7 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 8 supply of 1200mm sweep 50 watt , energy saverisi marked bee 5 star rating ac ceiling fan suitable for 230 v, 50 hertz ac supply wihout regulator withblades, down rod etc complete as required. 9 providing and fixing following rating and breaking capacity and pole mccb with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. ( a ) 100amp, 16ka, tpmccb 10 ( b ) 200amp, 16ka, tpmccb 11 sitc of 60 watt led street light luminaire fitted with lens made of pressure die casting aluminium housing & toughened glass cover with following specificationas reqd ( a ) total system wattage =60 watt+ 5 % ( b ) luminous efficacy > =100 lumens / watt ( d ) power factor = > 0.95 ( e ) protection level ip 66 12 supply and fixing of 32mm dia g.i.pipe ( medium class ) 1mt.long bracket i / c wiring with 2.5 sq.mm copper conductor wire as reqd. 13 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 5 / 6 amp switch 14 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 3 pin 5 / 6 amp socket outlet 15 supplying and fixing pvc batten / angle holder including connection etc. as required. 16 supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole 17 supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. a. 40 amps 18 supplying of 9 / 10 watt led lamp suitable for b22 holder. 19 supply, installation , testing & commissioning of led tube type fixture 20watt rating complete with extruded aluminium batten prewired with hogh efficient leds.with the following ( a ) total system wattage 20 watt + / 5 % ( b ) luminous efficacy >= 95 lm / watt ( c ) power factor >= 0.95 with connections etc. complete as reqd. 20 s / i / t / c of 1.0 h.p. single phase mono self priming pumping set having speed 1500 rpm suitable for a head of 18 to 45 mtr. discharge 2800 to 880 lmp amd suction / delivery 25x25 mm suitable to work 180 to 230 volt, a.c. supply including testing commissioning etc as reqd....

Delhi Jal Board - Delhi

33862677 renovation of electrical wiring, lighting and other electrical equipments at idgah bps. wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq. mm. frls pvc insulated copper conductor single core cable etc. as required. ( dsr no. 1.10.3 group c ) 2 supply and fixing suitable size gi box with modular plate and cover in front on surface or in recess , including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. ( dsr no. 1.32 ) 3 wiring for circuit / submain wiring along with earth wire with the following size of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x1.5 sq. mm +1x1.5 sq. mm earth wire. ( dsr no. 1.14.1 ) 4 wiring for circuit / submain wiring along with earth wire with the following size of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. ( dsr no. 1.14.2 ) 5 wiring for circuit / submain wiring along with earth wire with the following size of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.2x4 sq. mm +1x4 sq. mm earth wire . ( dsr no.1.14.3 ) 6 wiring for circuit / submain wiring along with earth wire with the following size of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. ( dsr no. 1.14.10 ) 7 supply and fixing 4 way ( 4+12 ) , double door, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnetions , powder painted including earthing etc. as required. ( dsr no. 2.4.1 ) 8 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole ( dsr no. 2.10.1 ) 9 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5sq.mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. djb sor item code:31.45 10 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. dsr no. 1.25 11 installation , testing and commissioning of pre wired, florescent fitting / compact florescent fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. ( dsr no. 1.41 ) 12 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. upto 450mm sweep. dsr. 1.50.1 13 supply of 1200 mm ceiling fan. make: crompton / havells / philips / djb approved make. djb sor 20.1.2 14 supply of heavy duty exhaust fan of 1440 rpm 450 mm. djb sor 20.2.3 15 supply of heavy duty air circulator 600 mm. djb sor 20.3.2 16 supply of led batten 36 watt in aluminium body construction. make: crompton / havells / philips / djb approved make. djb sor 19.3.3 17 supply of new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminum housing with high efficient led as lighting source and pc cover having top opening separate driver compartment with ip66 protection and impact resistance of ik07 72 watt. djb sor item code: 19.10.6. make: havells, philips, bajaj, crompton, djb approved make 18 supply of c series mcb 63 amp. tpn 10ka, c curve 240 / 415 v, 50hz. ( make havells / c&s / l&t ) ....

Delhi Transco Limited - Delhi

33727090 tender for replacement of damaged/broken earth wire (tower no. 3 to tower no. 4) at 220kv maharani bagh gazipur ckt 1 transmission line under sr. mgr (t) o&m e 5....

Public Works Department - Delhi

33708125 annual repair and maintenance of various electrical installation and mechanical equipments of 119 type iii, residential quarters for the staff of gnctd of delhi at sector 11, rohini, delhi. 2 ) repair maintenance of ei an fans, pumpset, dg set, street light in division office and circle office sub head i ( maintenance of ei & fans at residential staff quarters at sector 11, rohini ) running maintenance and operation of all ei wiring, light points / fan points / exhaust fan points / call bell points, light / power plug points, ac points, edb, main board, street light points, glow sign boards, fl. fittings, ceiling fans, exhaust fans, brass batten / angle holder, call bells, buzzer etc. and operation of drinking and horticulture water pump sets by deputing the following experience staff including sunday and holidays as per terms and conditions attached.staff engaged by the contractora ) wireman cum operator : 02 nos. in ( one no. in each shifts, 6 am to 2 pm & 2 pm to 10 pm ) b ) khallasi : 02 nos. in ( one no. in each shifts, 6 am to 2 pm & 2 pm to 10 pm ) 2 sub head ii ( maintenance of ei & fans at pwd offices at below isbt flyover ) maintenance and upkeeping of all the internal electrical installations, pumpsets including compound lights and recording and monitoring of the complaints including cleaning of all ei and fans etc., operation of water cooled 25 kva dg set manually operated battery charger on all working days ( excluding sundays & holidays ) in general shift complete as per terms and conditions, detail of staff etc as required.staff engaged by the contractora ) wireman cum operator : 01 no. in general shift 3 supplying of following electrical accessories ( i / c dismantling ) suitable for existing different type fitting / switch box etc. for dispensing complaints on day to day basisas required . ( excluding labour cost which is already included in item 1&2 ) a ) s.p. 5 / 6 a, one way switch, piano type isi marked 4 b ) s.p. 15 / 16 a, one way switch, piano type isi marked 5 c ) 6 pin 15 / 16 & 5 / 6 a socket outlet, piano type isi marked 6 d ) piano type electronic fan regulator socket type 7 e ) ell push, piano type 8 f ) call bell / buzzer, single phase 9 g ) 2.5 mfd capacitor 10 h ) 3.15 mfd capacitor 11 i ) s.p. 5 / 6 a, one way modular switch, isi marked 12 j ) 3 pin 5 / 6 a modular socket outlet, isi marked 13 k ) s.p. 15 / 16 a, one way modular switch, isi marked 14 l ) 6 pin 15 / 16 a modular socket outlet, isi marked 15 m ) modular base & cover plate for 3 module 16 n ) vc batten / angle holder 17 o ) 3 mm thick phenolic laminated sheet 18 p ) 1.5 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 19 q ) 4.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 20 r ) 10 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 21 s ) 4x16 sq.mm aluminium conductor armoured cable 22 t ) 4x35 sq.mm aluminium conductor armoured cable 23 u ) 6 a to 32 a ratings, sp mcb, “c” curve, 10 ka breaking capacity 24 v ) 6 a to 32 a ratings, dp mcb, “c” curve, 10 ka breaking capacity 25 w ) 63 a dp mcb c curve 10 ka breaking capacity 26 x ) 63 a rating, 2 pole rccb, 30 ma 27 y ) 63 a fp mcb c curve 10 ka breaking capacity 28 z ) 4 pole mccb, 100a, 30ka 29 aa ) 4 pole mccb, 200a, 36ka 30 ab ) 225 / 230 mm sweepmetallic grey1400 rpm exhaust fan 31 ac ) 300 mm metallic grey 1400 rpm exhaust fan 32 ad ) 1200 mm sweep ( aluminium body ) ac ceiling fan without regulator 33 supplying of following ratings led fittings of colour temperature 6500k with minimum efficacy of 100 lumens / was follows: a ) 12 w led surface mounted round shaped downlighter 34 b ) 20 w led batten fititng 4 feet long surface mounted 35 c ) 36 w / 40 w led batten fitting 36 d ) 30 w led flood light ip65 37 e ) 70 w led flood light ip 65 38 f ) 30 w led street light ip 65 39 g ) 70 w led street light ip 65 40 h ) 200 w led flood light ip 65 41 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc.as required ( group b ) 42 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable and 1.5 sq. mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required. ( group b ) ...

Delhi Tourism And Transportation Development Corporation Limited - Delhi

33692526 providing power distribution, fire safety facilities for server room at 14 locations and other minor e & m associate works 1 wiring for circuit / submain wiring alongwith earth wire with the followingsizesoffrlspvcinsulatedcopperconductor, singlecore cable in surface / recessed medium class pvc conduit as required. ( 2 x 10 sq. mm + 1 x 6 sq. mm earth wire ) 2 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 3 3 x 1.5 sq. mm 4 3 x 2.5 sq. mm 5 6 x 2.5 sq. mm 6 6 x 4 sq. mm 7 supplying andfixing offollowing sizes ofmedium class pvc conduit along withaccessoriesinsurface / recessincludingcutting thewalland making good the same in case of recessed conduit as required. 8 25 mm 9 32 mm 10 supplying andfixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 11 5 / 6 a switch 12 3 pin 5 / 6 a socket outlet 13 15 / 16 a switch 14 6 pin 15 / 16 a socket outlet 15 supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. 16 1 or 2 module 17 6 module 18 supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface / recessed steel / pvc conduit as required. 19 1 run of cable 20 2 run of cable 21 3 run of cable 22 earthing with g.i. earth plate 600mm x 600mm x 6mm thick including accesssories, and providingmasonary enclosurewith cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required. ( for body earthing of euipment ) 23 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe fromearthelectrodeincludingconnectionwithg.i.nut, bolt, spring, washer excavation and re filling etc. as required. 24 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 25 providingandfixing6swgdiag.i.wireonsurfaceorinrecessfor loopearthingalongwithexistingsurface / recessedconduit / submain wiring / cable as required. 26 supplyingandfixing of60x45mmpvccasing along withcapping on the surface complete etc. as required. 27 supplying and fixing of 100x100mm pvc casing along with capping on the surface complete etc. as required. 28 designing , supplying, installation, testing & commissioning of outdoor type ( ip 65 ) electrical panels, cubicle type, made out of 2 mm thick 14 swg crca sheet, totally enclosed, free standing, floor / wall mounting, dust and vermin proof, indoor type , compartmentalised, front openable double door with lock arrangement , suitable eartthing link , suitable for operation on 3 phase and neutral, 415 v, 50hz ac system with suitablebusbars, including internal wiring with suitable size of wires / cables, interconnection, duly powder coated painting with 7 process etwith earth bus and lifting hooks as requiredin case of large panelsincluding supplying & installation of suitable stand with angle frame size 40 mm x 40 mm x 5 mm ( 400 mm long ) of following switchgears, therein, and accessories as per specifications & prior approval shall be taken for each panel before fabrication as per approved drawing by engineer in charge. ( all hardwares like nuts and boltsused shall be galvanized and zinc passivated ) minimum panel depth is 250 mm.face area of panel 2.0 sq. mm 29 incomer: a ) 2 no. 125 a 4 pole 4mccb , 36 kawith contractor tm releasecontrollerhaving adjustable o / i , s / c protection and extended roatary handle ans spreder link for incoming source i & ii & all acessoriesautomatic change over switch ( atys ) b ) 1 no. 63 a 4 pole 415 v , , ats with controller & all acessoriesmetering & indication: a ) 2 set of r, y, b phase indicating lamps with 6 a , 10 ka , mcbb ) 1 nos. digital type multi function meters ( a+v+kwh+kvar+ f+ pf+kva ) with castresin cts 150 / 5a , class 1bus bar:a ) 1 set of 150 tpn aluminium bus bar with colour coded pvc sleeves 30 outgoings: a ) 1 nos , 100 a, 4p, 36 ka, mccb with extended rotary handle and spreder linkb ) 1 nos , 63 a, 4p, 10 ka, mccb with extended rotary handle and spreder linkc ) 4 nos , 32 / 40 a, dp, 10ka, mcb d ) 2 nos , 40 a, tpn, 10ka, mcb one complete set 31 supplyingof one no. xlpe insulated pvc sheathed armoured power cable with aluminium conductor armouredof 1.1 kv grade of size of 3½ x 35 sq. mm by following methods: 32 supplying and making end termination with brass compression gland and aluminium lugs for following sizes of xlpe insulated pvc sheathed armoured power cable aluminium conductor cable of 1.1 kv gradeetc complete as required. 3½ x 35 sq. mm 33 laying of one number additional pvc insulated and pvcsheathed / xlpe power cable of 1.1 kv grade of following sizedirect in ground in the same trench in one tier horizontalformation including excavation, sand cushioning, protectivecovering and refilling the trench etc as required. upto 35 sq. mm 34 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal pipe as required upto 35 sq. mm 35 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm 36 laying and fixing of one number pvc insulated and pvc sheathed i xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thick saddle ) 37 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required 38 supplying and fixing pvc insulated and fr pvc round sheathed, copper conductor ( flexible ) industrial cable, 1100 volt, conforming to is 694 wire following sizei / c connections, testing etc.completeas required 4 core x 10 sq.mm 39 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 4 way ( 4 + 12 ) , double door 40 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 41 double pole 42 triple pole and neutral 43 supplying and fixing 32 a / 40 a, 240 v, spn industrial type socketoutlet ( male female type ) with 2 pole and earth, metal enclosed plug topalongwith 32 a / 40 a, c curve, dp, mcb, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the male female socket outlet and complete with connections, testing and commissioningetc. as required. 44 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 45 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 46 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 47 supply, installation, testing and commissioning of 2.0 lb capacity novec 1230 fire suppression systems with 3m novec 1230 fire protection fluid, dlp assembly with automatic valve, push in connector for tube, 2.5 lb novec 1230 gas , mounting bracket, end of line adopter and low pressure switch for monitoring system activation etc. as required. 48 supply, installation, testing and commissioning of linear pneumatic heat detection tube with all necessary fittings & supports etc. as required. 49 supply, installation, testing and commissioning of master control unit with audio visual alarm with wiring to make complete system operational . thecontrol panel should have provision for integration with fire alarm etc. as required....

Public Works Department - Delhi

33625107 renovation work of internal electrical installation at commercial shop no. 33 allotted by pwd, gnctd for central homeopathic drug store, gnctd at gulabi bagh, delhi. ( sh: providing iei & fans, ro water cooler, cctv, air conditioning & safety equipments etc. ) wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor singlecore cable etc. as required. ( a ) group c 2 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 3 wiring for light / power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 4 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.a ) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 5 b ) 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 6 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required.a ) 2 pair 7 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 8 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a ) 20 mm 9 b ) 25 mm 10 c ) 32 mm 11 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a ) 15 / 16 a switch 12 b ) 3 pin 5 / 6 a socket outlet 13 c ) 6 pin 15 / 16 a socket outlet 14 d ) telephone socket outlet 15 e ) tv antenna socket outlet 16 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 17 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required.a ) 1 or 2 module ( 75 mmx75 mm ) 18 b ) 8 module ( 125 mmx125 mm ) 19 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modular switch, connections etc. as required. 20 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 a & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 21 supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box / wooden block including connections etc. as required. 22 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) a ) 8 way ( 4 + 24 ) , double door 23 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.a ) single pole 24 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.a ) 100 a 25 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. 26 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cmm / w ) minimum 6.85, air delivery minimum 215 cmm, 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 27 supplying and installation of single phase heavy duty exhaust fan alongwith aluminium louvers of 300 mm sweep 900 rpm in the existing opening, making good the damage, connection testing commissioning etc as reqd. 28 supplying installation, testing and commissioning of wall mouted bracket fan sweep 400 mm sweep, pvc body with air delivery not less than 80 cmm and of 1300 rpm, including remote speed control complete with all accessories connection etc. as required. 29 supplying, installation, testing and commissioning of 9 12 watts, led batten with integrated electronic driver for mirror light having lumens output = 900 lumens = 900 lumens , luminuous efficacy = 100 lumen / watt complete with all accessories etc.directly on wall / ceiling including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 30 supplying, installation, testing and commissioning of 34 36 watts 2x2 feet led surface light fabricated crca sheet steel housing duly powder coated with high efficient led surface mounted luminaire having 100 luminaire per watt, cct 5700k to 6500k, power factor >0.90 , cri > 70% ( including dismantling the old fitting if any ) complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 31 supplying, installation, testing and commissioning of surface / wall mounted 1x 20 22 led tube with 4ft ms batten fitting, led tube should have polycarbonate housing & lamp having minimum 100lumens per watt.cct 5700k to 6500k, power factor>0.90, cri > 70% ( including dismantling the old fitting if any wherever reqd. ) complete with all accessories etc.including making connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required.a ) 20 22 watts tube with t 8 polycarbonate led tube light 32 supplying, installation, testing and commissioning of 15 watts, round shape led surface type downlighter complete with all accessories etc. directly on ceiling including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required 33 supplying, installation, testing & commissioning of 80 watts pdc aluminium body, ip66 led flood light fitting with lens & toughened glass capable of delivering following nominal system lumens output with a minimum system efficacy more than 110 lumens / watt and a cri greater than 70 . the luminaire shall have a life class of 50000 hours @l70 for a design ambient of 35 deg c . the inbuilt electronic driver shall operate at power factor > .95 of cct 5700k minimum internal surge protection of 4 kv with toughened glass / polycarbonate cover lm 79 / 80 certification to be provided by the manufacturer for led luminaire / led chip .complete with all accessories i / c making connections, testing & suitable size bracket for fixing i / c dismantling the existing fitting etc. complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 34 sitc of energy efficient 5 star rated wall mounted split type ac unit 1.8 / 2 tr capacity inverter type suitable for operation on single phase, 220v, 50hz, ac supply i / c electronic remote control, comprising of both indoor and outdoor unit with rotary compressor duly filled with suitable ecofriendly refrigerant r 32 / r 410, ms angle iron stand for outdoor, 6 meter length. 4core 2.5 sq mm wire, 4 mtr. copper tube of suitable size, wall thickness 0.8mm duly insulated with 9mm nitrile insulation, 5 mtr. pvc drain pipe of size 25mm i / c elbow, tee, socket, cement solvent etc. complete as reqd. 35 supplying, installation, testing & commissioning of 900 va pure sine wave inverter, having led display for status of power backup / battery charging time in hours and minute ( noiseless ) operation alongwith2 nos. 150 ah batterywith connection etc complete as required. 36 sitc of 50 lph capcity fully automatic with auto cut off reverse osmosis ( ro ) potable water purification system having 6 stage purification, power consumption =120 watt and suitable for operation on 230 volts± 10%, 50 hz, . ac supply including water inlet & outlet connection etc. as required. 37 s.i.t.c. of self contained drinking water cooler in stainless steel body complete with refrigerant r 22, cooling capacity 150 ltr. / hr. storage type of capacity 150 ltr., max. energy consumption: 1500 watt, suitable for operation on 230 volts + 10%, 50 hz, . ac supply including fixing on angle iron frame work stand of size 35mm x 35mm x 5mm thick suitable height including water inlet & outlet connection etc. as required. 38 sitc of 5 mpx ir ip varifocal bullet camera with poe, 1920 x 1080 at 25 / 30fps, 1 / 2.9cmos, lens 3.5 9mm, auto focus and zoom, h.265, h.264 compression, smart compression, ir range 50 meter, 120db true wdr, triple streaming, motion detection, camera sabotage, ip66, ik10 housing, camera shall support sd card 128 gb, onvif profile s, g, & t compliant, operating temp upto +55deg, ul / iec / en / bis certified complete etc. as required. 39 sitc of 5 mpx ir ip verifocal dome camera with poe at 1920 x 1080p at 25 / 30fps, 1 / 2.9cmos, lens 3.6mm, auto focus, h.265 / h.265+ smart compression, ir range 30 meters, 120db true wdr, built in microphone, triple streaming, motion detection, camera sabotage, ip66, ik10 housing, camera shall support sd card 128gb, onvif profile s, g, &t compliant, temp upto +55deg, ul / iec / en / bis complete etc. as required. 40 sitcof 8 ch network video recorder with 8 sata drives supported, upto 64tb of storage supported, server / linux based, multi streaming option, upto 12mp resolution supported, raid enabled, real time playback of 16 channels at single time complete etc. as required. 41 sitc of 8 port poe network switch with 2 sfp+ ports, loaded with sfp module complete etc. as required. 42 sitc of 8tb surveillance hard disk complete etc. as required 43 supply and laying of cat 6 utp 4 pair ethernet cable in existing conduit complete etc. as required.a ) 1 run of cable 44 supplying, installation, testing & commissioning of 43 ultra hd 4k smart led tv having wi fi, 2160 pixels, 20 watt speaker output, hdmi, usb, ethernet including providing and fixing company supplied bracket on wall complete etc as reqd. 45 providing, installation, testing and commissioning of isi marked co2 type fire extinguisher of 4.5 kg capacity consisting of seamless cylinder, complete with delivary hose horn, squeeze grip release valve, locking arrangement etc completeconforming to is:15683:2006 duly charged with co2 including carrying handle and wall bracket etc. complete with up to date test certificate as required. 46 providing, installation, testing and commissioning of isi marked abc stored pressure type fire extinguisher of 6 kg capacity consisting of welded cylinder, squeeze lever discharge valve fitting with pressure indicating gauge with internal discharge tube, discharge nozzle, suspension bracket conforming to is:15683:2006 duly charged, with is marked mono ammonium phosphate base abc powder conforming to is:14609 charged with purged water and pressurized with nitrogen gas etc. as required. 47 add cost index @ 34.95% on dsr 2016 ( item no. 1 to 17 ) rs. 48 less 9.5% on total value of dsr 16 & 19 ( items no. 1 to 18 ) i / c cost index rs. 49 total value of market rate and dsr item after deduction of 9.5 %= 1224372...

Military Engineer Services - Delhi

33380437 repair / maintenance of summer appliances window type / split type / cassatte type acs and allied services at kashmir house under ge new delhi 1 labour for checking and attending complaints of acs, refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed. ( any parts required forreplacementshall be measured and paid separately under respective items ) notes: ( a ) the contractor should detail minimum one ac mechanic & one helper to attend complaints in kashmir house . ( b ) the complaint should be attended on same day with in 3 hours . ( c ) ) if the complaint not attended / not completed on same daywith in three hours recovery will be done as follows: ( i ) for first day rs.1000 / ( ii ) for second day rs.1500 / ( iii ) for nextevery day rs.2000 / 2 servicing of window type ac 1.5 / 2 ton capacity ofany make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checkingof electric circuit for smooth functioning of ac 3 all as per item no 2 above but split type ac of any type and 1.5 / 2 ton capacity 4 servicing of three phase cassette / tower type split ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified. note: unserviceable spares parts required to be replaced shall be measured and paid separately under respective items. 5 supply only against repairs running capacitor combination ( 50 mfd + 6 ) / ( 50+4 ) mfd 230 voltfor ac upto 4.00 ton . 6 supply only in replacementrunning capacitor 6 mfd 230 volt 7 supply only in replacementrunning capacitor 4 mfd 230 volt 8 supply & charging gas refrigerant r 22 / 410 a / or as existing to window type / split type / cassette / package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer in charge 9 supply onlyin replacementstarting relay suitable for 1.5 / 2 ton capacity ac 10 supply onlyin replacementover load protector suitable for 1.5 ton capacity ac 11 supply onlyin replacement thermostat switch suitable for 1.5 / 2 ton capacity ac 12 supply only against in repair item ofstarting relay suitable for 4.0 ton capacity ac complete all as specified. 13 supply only against in repair item ofover load protector suitable for 4.0 ton capacity ac complete all as specified. 14 supply only against in repair item ofthermostat switch suitable for 4.0 ton capacity ac complete all as specified. 15 supply and fixingin replacementreciprocating / rotary type compressor suitable for 1.5 to 2.0ton capacity split type ac of the same make and model as per existing make of acs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed. 16 supply and fixingin replacementreciprocating / rotarytype compressor suitable for 1.5 to 2 ton capacitywindow type ac of thesame make and model as per existing make of acs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed. 17 supply and fixingin replacementany type of compressor suitable for inverter type 1.5 to 2 ton capacitysplitac of thesame make and model as per existing make of acs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed. 18 supply and fixingin replacement ofthree phase compressor suitable for 3.5 to 4.0 ton capacity suitable of cassette / tower acof the same make and model as per existing make of acs complete all as specified and directed. 19 supply onlyin replacement wiring kit suitable for 1.5 / 2 ton capacity ac complete all as specified & directed 20 supply only in replacement air filter synthetic / nylon as per existing size and shape suitable for 1.5 / 2 ton capacity window type acs 21 supply only in replacement air filter synthetic / nylon as per existing size and shape suitable for 1.5 / 2 ton capacity split type acs 22 supply only against in repair item ofair filter synthetic / nylon type as per existing size and shape suitable for 3.5 / 4.0 ton capacity cassette type split acs complete all as specified. 23 supply only in replacement new fan motor ( indoor / outdoor ) 1 / 4, 1 / 5 hp single / double shaft as per existing model suitable for splittype acs 1.5 / 2 ton complete all as specified and directed. 24 supply only in replacementnew dc fan motor ( indoor / outdoor ) 1 / 4, 1 / 5 hp single / double shaftas per existing model suitable for splittype acs 1.5 / 2 ton complete all as specified and directed. 25 supply only against in repairoffan motor single / double shaft as per existing model suitable for 3.5 / 4.0 ton acs of any make / type complete as per requirement on site all as specified. 26 supply only against in ofnew dcfan motor single / double shaft as per existing model suitable for 3.5 / 4.0 ton cassette typeacs of any make / type complete as per requirement on site all as specified. 27 m & lfor rewinding of fan motor suitable for acs up to 4 ton capacity with super enamelled copper winding wire of same gauge including replacement of insulating material, bushes and shaft all as specified & directed 28 supply onlyin replacement pvc insulatedflexible copper conductor 3 core 1100v grade of size 2.5 sqmm. 29 supply onlyin replacement pvc insulatedflexible copper conductor 3 core 1100v grade of size 4.0 sqmm. 30 supply onlyin replacementcondenser fan blade made out ofplastic suitable for upto 2 ton capacity window type acs. 31 supply onlyin replacementcondenser fan blade made out ofplastic suitable for upto 2 ton capacity split type acs. 32 supply only against in repairofcondenser fan blade made out of aluminium suitable for upto 4.0 ton capacity cassette type split acs complete all as specified & directed. 33 supply onlyin replacement of evaporatingair blower made out ofsuitable for upto 2 ton capacity for window type ac all as specified and directed 34 supply onlyin replacement of evaporatingair blower made out of suitable for upto 2 ton capacity for split type ac all as specified and directed 35 supply only against in repairofindoor air blower made out ofsuitable for upto 4.0 ton capacitytype split acs complete all as specified & directed. 36 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 6.0 mm ( 1 / 4 ) for refrigerant copper piping of split ac units. 37 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 13.0 mm ( 1 / 2 ) for refrigerant copper piping of split ac units. 38 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 9 mm ( 3 / 8 ) for refrigerant copper piping of split ac units.make: supreme / gulf o flex / superlon. 39 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 16 mm ( 5 / 8 ) for refrigerant copper piping of split ac units.make: supreme / gulf o flex / superlon. 40 m & l for replacement of front grill suitable for window type acs upto 2 ton capacity of any make as per existing size and shape. 41 m & l for replacement of reverse valve system suitable to 1.5 / 2 ton split / window ac for heating option. ( gas charging shall be paid and measured under respective item ) 42 supply onlycopper tubing heavy duty inner dia 6 mm ( 1 / 4 ) for refrigerant for acs. make mandev / mandley / uniflow 43 supply onlycopper tubing heavy duty inner dia 13mm ( 1 / 2 ) for refrigerant for acs. 44 supply onlycopper tubing heavy duty inner dia 9 mm ( 3 / 8 ) for refrigerant for acs. 45 supply onlycopper tubing heavy duty inner dia 16 mm ( 5 / 8 ) for refrigerant for acs. 46 supply onlycondensing coil suitable for 1.5 / 2 ton splittype acs as per existing size / shape and as per existing make. 47 supply onlyevaporating coil suitable for 1.5 / 2 ton splittype acs as per existing size / shape and as per existing make. 48 supply onlybrass flare nut / connector heavy duty of size 6 mm / 9 mm ( 1 / 4, 1 / 2 ) as per existing make. 49 repair to control processing board ( remote control kit ) with hand set including replacement of current transformer, ics, diodes, resistances, sensors etc complete for 1.5 / 2 ton split type acs of any make & model. 50 repair to control processing board ( remote control kit ) inverter typewith hand set including replacement of current transformer, ics, diodes, resistances, sensors etc complete for 3.5 / 4 ton split type acs of any make & model. 51 supply and fixingin replacement split type ac 1.5 / 2 tonindoorunit kitwithpcb complete withsensor complete with fixing plate suitable to non inverter type ac complete all as specified and directed. 52 supply and fixingin replacement split type ac 1.5 / 2 tonindoorpcb unit kitcomplete withsensor complete with fixing plate suitable to inverter typemodel and make ac all as specified and directed. 53 supply and fixingin replacement split type ac 1.5 / 2 ton outdoor unit kit complete with compressor, condensor coil, condenser fan with blade and sensor suitable to non inverter typeexisting model and make ac all as specified and directed. 54 supply and fixingin replacement split type ac 1.5 / 2 ton outdoor unit kit complete with compressor, condenser coil, condenser fan with blade and sensor suitable toinverter typeexisting model and make ac all as specified and directed.make: carrier / blue star / napolean / totaline. 55 supply and fixingin replacement window ac kit 1.5 / 2 tonpcbwith sensorcomplete with condensing coil, fan motor, blower and motor, compressor and grill complete suitable to non inverter type existing model and make ac all as specified and directed.make: carrier / napolean / skoda. 56 supply only in replacementair direction changer louver motor ( swing motor ) suitable for split type acs as per existing make and model 57 supply only in replacement cordless remote for inverter type acshot & cool suitable for 1.5 ton ac as per sample. 58 supply onlyin replacement cordless remote for acssuitable for 1.5 / 2 tonsplit / windowac as per sample. 59 servicing of refrigerators of 165 to 310 ltrcapacitysingle door ofany make / model by cleaning of condensing coil with wire & brush to remove dust includingcheckingof electric circuit for smooth functioning complete all as specified and directed by engr in charge 60 supply and fixingin replacementnew compressor suitable for 165 / 310ltr capacity refrigerator reciprocating type complete all as specified and directed. 61 supply and fixingof monkey menace protection device with pvc spikes size as per sample all as specified and directed 62 taking down ac of any type, any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repairwork, transportation back to location of installation , reinstallation / refixing in position after complete repairs as required and making functional includingtesting complete all as specified and directed. 63 supply and fix of drain pipe of any size suitable for split ac of capacity 1.5 / 2 / 3.5 / 4 tr as per sample all as specified and directed 64 m&l in replacement metalclad plug & socket board sp&n enclosure with single pole and earth metal plug & socket suitable for 20 amps mcb ac, 220 v, 50hz . 65 m&l in replacement modular acboard sp&n enclosure with single pole and earth metal plug & socket suitable for 20 amps mcb ac, 220 v, 50hz 66 supply, installing, testing and commissioning in replacement factory made and tested outdoor type, platform mounted, phase sequence corrector of capacity 63 a , 3 phase 4 wire, 415 volts, 50 hz, platform mounted. the phase sequence corrector shall be dust and vermin proof, protection class ( ip 54 ) and made of 2.00 mm thick stainless steel sheet 316l thick & suitable frame work / support made out of 75 mm stainless steel flat channel, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with pvc insulated multistranded copper conductor frls cable of adequate size but not less than 1.5 sqmm complete. the scope of work also comprising of the following: make: havells / schneider / abb / l&t / universal switch gear control. note work includes civil work like excavation and preparation of pcc plinth 67 phase sequence corrector of capacity 63 a , 3 phase 4 wire, 415 volts, 50 hz with facility to change over from automatic to manual, microprocessor release ( over load, short circuit, instantaneous single phasing, phase reversal ) , pre trip alarm and individual fault indication led with fully rated neutral with inbuilt protection. the over load release shall be adjustable type, protection: avoid damages during phase sequence changes or reversal.• the sequence corrector will switch off, during the single phasing or imbalance voltage occur & later, auto reset after restoration.• no break downs of three phase system due to the change in sequence.• bye pass selector switch in case of controller faulty. 68 the panel manufacturer should have following govt. approved certificates: 1. cpri certification degree of protection ip 542. cpri certification short circuit withstand strength should be 50karms for 1.0 sec with initial peak of 105ka 3. cpri certification rated current for short circuit not less than 4000a with rated insulation voltage 660v4. iso 9001 certified 69 supply, install, commissioning and testing in replacement of lt panel board outdoor type floor mounted of factory made powder coated made out of outside body of 2.00 mm thick stainless steel sheet 316l thick & suitable frame work / support made out of 75 mm stainless steel flat channel, , locking arrangement, front side and rear side opening arrangement of suitable size, incl mounting onduly grouting or welded on floor. aluminium bus bar tpn of 600 a for mccb to all feeders to accommodate following items: ( a ) incoming mccb 250 amp 50 ka 4 pole, microprocessor based energy release 01 no cat no hmt250nr hageurs, equivalent in legrand / schneider ( b ) outgoing mccb 100 amp 40 ka 3pole, microprocessor based energy release 04 no hns100 nr ( c ) ryb indication for each incoming & outgoing supplies 01 set ( d ) voltmeter, amp meter, digital type with ct’s &selector switch 01 set ( e ) termination of all cables with suitable size thimble and gland 1job ( f ) termination of all cables with suitable size thimble and gland 1 job . make for ss enclosure : havells / schneider / abb / l&t / universal switch gear control. note work includes civil work like excavation and preparation of pcc plinth 70 supply, install, commissioning and testing in replacement of lt panel board indoor type floor mounted of factory made powder coated made out of outside body of 2.00 mm thick stainless steel sheet 316l thick & suitable frame work / support made out of 75 mm stainless steel flat channel, locking arrangement, front side and rear side opening arrangement of suitable size, incl mounting onduly grouted or welded on floor. aluminium bus bar tpn of 600 a for mccb to all feeders to accommodate following items: ( a ) incoming mccb 200 amp 50 ka 4 pole, microprocessor based energy release 01 no.cat no hmt250nr haguer, equivalent in legrand / schneider ( b ) outgoing mccb 100 amp 40 ka 3pole 04 no microprocessor based energy release 01 no.cat no hns100nr hager, equivalent in legrand / schneider ( c ) changeover on load for open execution 200 amp ( d ) ryb indication for each incoming & outgoing supplies 01 set ( e ) voltmeter, amp meter, digital type with ct’s &selector switch 01 set ( f ) termination of all cables with suitable size thimble and gland 1job ( g ) termination of all cables with suitable size thimble and gland 1 job . make for ss enclosure : havells / schneider / abb / l&t / universal switch gear control . note work includes civil work like excavation and preparation of pcc plinth 71 supply only in replacement voltage stabilizer of capacity 3 to 5 kva , copper wounded made of metallic steel body complete all as specified and directed 72 s&f in replacement of plug top3 pin, 15 amps, 230 volts, 50 hz ac complete all as specified. 73 m&l for taking down split / window ac and shifting from one position to other within the premises complete with copper tubing indoor plate and copper tubing complete with all accessories with making good the disturbed surfaces with cement plaster and pop . complete all as specified and as directed by engr in charge 74 s&f sub main wiring in replacement with two runs pvc insulated unsheathed frls stranded copper conductor cable of size4.0 sqmm along with one run of pvc insulated unsheathed stranded copper conductor cable of size 2.5 sqmm as earth wire connected to earth dollyfixed on surface of wall / ceiling / in concealed pvcconduits complete including cutting chases and making good to walls at disturbed area all as specified and directed. make of conduit plaza / kalingamake of cable rr kabel / havells / polycabnote : two run of 4.0 sqmm copper conductor cable, one run of 2.5 sqmm copper cable and one run of pvc conduit shall be measured as one unit length 75 all as per item no 74 here in before but size of cable 2 x6sqmmcomplete along with cable 1x2.5 sqmm frls type for continuous earth wire and connected to common earth dolly complete all as specified.make rr / havells / polycabnote : two run of4 sqmm copper conductor cable, one run of 2.5 sqmm copper cable and one run of pvc conduit shall be measured as one unit length 76 supply only in replacement of factory made load line dbs double door made out of crca mild steel sheet with insulating materials like polyester epoxy coated surface mounting 12 way tpn 415 volts, ip 43 with suitable busbar, neutral link & earth link suitable for mccb tp as incomer & mcb sp / tp as out going complete all as specified 77 supply only in replacement of factory made load line dbs double door made out of crca mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way tpn 415 volts, ip 43 with suitable busbar, neutral link & earth link suitable for mccb tp as incomer & mcb sp / tp as out going complete all as specified. 78 supply only in replacement of mccb tp / tpn125 amp, 25ka thermal type complete all as specified. 79 supply only in replacement of mccb tp / tpn 160 amp, 25ka thermal type complete all as specified. 80 supply only in replacement of mcb sp 40 63 amp, 10ka all as specified. 81 supply & fixed rigid non metallic 20 mm external dia pvc conduit concealed on surface to wall / ceiling for drain out of water from split type and window typebut inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks up to outdoor unit to ground floor level all directed by engr in charge. 82 supply only in replacement flexible pipe 15 / 20 / 25 mm dia white colour complete all as specified and directed 83 supply only in replacement of mcb spn 20 32 amp, 10ka all as specified. 84 m & l for making suitable hole in the wall to fix window or split ac and maintain the surface as per existing note : ( a ) plastering , putty , painting included in the quoted rate . ( b ) covering the window by ply if necessary also included in the quoted rate 85 supply only in replacement wall stand / chauki stand to fix outdoor of split / cassette ac made ofmetallic stell complete all as specified and directed 86 supply only in replacement fastener upto 8mm size suitable to fix wall stand / chauki stand complete all as specified and directed...

Indian Army - Delhi

33264656 bids are invited for title1 supply and install hi wall slit units indoor outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimun 3 star rating and eer 3.2 of capacity 2.0 title2 supply and install cassette type units indoor / outdoor complete with cordless remote control unit twin rotary compressor single phase units 220v 240v 50 hz of capacity 3.0 tr title3 supply and fix voltage stablizer for automatic operation single phase naturally air cooled indoor type & designed for input variation 170v to 250v with accuracy 2.5% and of capacity 5 kva title4 m&l for sheet metal enclosures with plug top and mcbs single pole and natural enclosures with two pin and earth plug and socket complete with one single pole mcb 32a capacity all as per directed title5 m&l for sheet metal enclosures with plug top and mcbs single pole and natural enclosures with two pin and earth plug and socket complete with one double pole mcb 63 a capacity all as per directed title6 m&l for submain wiring along with earth wire with the 2x4.0 sqmm+4.0sq mm earth wire of fr lsh pvc insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories complete all as required or all as specified and as directed by engr in charge title7 m&l for submain wiring along with earth wire with the 2x10.0 sqmm+10.0 sq mm earth wire of fr lsh pvc insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories complete all as required or all as specified and as directed by engr in charge title8 s & f in replacement of electrolyte garade copper tubing of size 3 / 8 suitable type split type ac including synthetic rbber foam complete all as specifed and directed. title9 all item no 08 here in before but size 5 / 8 complete all specified directed total quantity : 414...

Delhi Jal Board - Delhi

33175584 renovation / improvement of internal and external lighting system for various jal suvidha kendra under bottling plant greater kailash i ( ac 50 ) . , s / o 20 w led batten light. make: bajaj / havells / crompton , s / o 70 w led street light. make: bajaj / havells / crompton , s / o 450 mm size exhaust fan. make: havells / orient / crompton , s / o 1200 mm size ceiling fan. make havells / orient / crompton , s / o led fitting and frame 600mm x 600 mm ( n.s ) with het diffuser, recess mounting 36 watt. make philips / havells / bajaj / crompton , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 10 sq.mm 2 core armored cable. make: havells / grandley / gloster / any djb approved make. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenol laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, includes wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. , supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally used where 3 phase outlets are required. ) 8way, double door ( 4+24 ) . , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way, double door. , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole 2.10.1 , supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. 63 ampdouble pole. , supplying and fixing following rating, four pole, ( three phase and neutral ) , 415 volts, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. , earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Delhi Transport Infrastructure Development Corporation Limited - Delhi

33100754 upgradation of copa lab. in lala hans raj, iti narela, delhi under imc fundsh: elecrtrical work ) 1 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable size gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required (dsr 2016)a)group c 2 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required (dsr 2016) 3 wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required.(dsr 2016) 4 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as requireda) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (dsr 2016) 5 b) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wir e(dsr 2016) 6 c)4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire (dsr 2016) 7 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. (dsr 2016) 8 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) (dsr 2016)a) 16 way , double door 9 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. (dsr 2016)a) single pole 10 supplying and fixing following rating, double pole, 240 v/415 v, isolator/mcb in the existing mcb db complete with connections, testing and commissioning etc. as required.a) 63 a (dsr 2016) 11 b) 100 a(4p) (dsr 2016) 12 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (dsr 2016)a) 25 mm 13 supplying and fixing dp sheet steel enclosure on surface/recess along with 25/32 a, 240 v “c” curve dp mcb complete with connections, testing and commissioning etc. as required. (dsr 2016) 14 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required.a) 1 or 2 module (75 mmx75 mm) (dsr 2016) 15 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (dsr 2016) 16 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 3 pin 5/6 a modular socket outlet and 2 nos. 5/ 6 a modular switch, connections etc. as required. (for light plugs to be used in non residential buildings) (dsr 2016) 17 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required (dsr 2016) 18 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, c curve including connections, painting etc. as required.(dsr 2016) 19 supplying and making end termination with brass compression gland and aluminum lugs for following size of pvc insulated and pvc sheathed / xlpe aluminum conductor cable of 1.1 kv grade as required (dsr 2016) a) 2 x 6 sq. mm (19mm) 20 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm (clamped with 1mm thick saddle) (dsr 2016) 21 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required (dsr 2016) 22 supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface/ recessed steel/ pvc conduit as required. (dsr 2016)a) 1 run of cable 23 b) 2 run of cable (dsr 2016) 24 c) 3 run of cable (dsr 2016) 25 supplying ofpvc insulated pvc sheatheredal. conductor, armouned cable 1.1 kv grade of following sizesas reqda) 2x6 sqmm 26 supply & fixing of 2’x 2’size of 36 watt led light panel fittings suitable for operation 220 volts single phase ac supply with the help of chain complete with driver etc. i/c connection,testing etc. as required 27 supplying, installation, testing and commissioning of 1200mm (48”)sweepceiling fan suitable for operation on 220 volts single phase ac supply i/c wiring the down rod of reqd. size with 1.5 sqmm frspvc insulated, copper conductor single core cable etc. as reqd. 28 s/i/t/c of exhaust fan (12”) heavy duty steel body suitable for operation on 220 volts single phase ac supply in the existing opening etc. complete as required 29 supplying, installation, testing and commissioning ofwall mounted inverter split air conditioning unit of 2tr capcity having cooling capacity of not less 24000 btu/hr. with necessary copper piping and cabling (up to 3 meter length),microprocesser controlled indoor unit with with cordless remote controller, outdoor unit with hermaticaly sealed energy effeciantrotary compressor, copper coil condenser suitable for operation on 220/230 v(single phase) ac supply complete as required at site. 30 providing and fixing ms frame of suitable sixe for mounting out door condenser unit of split ac i/c painting etc. completeas required 31 supplying and fixing suction and discharge refrigerent copper pipe line suitable for2 tr capacity split acunit i/cnitrile insulation, brazing etc. completeas required 32 supply, installation, testing and commissioning of 9u rack with pdu strip (5amp) cable manager on the wall with the help of hole fasteners etc 33 supply ,installation ,testing and commissioning of d link/neat gear 48 ports 10/100/1000lanswitch in the existing rack including, connection ,testing etc. asrequired.a) 24 ports 34 b) 8 ports 35 supply and fixing of patch card of following sizes including testing, connection, etc complete as required ( dlink)a) 1 meter 36 s/crimping of rj 45 jack i/c testing etc. as red. (m/s d.link) 37 s/finformation outlet with face plate (d.link make) 38 s/fpatch cord cat 6 (1 mtr) d.link make 39 add 21.46% on dsr items amounting to rs. 105421 40 less 9.50% on dsr items amounting to rs. 128044.35 ...

Delhi Jal Board - Delhi

33011456 electrification of internal lighting system at gulabi bagh b.p.s. 1 dismantling of old wiring, switches, ceiling fans, tube light and fittings mcb and mcb’s box and others old damaged accessories of electric wiring accessories etc. as per site requirement. 2 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface i recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. dsr 2018, item code: 1.1.1 & djb s.o.r. 3 supply/fixing of metal box of 150mm x 75mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing & fixing 3 pin 5/6 amp socket outlet and 5/6 amp piano type switch connection, painting etc. as required (for light plug to be used in non residential building) dsr 2018 code: 1.29 & djb s.o.r. 4 wiring for circuit/sub main wiring along with earth wire with following sizes of pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required:a. 2 x 1.5 sq mm 1 x 1.5 sq mm with earth wire. dsr 2018, item code 1.14.1& djb s.o.r. 5 wiring for circuit/sub main wiring along with earth wire with following sizes of pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required:b. 2 x 2.5 sq mm 1 x 2.5 sq mm with earth wire dsr 2018, item code 1.14.2& djb s.o.r. 6 s/o led light of 45 watt new generation energy saving and environmentally friendly long life led street light made up of pressure die cast aluminum housing with highly efficient led as lighting source and pc cover having top opening separate driver compartment with ip66 protection and impact resistance of ik07. djb s.o.r., make: bajaj, havells and any approved make of djb 7 s/o 20 w led 6000 k decorative ultra slim square profile led lighting fixture with extruded polycarbonate, environmentally friendly, energy efficient ready to use pack. lamp type order. djb s.o.r. make: bajaj, havells, philips 8 s/o of ceiling fan having size 1200 mm (48’) in white colour.djb s.o.r. make: anchor, orient, standard, and any approved make by djb 9 wall mounted air circulator 600mm. djb s.o.r. make: havells/crompton/almonard and any approved make of djb 10 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm frls pvc insulated, copper conductor, single core cable etc. as required. dsr 2018, item code: 1.44, djb s.o.r. 11 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. dsr 2018, item code: 1.25, djb s.o.r. 12 supply/fixing of following way single pole and natural, sheet steel mcb distribution board, 20 volts, on surface/recessed complete with tinned copper bus bar, neutral bus bar, earth bar, din bar detachable gland plate interconnection phosphatized and powder painted including earth etc as required (but without mcb/rccb/isolator) 8 way single door. dsr 2018, item code: 2.3.2, djb s.o.r. 13 supply, 1.1 kv grade, xlpe insulated, stranded aluminum conductor, galvanized steel flat strip / round wire armored, extruded pvc type st2 sheathed, conforming to is:7098 (part 1) & iec:60502 (part 1) of following sizes 3 core x 16 sq.mm djb s.o.r. make: havells, plolycab and any approved make of d.j.b. 14 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm (clamped with 1mm thick saddle) dsr 2018, item code: 7.7.1, djb s.o.r. 15 rubber mats for electrical purpose as per is: 5424 – 1969, black, red, blue plain chequered of following thickness of: (1mx 2 m) 10 mm thickness. d.j.b. s.o.r. make jyoti, national and any approved make of djb 16 supply and fixing of m.s.bracket bend & clamp for install the led lights as required at site. 17 earthing with g.l. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required details of cost for one set dsr 2018 code 5.4, d.j.b. s.o.r. 18 providing• and fixing 25 mm x 5 mm• g.l. strip in 40 mm dia g.l. pipe from earth electrode including connection with g.l. nut, bolt, spring, washer excavation and refilling etc. as required. dsr 2018 code 5.11, d.j.b. s.o.r. 19 cotton waste, cleaning cloth etc. dsr 2018, code no. 2938 20 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.a. (6 to 32 amp) single pole dsr 2018, item code 2.10.1 & djb s.o.r. 21 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.b. (32 amp) triple pole dsr 2018, item code 2.10.4 & djb s.o.r. 22 replacement of motor connection plate with stud & nut bolt etc. as per sample. 23 testing & commissioning as follow: all functional tests, checking for all tightness of nuts and bolts, testing of the circuit at site on load with engineer in charge as per relevant is. ...

Indian Army - Delhi

32998244 bids are invited for title 1 provision of ac and stabilizer along with connected work in access control cell acc and internet server room at jcb building m house annexe under ge i r and d delhi title 2 supply and install hi wall slit units indoor or outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimun 3 star rating and eer 3.2 of capacity 2.0 title 3 supply and install cassette type units indoor or outdoor complete with cordless remote control unit twin rotary compressor single phase units 220v 240v 50 hz of capacity 3.0 tr title 4 supply and fix voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation 170v to 250v with accuracy 2.5% and of capacity 5 kva title 5 mand l for sheet metal enclosures with plug top and mcbs single pole and natural enclosures with two pin and earth plug and socket complete with one single pole mcb 32a capacity all as per directed title 6 mand l for sheet metal enclosures with plug top and mcbs single pole and natural enclosures with two pin and earth plug and socket complete with one double pole mcb 63 a capacity all as per directed title 7 mand l for submain wiring along with earth wire with the 2 x 4.0 sqmm 4.0sq mm earth wire of fr lsh pvc insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories complete all as required or all as specified and as directed by engr in charge title 8 mand l for submain wiring along with earth wire with the 2 x 10.0 sqmm 10.0 sq mm earth wire of fr lsh pvc insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories complete all as required or all as specified and as directed byengr in charge title 9 s and f in replacement of electrolyte garade copper tubing of size 3.8 suitable for any type split type ac including synthetic rbber foam complete all as specifed and directed. note the quoted rate is inclusive of necessary t&p rope ladder etc with safety equipment for execution the work upto six stories buiding. title 10 all as per item no 08 here in before but size 5.8 complete all as specified and directed...

Indian Army - Delhi

32914149 bids are invited for gas charging refrigerant r22, r410 for inverter type split, window ac upto 2.0 tr including servicng and overhauling any other minor repair. , s and f in replacement of interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber type tubular insulation and interconnecting copper conductor pvc insulated cable , m and l in replacement of 3 core cable size 4sqmm, 6sqmm as per site requirement, frls type for continuous earth wire and duly connected to common earth. , gas charging r 410 for cassette type ac 4.0 tr including servicng and any other minor repair. , gas charging r 410 for ductable ac 11 2x5.5 tr tr including servicng and any other minor repair. , supply and fixing in replacement of running capacitor 50 plus 6 mfd , servicing and overhauling of tower, cassette, ductable acs including filter cleaning and minor repair if it is required. , supply and fixing in replacement of pcb kit fornormal split type ac upto 2tr complete including condencercoil and other accessories , supply and fixing in replacementof pcb kit ductable ac 11 tr 2x5.5 complete includingcondencer coil and other accessories , supply and fixing inreplacement of pcb kit for cassette ac 4 tr completeincluding condencer coil and other accessories , supply andfixing in replacement of compressor for split type ac upto2tr , supply and fixing in replacement of compressor fortower type ac 4tr , supply and fixing in replacement ofcompressor for ductable ac 5.5 tr , supply and fixing inreplacement condensor motor for split ac upto 2 tr , supplyand fixing in replacement fan motor for split ac upto 2tr , supply and fixing in replacement of pvc drain pipecomplete with fittings size 25 mm diameter total quantity : 380...

Delhi Jal Board - Delhi

32728298 improvement of lighting system at bapu park kotla bps ( ac 42 ) . , s / o 20w led batten light. make: bajaj / havells / crompton / any djb approved make. , s / o 70w led street light. make: bajaj / havells / crompton / any djb approved make. , s / o 63 amp double pole mcb. make:havells / l&t / any djb approved make. , s / o 1200 mm size ceiling fan.make:havells / orient / crompton / any djb approved make. , s / o 300 mm size exhaust fan.make:havells / orient / crompton / any djb approved make. , s / o 450 mm size exhaust fan.make:havells / orient / crompton / any djb approved make. , s / o 6 meter street light gi pole of top dia 76 mm. make: bajaj / havells / djb approved make. , s / o junction box for gi pole. make: sintex / bajaj / djb approved make. , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 25 sq.mm 2 core armored cable. make: havells / polycab / any djb approved make. , erection of metallic pole of following length in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refilling etc. as required. above 4.5 metre and upto 6.5 meter. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.15 / 16 a switch. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.6 pin 15 / 16 a socket outlet. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , laying and fixing of one number pvc insulated and pvcsheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thick saddle ) , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer andfinish paint etc. as required. , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way, double door. , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole. , supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 a. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. upto 450 mm sweep. , earthing with g.i. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Delhi Jal Board - Delhi

32728241 renovation / improvement of internal lighting system at je civil store hauz khas ( ac 43 ) . , s / o 20 w led batten light. make: bajaj / havells / crompton , s / o 45 w led street light. make: bajaj / havells / crompton , s / o 450 mm size exhaust fan. make: havells / orient / crompton , s / o 1200 mm size ceiling fan. make havells / orient / crompton , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100 volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 25 sq.mm 3 core armored cable.make: havells / grandlay / gloster / any djb approved make. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenol laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, includes wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally used where 3 phase outlets are required. 8way, double door ( 4+24 ) , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12way, double door . , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole. , supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. 63 ampdouble pole. , supplying and fixing following rating, four pole, ( three phase and neutral ) , 415 volts, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. , earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Public Works Department - Delhi

32714111 maintenance of electronic installation and fans at various aamc under nwed sub division ii, pitampura police line, delhi. ( sh providing / replacement of defective equipments at various aamc ) rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required.a ) group c 2 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.a ) 3 x 1.5 sq. mm 3 b ) 3 x 4 sq. mm 4 c ) 3 x 6 sq. mm 5 s / i / t / cof 1200 mm sweep bee star rating energy efficient isi marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase ac supply with power consumption of max.50w capable to deliver220 cfm ( min. ) , speed of 350 rpm ( min. ) i / c wiring the down rod of standard length ( upto 30 cm ) with 1.5 sqmm fr pvc insulated copper conductor single core cable etc as reqd. 6 sitc of surface / recess mounted 12 watt to 15 watt led downlighter luminaire made out of extruded aluminium / crc sheet body with minimum lumens output not less than 100 lumens per watt suitable for cool day white light having minimum cct 5700k to 6500k, power factor not less than >0.90, cri not less than70%, complete with all accessories etc. including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable & earthing including dismantling of existing old fittings if any complete etc as required. 7 supplying, installation, testing & commissioning of invertor technology refrigerator with minimum 260 litre capacity frost free double door , 3 star or better bee star rating refrigerator with 10 year compressor warranty suitable for operation on 215 b volt 50 hz ac supply complete , etc. as reqd. 8 supplying, installation, testing & commissioning of 900 va sine wave inverter ( ups type ) with 12 v , 150 ah 2 nos. smf tubular batteries with 2 year warranty i / c suitable trolley for battery housing complete with making connection etc as reqd. at site. 9 supplying, installation, testing & commissioning of 32” led, smart full hd tv having resolution minimum ( 1920 x 1080 ) including company supplied bracket on wall complete etc as reqd. 10 supplying, installation, testing & commissioning of water dispenser with minimum 3 ltr. water storage capacity suitable for operation 230 240 volt 50 hz ac supply having water heating and cooling capacity of minimum 2.5 litre / hour with cold storage compartment , auto shut off and capable of dispensing hot, normal and cold water etc. as required. 11 sitc of 1.5 tr window type air conditioner unit fitted with copper condensor coil, rotary compressor duly filled with eco friendly refeigerant gas ( r 32 or better ) having bee star rating : 5 star ( bee star rating year 2021 ) , with cooling capacity not less than 5100 watt, input power consumption not more than 1575 watt with cordless remote suitable for operation on 230 volts, single phase ac supply in the exisiting window including dismantling of existing air conditioner & fixing ac with suitable size 3 inch thick wooden frame as per size of the ac, smooth fine & paint with two or more coats of super enamel paint matching of room interior & remaining space will covered with suitable thick wooden ply and sealing the fap etc. complete as required. at site. 12 sitc of energy efficient hi wall split type ac unit of 1.5 tr capacity 5 star / ( invertor based technology ) bee rating , nominal cooling capacity of minimum 5100 watt, suitable for operation on single phase, 220v, 50 hz, ac supply i / c electronic remote control, comprising of both indoor and outdoor unit with copper condensor coil, eco friendly gas, ms angle iron stand for outdoor unit including 6 meter length, 4 core 2.5 sq.mm.wire, 4 mtr. copper tube of suitable size, wall thickness 0.8mm duly insulated with 9mm nitrile insulation, 5 mtr. pvc drain pipe of size 25mm i / c elbow, tee, socket, cement solvent etc. complete as reqd. 13 supplying & fixing of 4 kva capacity automatic voltage stablizer with time delay relay and high / low voltage trip facility having voltage range 150 v to 290 v +10% with copper flexible cable connection etc. as required at site. 14 supplying, installation, testing and commissioning of prewired, 20 to 22 watt aluminium body , heat sink driver 1200 mm long led batten fitting wall mounted luminaire having the following specifications :i ) total system power 2000 lumensii ) colortemprature 5700 k to 6500 kiii ) power factor not less than 0.95iv ) cri not less than 80, v ) system lumen efficency not less than 100 lm / w, complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as reqd....

Delhi Jal Board - Delhi

32677663 wiring / electrification of newly constructed residential complex of ceo djb at kilokri site at jal vihar ( ac 41 ) . , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. legrand / north west , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required . 2 x 4 sq. mm + 1 x 4 sq. mm earth wire make grandlay / havells / polycab , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection etc. as required. , laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.upto 35 sq.mm , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required , supplying and fixing following way prewired sp&n mcb distribution board of steel sheet for 240 volts on surface / recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size frls pvc insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) .12 way, double door legrand / l& t / havells , supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole legrand / l& t / havells , supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 amps legrand / l& t / havells , supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. legrand / l& t / havells , supplying and making end tramination with brass compression gland and aluminium lugs for following sizes of pvc sheathed xlpe aluminium conductor cable of 1.1 kv grade as required. 3 x 10 sq.mm , 3.5 x 70 sq.mm , 4 x 50 sq.mm , fabricating, sitc of cubical panel made out of 2 mm thick m.s sheet & 300 mm deep, 2sq.mtr. compartmentalized for accomodation of electrical accossories with 400 amp.4 nos.al. bus bars i / c angle iron frame grouting with cc foundation i / c two cotes of sinthetic enamle paint complete etc. as reqd. cpri approved supplying, installation, testing and commissioning of following electrical associries in the existing cubical panel etx.as req.with following items. 250 amp. 25 ka fpmccb with spreader & n / l 2nos make schinder / l&t / abb 160 amp. 25 ka fpmccb with spreader & n / l 5nos make schinder / ge / l&t / abb 0 500 amp volt meter ( digital ) with selector switch 1no make ae / l&t 0 500amp. meter ( digital ) with selector switch& suitable size ct, s 1no make ae / l&t 63 amp dp mcb 6 nos make havells / l&t / abb , supply & fixing3 feet long fan down road wirh dashwashner in the existing fallcelling, i / c wiringand all other arrangment as per site requrment. , supply & fixingflexi neon led stip 3500ka / 6500ka wirh wiring and all other arrangment as per site requrment. philips / havells , supply & fixingvenus conical fitting wirh 23 watt led lamp at the height of 7 8 mtri / c wiring and all other arrangment as per site requrment. make decon , supply & fixing surface mountingtwinlight fitting 10 15 watt ledout door up & down light withip 65 protection with 3000k / 5700k fixing at the height of 3 4 mtri / c wiring and all other arrangment as per site requrment. make philips / havells / crompton...

Delhi Jal Board - Delhi

32460037 bids are invited for providing of 72 watt led street light , providing of 24 watt led street light , providing of pole box suitable mounted on pole wall , wiring for circuit or submain wiring along with earth wire , providing of 100 amp mccb tp 35 ka with sheetsteel encloser box , fixing of led fittings and mccbs andpole boxes , testing and commissioningimprovement of electrification and other allied works at total quantity : 938...

Delhi Jal Board - Delhi

32165764 providing and fixing of fixtures and other allied accessories in residential cum office complex of ceo djb at kilokari site, jal vihar. , wiring for light point / fan point / exhaust fan point / call bell point, with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required group c. make grandlay / havells / polycab , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offrlspvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. make grandlay / havells / polycab 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offrlspvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. make grandlay / havells / polycab 2 x 6 sq. mm + 1 x 6 sq. mm earth wire , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offrlspvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. make grandlay / havells / polycab 4 x 16 sq. mm + 2 x 6 sq. mm earth wire , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection etc. as required. , supplying and drawing of utp 4 pair cat 6 lan cable in existing surface / recessed steel / pvc conduit as required 1 run of cable make d link / havells , laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. upto 35 sq.mm , laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required above 35 sq. mm and upto 95 sq. mm , installation, testing and commissioning of pre wired, fluorescentfitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , earthing with copper earth plate 600mmx600mmx3mm thick including accessories, and providing masonryenclosure with cover plate heaving locking arrangement and watering pipe of 2.7 meter long etc. without charcoal / coke / and salt as reqd , p / f 25mmx5mm copper strip in 40 mm dia gi pipe from earth electrode including connection with gi pipe from earth electrode including connection with gi nut , bolts, spring, washer excavation and re filling etc as rqrd. , supplying and laying 25 mm x 5 mm copper strip at 0.50 metre below ground as strip earth electrode i / c connection / termination with gi nut bolt , springwatsher etc , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required , installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. , s / fixing 100mm x 50mm dlp trunking with cover on the existing wall / panel i / c testing commissioning etc as reqd. make; mk / legrand , s / fixing 32mm x 16mm dlp trunking with cover on the existing wall / panel i / c testing commissioning etc as reqd. make; mk / legrand , supplying & fixing 100 amp 25 ka tp mccb with sheet steel encloser box inculding all necessary modification incoming & outgoing connections with all safety arrangement testing commissioning etc. as req. make: l&t , supplyingof following sizepvc insulated pvc sheathed aluminium / copper conductor armouredcable as required. 3 x 6sq mm copper cable. make: grandlay / havells / polycab , supplyingof following sizepvc insulated pvc sheathed aluminium / copper conductor armouredcable as required. 4 x 50 sq mm al. cable. make:grandlay / havells / polycab , supplyof ceiling fan 1200 mm sweep brushed nickle / antique brass / antique copper including wiring the down rods of standard length ( upto 30cm ) with 1.5sq.mm frls pvc insulated, copper conductor single core cable including providing and fixing finolex laminated seat cover on the fan box etc. as required. make havells / crompton , supply, of ceiling fan 600mm sweep, white including wiring the down rods of standard length ( upto 30cm ) with 1.5sq.mm frls pvc insulated, copper conductor rods of standard length ( upto 30cm ) with 1.5sq.mm frls pvc insulated, copper conductorsingle core cable including providing and fixing finolex laminated seat cover on the fan box etc. as required.make havells / crompton , supplyof ceiling fan 1400 mm sweep brushed nickle / antique brass / antique copper including wiring the down rods of standard length ( upto 30cm ) with 1.5sq.mm frls pvc insulated, copper conductor single core cable including providing and fixing finolex laminated seat cover on the fan box etc. as required.make havells / crompton , supply of recess mountingdownlighter in celling 12 / 10 watt led 6500klamp with crisp light throw and high cri. complete with all acessoriesetc. as required.philips / havells , supplysurface mounting celling fitting 22 / 24 watt led 6500klamp with crisp light throw and high cri. complete with all accessoriesrequired.philips / havells , supply of surface mounting celling fitting 7 / 6watt led 6500k lamp with crisp light throw and high cri. complete all accessories etc. as required.philips / havells , supply of2500rpm vento jet10 off white domestic exhaust fan, fhvvjstowh04, sweep: 100 / 150 mm . complete all accessories etc. as required.philips / havells , s / o 1 x20 watt led fitting with 1 no20 watt led tube, box type { make phillips / havells } , providing & fixing of pressure boosting pump 0.6 hp single phase, with pressure range of 1.4 2.4 kg / cm2 for 5 nos. outlet taps, 2 stage. make: kirloskar / crompton / djb approved make. , providing & fixing of geyser, 25 ltr capacity, model adonia r make: havells , providing & fixing of geyser, 10 ltr capacity, model adonia r make: havells...

Delhi Jal Board - Delhi

32165750 improvement of lighting system at moolchand online bps and moolchand shopping complex bps. , s / o 20w led batten light. make: bajaj / havells / crompton / any djb approved make. , s / o 45w led street light. make: bajaj / havells / crompton / any djb approved make. , s / o 70w led street light. make: bajaj / havells / crompton / any djb approved make. , s / o 450 mm size exhaust fan.make:havells / orient / crompton / any djb approved make. , s / o 600 mm size air circulator fan.make:havells / orient / crompton / any djb approved make. , s / o 1200 mm size ceiling fan.make:havells / orient / crompton / any djb approved make. , s / o 63 amp 4 pole mcb. make:havells / l&t / any djb approved make. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable insurface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable forloop earthing as required. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.15 / 16 a switch. , supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required.6 pin 15 / 16 a socket outlet. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 4 way ( 4+12 ) , double door. , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole. , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer andfinish paint etc. as required....

Indian Army - Delhi

32151027 bids are invited for installation of split ac i lancer wrac lg wrac any make complete including powder coated ms sheet metal stands chowky wall mounting for mounting outdoor condensing unit all as specified and directed. , gas charging for lg wrac split ac lancer wrac left right including servicing and any other minor repair complete all as specified and directed. , supply and fixing of interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber type as per size 5 by 8 inch and 3 by 8 inch , m and l for 3 core cable size 4 sqmm 6 sqmm as per site requirement frls type for continious earth wire and duly connected to common earth dolly complete all as specified and directed , supply and fixing running capacitor 50 plus 6 all as specified and directed. , servicing and overhauling ofany type of split ac lg wrac including filter cleaning andminor repair if it is required all as specified and dirrected. ,supply and fixing pcb kit for normal split type ac upto 2trcomplete including condenser coil and other accessories allas specified and directed. , supply and fixing compressor forsplit type ac upto 2tr any make all as specified anddirected. , supply and fixing condenser motor for split acupto 2 tr all as specified and directed. , supply and fixingfan motor for split ac upto 2tr. , supply and fixing 1 by 2inch and 14 inch valve set. , supply and fixing of pvc drainpipe complete with fittings, supports as per specificationsize 25mm diameter.years of past experience required for2 year (s)same/similar service total quantity : 686...

Delhi Jal Board - Delhi

31894030 renovation / improvement of internal lighting system at botteling plant greater kailash i, , s / o 20 w led batten light. make: bajaj / havells / crompton , s / o 25 w led street light. make: bajaj / havells / crompton , s / o 450 mm size exhaust fan. make: havells / orient / crompton , s / o 1200 mm size ceiling fan. make havells / orient / crompton , s / o led fitting and frame 600mm x 600 mm ( n.s ) with het diffuser, recess mounting 36 watt.make philips / havells / bajaj / crompton , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 25 sq.mm 4 core armored cable. make: havells / grandlay / gloster / any djb approved make. , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 10 sq.mm 2 core armored cable. make: havells / grandley / gloster / any djb approved make. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenol laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, includes wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. , supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required ( note : vertical type mcb tpdb is normally used where 3 phase outlets are required. ) 8way, double door ( 4+24 ) , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12way, double door , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole , supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. 63 ampdouble pole , supplying and fixing following rating, four pole, ( three phase and neutral ) , 415 volts, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 4 x 4 sq. mm + 2 x 4 sq. mm earth wire , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.4 x 2.5sq. mm + 2x 2.5 sq. mm earth wire , earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Public Works Department - Delhi

31726890 maintenance of street lights, high masts on delhi pwd roads under pwd m south division during 2021 22 (sh providing maintenance staff and material for services of ei works at various pwd offices under south electrical division.) maintenance of street lights, high masts on delhi pwd roads under pwd m south division during 2021 22 (sh providing maintenance staff and material for services of ei works at various pwd offices under south electrical division.) , maintenance of electrical internal & external installation, electrical main panels, distribution boards, compound / street / security lighting on all days except sundays & holidays & attending day to day complaints, rectification of faults, up keeping and preventive maintenance of electrical installation complete as required at various pwd offices under south electrical division. staff: 1.wireman cum operator 2 nos. in general shift 2.khallasi 2 nos. in general shift , supply of the following material for the maintenance of internal and external electrical installations to be installed by the staff to be deputed as above. , 6 32 amp rating sp mcb c curve, 10 ka , 6 32 amp rating, spn mcb c curve, 10 ka , tp mccb 100 a 16 ka , 1.5 sqmm cu conductor frls pvc insulated wires , 4.0 sqmm cu. conductor frls pvc insulated wires , 5/6 amp switch (modular type) one way , 15/16 a switch (modular type)one way , 3 pin 5/6 a socket (modular type) , 6 pin 15/16 a socket (modular type) , stepped type module fan regulator (2 module) , rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. , group c , wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required , group c , wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. , 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire , 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , 4 x 4 sq. mm + 2 x 4 sq. mm earth wire...

Municipal Corporation - Delhi

31630326 procurement of material for day to day maintenance, repair, rewiring and improvement of ei and fans at house tax building, sector 09 r. k. puram in ward no. 65s under south zone part a wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable etc. as required.group c 2 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required. group c 3 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 3 x 2.5 sq. mm 4 6 x 2.5 sq. mm 5 3 x 4 sq. mm 6 6 x 4 sq. mm 7 3 x 6 sq. mm 8 6 x 6 sqmm 9 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 10 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 11 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 12 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 13 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 14 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 15 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 16 4 x 6 sq. mm + 2 x 6 sq. mm earth wire 17 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 18 wiring for light / power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 19 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cmm / w ) minimum 6.85, air delivery minimum 215 cmm, 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 20 supply of 12 ( 300 mm ) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required. 21 installation of exhaust fan in the existing opening , including making good the damage, connection, testing , commissioning etc.as requiredup to 450 mm sweep 22 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole ( a ) single pole 23 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. ( a ) 63 a 24 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. ( a ) 63a 25 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 a, 16 ka, tpmccb 26 sitc led tube type luminaire 20 watt rating complete with polycarbonate housing batten integrated integrated electronic driver prewired with high efficient leds with the following. a ) total system wattage 20 watt + / 5 % b ) luminous efficacy lumens / watt = 95 c ) power factor = .95 27 supply of xlpe insulated and pvc sheathed al conductor armoured cable confirming to is: 7098 part 1 / 1988 as required. 4x10 sqmm 28 supply of xlpe insulated and pvc sheathed al conductor armoured cable confirming to is: 7098 part 1 / 1988 as required. 4x16 sqmm 29 supply of xlpe insulated and pvc sheathed al conductor armoured cable confirming to is: 7098 part 1 / 1988 as required. 2x6 sqmm 30 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required upto 35 sq. mm 31 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal pipe as required.upto 35 sq. mm 32 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm ( clamped with 1mm thick saddle ) 33 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a, “c” curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 34 supplying and fixing brass batten / angle holder including connections etc as reqd 35 supply of 9 watt led retrofit lamp suitable for b 22 holder 36 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way, double door 37 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way, double door 38 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required 39 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 a & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 40 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modular switch, connections etc. as required 41 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. ( a ) 5 / 6 a switch 42 ( b ) 15 / 16 a switch 43 ( c ) 3 pin 5 / 6 a socket outlet 44 ( d ) 6 pin 15 / 16 a socket outlet 45 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 46 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required ( a ) 4 module ( 125 mmx75 mm ) 47 8 module ( 125 mmx125 mm ) 48 12 module ( 200 mmx150 mm ) 49 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 50 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 51 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. 52 supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nutbolt & spring washer spaced at 50mm ) 53 supply, installation, testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated , specially designed al bus bar 400 a to 630 a with heatshrinkable colour coded sleeves suitable for accomodating mccbs / mcbs / isolators ) complete with digital meter module, including voltmeter, ammeter with selector switch , cts control fuse and indicating lights including connections etc . as required ( confirms to is: 8623 ) 54 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 55 25mm 56 32mm 57 40mm 58 s / i / t / c of surface mounted crca housing 36 w led luminaire with acrylic cover diffuser with following specifications including fixing in existing wall / surface with connections as required ( a ) total system wattage = 36 watt+ / 5% ( b ) luminous efficacy > 95 lumens / watt ( c ) power factor.=0.95 59 sitc of wall mounted fan 400 mm sweep rated voltage 220 230 ac rated frequency 50 hz speed 1280 1350 rpm with desire colour 60 supplying, lowering and fixing of gi pipe medium ( m class ) i / c cutting threading on both sides etc. isi marked etc as required 50 mm dia ( nominal bore ) 61 s&f following size of g.i.socket as required.50mm 62 s&f following size of g.i.union as required.50mm 63 s&f following size of g.i.elbow as required.50mm 64 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) :50 mm dia 65 p&f following sizes of pvc insulated & pvc sheathed copper conductor 3 core submersible cable conforming to is 694 / 1990 etc as required.3x10 sqmm 66 supply, installation, testing and commissioning of cubical type control panel board for single phase & three phase submersible pumping set of following rating complete with contactor, relay, mcb, condenser, voltmeter, ammeter and indication lamp etc including connctions etc as required.10 hp ( three phase ) 67 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 68 part b supply of 1.5.sq .mm isi mark , frls pvc insulated, single core copper conductor cable. 69 supply of 2.5.sq .mm isi mark , frls pvc insulated, single core copper conductor cable. 70 supply of 4.0 sq .mm isi mark , frls pvc insulated, single core copper conductor cable. 71 supply of 6.0 sq .mm isi mark , frls pvc insulated, single core copper conductor cable. 72 supplying of 6 a to 32 a ratings, sp mcb, “c” curve, 10 ka breaking capacity. 73 supply of 20 mm dia. isi marked , pvc conduit 74 supply of s.p. 5 / 6 amps, one way switch, piano type isi marked 75 supply of s.p. 15 / 16 a, one way switch, piano type isi marked 76 supply of 3 pin 5 / 6 amps socket outlet, piano type isi marked 77 supply of 6 pin 15 / 16 & 5 / 6 amps socket outlet, piano type isi marked 78 supply of s.p. 5 / 6 a, one way modular switch, isi marked 79 supply of s.p. 5 / 6 a, two way modular switch, isi marked 80 supply of s.p. 15 / 16 a, one way modular switch, isi marked 81 supply of 3 pin 5 / 6 a modular socket outlet, isi marked 82 supply of 40 a, 2 pole isolator. 83 supply of 63 a, 2 pole isolator. 84 supply of 63 a, 4 pole isolator. 85 supply of sheet steel dp mcb enclosure 86 supply of 6way, spn, double door, mcb db 87 supply of 8 way, spn, double door, mcb db 88 supply of 12 way, spn, double door, mcb db 89 supply of led tubelight lamp t 5 / t 8 20 watt rating made up ofhigh efficient ledswith the following specifications: ( a ) total system wattage 20 watt + / 5% ( b ) luminous efficacy lumens / watt >=95 ( c ) power factor >=0.95 90 supply of universal aluminium batten 4ft long pre coated crca sheet steel, end caps suitable for t5 and t8 led tubelights etc as required. 91 supply of pvc batten / angle holder 92 supply of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cmm / w ) minimum 6.85, air delivery minimum 215 cmm, 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 93 supply of al. alloy / cadmium plated iron screws, 20 mm 94 supply of gi saddles 25mm x 0.90mm for conduit above 25mm 95 supply of pvc clip for fixing cable 96 synthetic enamel paint in all shades except black or chocolate shade 97 supply of soft brush 98 supply of red oxide zinc chromate primer 99 supply of wire brush 100 supply of hessian cloth 101 supply of 20 mm pvc bends 102 supply of 20 mm pvc junction box, one way 103 supply of 20 mm pvc junction box, two way 104 supply of 20 mm pvc couplers...

Delhi Jal Board - Delhi

31597049 wiring / electrification of newly constructed residential building of ceo ( djb ) at kilokari, jal vihar site. , wiring for light point / fan point / exhaust fan point / call bell point, with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. group – c , wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 4 x 4 sq. mm + 2 x 4 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 4 x 10 sq. mm + 2 x 6 sq. mm earth wire. , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection etc. as required. dsr 1.32 , supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, c curve including connections, painting etc. as required. , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. telephone socket outlet. , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. tv antenna socket outlet. , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.rj 45 socket outlet , supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , supplying and drawing following pair 0.5 mm dia frls pv insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 4 pair b. , supplying and drawing of utp 4 pair cat 6 lan cable in existing surface / recessed steel / pvc conduit as required run of cable , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , supplying and fixing following way prewired tp&n mcb distribution board of steel sheet for 440 volts on surface / recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size frls pvc insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) .12 way, double door. , supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole. , supplying and fixing following rating, four pole, 440 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 100 amps....

Delhi Jal Board - Delhi

31597016 improvement and electrification work at office building of ee ( ld and i ) . , s / o 20w led batten light. make: bajaj / havells / crompton , s / o 70w led street light. make: bajaj / havells / crompton , s / o 300 mm size exhaust fan. make :havells / orient / crompton , s / o 1200 mm size ceiling fan.make: havells / orient / crompton , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 10 sq.mm 2 core armored cable. make: havells / polycab / any djb approved make. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , wiring for circuit / sub main wiring along with earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed medium class pvc conduit asrequired. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , supplying and fixing suitable size gi box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modularswitch, connections etc. as required. , supplying and fixing suitable size gi box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modularswitch, connections etc. as required. , supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box / wooden block including connections etc. as required. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of2cx 10 sq. mm size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thich saddle ) . , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including gearthing etc. as required. ( but without mcb / rccb / isolator ) 12 way, double door , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole , supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 a , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. , earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc .with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Delhi Jal Board - Delhi

31524555 wiring / electrification of newly constructed residential building of ceo ( djb ) at kilokari, jal vihar site. , wiring for light point / fan point / exhaust fan point / call bell point, with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. group – c , wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 4 x 4 sq. mm + 2 x 4 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire. , wiring forcircuit / submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 4 x 10 sq. mm + 2 x 6 sq. mm earth wire. , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection etc. as required. dsr 1.32 , supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, c curve including connections, painting etc. as required. , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. telephone socket outlet. , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. tv antenna socket outlet. , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.rj 45 socket outlet , supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , supplying and drawing following pair 0.5 mm dia frls pv insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 4 pair b. , supplying and drawing of utp 4 pair cat 6 lan cable in existing surface / recessed steel / pvc conduit as required run of cable , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , supplying and fixing following way prewired tp&n mcb distribution board of steel sheet for 440 volts on surface / recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size frls pvc insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) .12 way, double door. , supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole. , supplying and fixing following rating, four pole, 440 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 100 amps....

Delhi Jal Board - Delhi

31493884 nit no. 25 / ee ( em ) m 10 / ( 21 22 ) item no 1 improvement and electrification work at office building of ee ( ld and i ) . , s / o 20w led batten light. make: bajaj / havells / crompton , s / o 70w led street light. make: bajaj / havells / crompton , s / o 300 mm size exhaust fan. make :havells / orient / crompton , s / o 1200 mm size ceiling fan.make: havells / orient / crompton , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 10 sq.mm 2 core armored cable. make: havells / polycab / any djb approved make. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , wiring for circuit / sub main wiring along with earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed medium class pvc conduit asrequired. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , supplying and fixing suitable size gi box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modularswitch, connections etc. as required. , supplying and fixing suitable size gi box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modularswitch, connections etc. as required. , supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box / wooden block including connections etc. as required. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of2cx 10 sq. mm size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thich saddle ) . , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including gearthing etc. as required. ( but without mcb / rccb / isolator ) 12 way, double door , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole , supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 a , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. , earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc .with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Delhi Jal Board - Delhi

31414264 nit no. 24/ee(em)m 10/(21 22)item no 1 wiring / electrification of newly constructed residential building of ceo(djb) at kilokari, jal vihar site. , wiring for light point / fan point / exhaust fan point / call bell point, with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. group – c , wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , wiring forcircuit /submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. , wiring forcircuit /submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. , wiring forcircuit /submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 4 x 4 sq. mm + 2 x 4 sq. mm earth wire. , wiring forcircuit /submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire. , wiring forcircuit /submain wrining alongwith earth wire with the following sizes offr pvc insulated copper conductor. single core cable in surface / recessed pvc conduit as required. 4 x 10 sq. mm + 2 x 6 sq. mm earth wire. , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. dsr 1.32 , supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, c curve including connections, painting etc. as required. , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. telephone socket outlet. , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. tv antenna socket outlet. , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.rj 45 socket outlet , supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. , supplying and drawing following pair 0.5 mm dia frls pv insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 4 pair b. , supplying and drawing of utp 4 pair cat 6 lan cable in existing surface/ recessed steel/ pvc conduit as required run of cable , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , supplying and fixing following way prewired tp&n mcb distribution board of steel sheet for 440 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size frls pvc insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (but without mcb/ rccb/ isolator).12 way, double door. , supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole. , supplying and fixing following rating, four pole, 440 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 100 amps....

Indian Army - Delhi

31311921 bids are invited for boq_1 ml for point wiring with colour coding multistandard copper conductor cable pvc insulated frls and unsheathed size 1 point 5 sqmm with pvc casing cappingwith fixing accessories to be fixed for one light fan or bell point cotrolled by one switch with pressedsteel concealed termional boxes covered with 3 mm thick laminated sheet with all fittings incl eath wire of pvc insulated copper conductor cable of size 1 point 5 sqmm for earth wire connected to common earth dolly all as specified and directed , boq_2 sand f switch piano flush type bell push 5 amps single pole one way , boq_3 s and f ceiling reose surface bakwlite 65 x 50 mm 2 to 3 terminal all specified , boq_4 s and f wall mounted fan plastic body of size 400 mm sweep 1300 rpm 3 blade complete all as specified and directed by engr in charge make havells or bajaj or usha or crompton or orient or equivalent , boq_5 supply and fix led pillar lights outer body water proof complete all as specified and directed by engr in charge , boq_6 supply and fixing round shape 6 watt 220 volts ac recessed type with high efficiency pmma diffuser soft glare free light complete with driversled lamp suitable for roof ceiling including connecting up with three core flexible copperconductor cable of suitable size complete , boq_7 supply and fix water heater storage type electric capacity 25 litres bee 5 star rated with all accessories all as specified and directed , boq_8 suply and fix energy efficient led flood light new generation energy saving led flood light powder coated pdc aluminiuym body toughened glass visor long life save exclusive cast aluminium flood light fitting with high power leds 50 watt as light source including necessary fixing arrangements all as specifed and as direced of make polycab cat part no pccgfi1 50 60 or equivalent of wipro philips or havells , boq_9 s and fix electronic metre temper proof lcd display with polycarbonate cover complete all as specifed and direcrted total quantity : 123...

Northern Railway - Delhi

30865713 auction sale of galvanized steel for trd/ohe scrap as: (1) rsj cut pieces 8x6. qty. 6 nos.=1.172 mt, (2) ttu cut pieces. qty. nos.=1.239 mt, (3) nu cut pieces. qty. 25 nos.=6.994 mt, (4) ou cut pieces. qty. 12 nos.=5.330 mt, (5) ob cut pieces. qty. 1 no.=0.260 mt, (6) k 175 cut pieces. qty. 1 no.=0.319 mt, (7) b 200 cut pieces. qty. 1 no.=0.349 mt, (8) bfb 6x6 (bend). qty. 1 no.=0.352 mt, (9) ne 2 (bend). qty. 1 no.=0.199 mt, (10) be 2 (bend). qty. 1 no.=0.301 mt, (11) oe 1 (bend). qty. 1 no.=0.551 mt, (12) n 8. qty. 1 no.=0.302 mt, (13) n 8. qty. 2 nos.=0.505 mt, (14) be. qty. 8 nos.=2.143 mt, (15) ttb (bend). qty. 1 no.=0.383 mt, (16) anti creep and earth wire. qty.=0.800 mt, (17) super mast, x arm and cut fencing upright. qty.=0.300 mt, (18) febricated da 1. qty. 27 nos.=1.808 mt, (19) gi tube off size off lenth. qty. 900 nos.=4.500 mt, (20) nut and bolt off size. qty. 50000 nos.=2.500 mt, (21) febricated da 2. qty. 30 nos.=2.226 mt. total qty. 32.24 mt (appx)....

Indian Army - Delhi

30714579 bids are invited for boq_1 , boq_2 , boq_3 , boq_4 , boq_5 , boq_6 , boq_7 , boq_8 , boq_9 , boq_10 , boq_11 , boq_12 , boq_13 , boq_14 , boq_15 , boq_16 , boq_17 , boq_18 , boq_19 , boq_20 , boq_21 , boq_22 , boq_23 , boq_24 , boq_25 , boq_26 , boq_27 , boq_28 , boq_29 , boq_30 , boq_31 , boq_32 , boq_33 , boq_34 , boq_35 , boq_36boq title boq 01 total quantity : 1283 taking down carefully aluminium point wiring ( light, socket or power ) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc to be measured separetly including making good the disturbed portion / surface and deposit to mes store yard all as specified & directed by engineer in charge m&l for point wiring with colour coding multistranded copper conductor cable, pvc insulated ( frls ) and unsheathed size 1.5 sqmm with pvc concealed conduit / wall surface ( dia not les than 25 mm ) with fixing accessories for one light / fan / bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet incl. contineous earth wire of pvc insulated unsheathed multi stranded copper conductor cable size 1.5 sqmm for earth wire connected to common earth dolly all as specified and directed. all as per item no 2 above but for one 3 / 5 pin socket 5 amp on same board, with 1.5sqmm wire with 1.5sqmm earth wire. all as per item no 2 above but for one 3 / 5 pin socket 5 amp on independent board with 1.5sqmmwire with 1.5sqmm earth wire . all as per item no 2 above but for 3 pins socket outlet 15 amps independent with 4 sq mm incl contineous earthing with multistandred copper conductor pvc insulated unsheathed size 2.5 sq mm complete all as specified and directed. s&f modular switch flush type, 5 / 6 amps, single pole one module white colour complete all as specified 230 volts , ac complete. s&f modular switch flush type, 15 / 16 amps, single pole one module white colour complete aa as specified , 230 volts , ac complete. s&f modular socket 3 pins combined, 5 / 6 amp, flush type ( multi purpose ) two module , 230 volts , ac complete . s&f modular socket 5 / 6 pins combined, 6a / 16 amp, flush type ( multi purpose ) two module 230 volts , ac complete. s&f modular white cover plate with frame suitable for three module way 230 volts , ac complete. s&f modular white cover plate with frame suitable for four module way s&f modular white cover plate with frame suitable for six module way s&f switch piano flush type / bell push, 5 amps, single pole one way 230 volts , ac complete s&f socket 3 / 5 pins, 6 amp, flush type piano ( multi purpose ) 230 volts , ac complete s&f socket 15 amps flush type, 3 / 6 pin, 230 volts , ac complete. s&f switch 15 amps flush type 230 volts , ac complete. s&f ding dong door bell 230 volts , ac complete. s&f ceiling rose, pvc / polycarbonate isolated body , surface backlite, 65x50mm, three terminals, 230 volts , ac complete. s&f modular stepped type electronic fan regulator flush type, 120 w, two module 230 volts , ac complete all as specified and directed by engineer in charge. s&f batten holder pvc / polycarbonate base / back suitable for led lamp. 230 volts , ac complete. s&f led bulbs 9 / 10w b 22 pin type 230 volts , ac completeall as specified and directed by engineer in charge. s&f single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 amps mcb complete including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f skylite recess mounting, 36w, led 2x2 luminaire integrated electronic driver, optics diffused, complete including electrical connection with copper cable from ceiling rose to fittings and including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f led tube light fittings 20w ( 4 feet ) wall mounted led batten extruded pvc heat sink provided for efficient heat dissipation & integrated electronic driver optics diffused complete including electrical connection with copper cable from ceiling rose to fittings and including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f led 6000k 10w decorative led lighting fixture with extruded pvc heat sink, environmental friendly complete and including taking down and deposit to mes store yard all as specified s&f led bulkhead luminaire 10w decorative type as per sample complete including electrical connection with copper cable from ceiling rose to fittings and including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f led building secuity light 25 watt made up of pressure die cast aluminium housing with mid power led as lightening source and pc cover having top opening inbuilt led driver with ip66 protection and impact resistance of ik 07 complete including gi bracket with nut bolts, washers etc including electrical connection with copper cable from ceiling rose to fittings and including taking down and deposit to mes store yard all as specified & directed by engineer in charge m&l for submain wiring with 2x6.0 sqmm+1x4.0sqmm earth wire single core pvc insulated frls sheathed copper cable connecting to common earth dolly in and including heavy duty pvc concealed conduit and dismantling and taking down existing unserviceable wiring, all accessories complete and deposit to mes store yard all as specified & directed by engineer in charge s&f distribution board 04 way tp&n double door are fitted with bus bars, neutral links suitable for 415v, 50hz, blanking plates, suitable for tp / fp mcb complete including taking down and deposit to mes store yard all as specified & directed by engineer in charge s & f single pole and neutral sheet metal enclosures for distribution board ( dbs ) suitable for mcbs fitted with bus bar , neutral link , earth bar and din rail 240 v, 50 hz supply double door sp&n db system 12 ways complete including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f mcb tpn 63 to 100 amps amps 415v incl all termnials, fitting etc including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f rcbos for earth leakage, over load & short circuit protection 2 pole , 25 amp rating, 300 ma capacity suitable for 240 volts and including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f rcbos for earth leakage, over load & short circuit protection 04 pole , 25 amp rating, 300 ma capacity suitable for 240 volts and including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f mcb spn 06 to 40 amps 240v incl all termnials, fitting etc. including taking down and deposit to mes store yard all as specified & directed by engineer in charge s&f mcb sp 06 to 40 amps 240v incl all termnials, fitting etc including taking down and deposit to mes store yard all as specified & directed by engineer in charge m & l for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in gorund ( earth pit not less than 2.25 mtr normal ground level ) , and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 15 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover ci frame pcc 1:3:6 type c 2 all as shown in electrical plate no 3 of ssr part i of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion including taking down and deposit to mes store yard all as specified & directed by engineer in charge...

Delhi Jal Board - Delhi

30684620 supply installation testing commissioning of enm equipments and allied works at sec 23 pkt 10 bps dwarka. 1 a part: monobloc pump set 7.5 hp, 3 phase, 100x100mm, 2900 rpm approx, climpeller. suitable capacity 840 lpm, 24 mtr head. make: kbl / m&p / jyoti / lubi / djb approved make 2 vertical dewatering submersible pump 3 hp, 3 phase, del. size 50 mm, 2900 rpm approx. ci impeller, head 10 mtr. make: kbl / m&p / jyoti / lubi / djb approved make 3 self priming motor coupled monoblock pumpset 3 hp, 3 phase, ci impeller, 40x40 mm, 10 mtr. head approx, make : kbl / m&p / jyoti / lubi / djb approved make 4 fabrication of ms base frame for above 7.5hp mono block pump set made from ms channelwith cross support and also fixing with ms vertical support u channeland 6nos drilling for foundation bolt as per site requirement. 5 fabrication of ms base frame for 3 hp self priming motor coupled monoblock pumpset made from ms channelwith cross support and also fixing with ms vertical support u channeland 6nos drilling for foundation bolt or as per site requirement. 6 supply of 300 ltr water storage tank for vacuum pumpset. make: syntex / isi / djb approved make. 7 s / o ci / di flanged foot valves150 mm dia, pn 0.2 ( as per is: 4038 ) make: kbl / ivc / vag / dorot / djb approved make 8 s / o di d / f sluice valve100 mm dia with ss spindle, pn 6 10 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 9 s / o di d / f sluice valve 150 mm dia with ss spindle, 1.0 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 10 s / o di d / f non return valve 100 mm dia, pn 1.0, ( as per is: 5312 ) make: kbl / ivc / vag / dorot / djb approved make 11 s / o gun metal gate valve of 50 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make: sant / leader / djb approved make 12 s / o gun metal gate valve of 40 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 13 s / o gun metal gate valve of 25mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 14 s / o gun metal non return valve of 40 mm nominal bore ( screwed end ) make : sant / leader / djb approved make 15 s / o double flanged ms pipe of 200 mm dia conforming to is : 3589 make : jindal / tata / djb approved make 16 s / o double flanged ms pipe of 150 mm dia conforming to is : 3589 / 3259 make : jindal / tata / djb approved make 17 s / o double flanged ms pipe of 100 mm dia conforming to is : 3589 / 3259 make : jindal / tata / djb approved make 18 s / o 50mm dia g.i. pipes complete with g.i. fitting and clamps, confirming to is:3259 make : jindal / tata / djb approved make 19 s / o 40 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 20 s / o 25 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 21 s / o 40mm size bronze glass indicator. make : sant / leader / djb approved make 22 fabrication of various ms standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per site requirement. 23 s / o 200 mm dia flanged joints to double flanged ms pipes and specials 24 s / o 150 mm dia flanged joints to double flanged ms pipes and specials 25 s / o 100 mm dia flanged joints to double flanged ms pipes and specials 26 s / o 100 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 27 s / o 150 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 28 s / o nuts bolts and washers of required size. 29 s / o neoprene packing. 30 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 35 sq mm ( forincoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 31 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 25 sq mm ( forincoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 32 2.0 mm electrical rubber mat 1x2 mtr, voltage gradeup to 3.3 kv ac & 240 v dc. isi marked ( as per is: 15652 / 2006 ) make: djb approved make 33 pressure gauge ( bourdon type ) , dial size 100 mm, analog type, material ss, measuring range : 0 7 kg / cm2 or as per site requirement make: h guru / fiebig / djb approved make 34 float and board type water tank level indicator suitable for ugr of depth 4.5 mtr 35 supplying and installing ms perforated cable trays of size 150 mm width x 50 mm depth x 1.6 mm thickness painted with powder coatingwith perforation not more than 17.5%, in convenient sections, joined with connectors, supported by 25 mm x 25 mm x 3 mm iron angleincluding bolts & nuts, painting with primer and finish paint. dsr ( e&m ) 4.1.2 36 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade offollowing size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thick saddle ) 37 making of rcc foundation of the monoblock pump set by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation 38 making of rcc foundation of self priming motor coupled pumpset by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation. 39 installation and fixing of the above pumpsets on the base frame includingjointing the pumpsets with suction / delivery line with proper alignment. the job also include fixing of valves , laying of cable and making thimbling of cable on both ends by 50sq. mm 6 nos thimbles, making connection the pump sets from starter / panel etc i / c watch and ward, cartage , painting of the suction delivery lines, ci valves, specials, ms base frame with good quality enamel paint after two coats of red oxide primer, loading and unloading taking all safety precaution arrangement, all tools and tackles the work including testing and commissioning all e&m equipment i / c various pumpsets at no load and full load in the presence of engineer in charge 40 earthing with g.i. earth plate 600 mm x 600 mm x6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 41 supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm ) 42 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x 2.5 sq. mm + 1x 2.5 sq. mm earth wire 43 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x4 sq. mm + 1x 4 sg. mm earth wire 44 supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5 / 6 a & 15 / 16 a socket outlet and 15 / 16 a piano type switch, connections, painting etc. as required. 45 supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole dsr e&m 2018 2.10.1 46 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted mccb, mcb & dbs including earthing etc. as required. ( but without mcb / rccb / isolator ) 4 way ( 4 + 12 ) , double door dsr ( e&m ) 2018 2.4.1 47 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 48 dcp type fire extinguisher 6 kg capacity suitable to fight abc type & electrically started fire, iso certified 49 shock treatment chart multicolour with rollers, size 5ox70cm approx. 50 fire fighting chart multicolour with rollers, size 37 70x100 mm approx. 51 electrical insulated rubber hand gloves tested for 11 kv isi marked ( as per is: 4770 ) make: djb approved make 52 metal first aid box b type contains following items: ( bandage, cotton, medical tape, anteseptic, pain reliever, antibiotic ointment, cough syrup, etc. ) as per relevent is specifications 53 supplying of fire buckets of 20 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters fire in blackand gold. cost shall be inclusive of providing ms stand portable type duly painted over a coat of primer. ( one stand shall be suitable for hanging 4 buckets ) ( as per is:2546 ) 54 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 55 exhaust fan 18 heavy duty for industrial use make: bajaj / crompton / philips / havells / djb approved make 56 supply of ceiling fan, 5 star rating 1200 mm blade size with regulator make: havells / crompton / bajaj / orient or any other djb approved make. 57 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto30cm ) with 1.5 sq.mm frls pvc insulated, copper conductor, single core cable etc. as required. dsr 2018 1.44 58 indoor lighting, suspended luminaire pendant typeled, 36 40w, 4 ft. length, white make bajaj / crompton / philips / havells / djb approved make 59 external lighting, streetlight led 45 w with suitabie clamp and support as required at site, white make : bajaj / crompton / philips / havells / djb approved make 60 supplying and fixing of 32 mm dia x 2.00 metres long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 61 lt distribution panel 1 ) distribution panel sheet steel enclosure made out of 2mm crca sheet totally enclosed, size 1200 x 900 x 350 mm having canopy powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. the each part of the fabricated panel will be strictly subjected to seven tank treatment .the various components, assemblies and sub equipments of the panel will be as per standard given in relevant is. the bus bar of the panel will be shaped out of high conductivity, electrolytic aluminum conductor and shall be liberal sized. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a ferule crimped to the wire. – 1 no.2 ) mccb 415v, tp 3phase 50h2, 100amp 1 no. make l&t / siemens 3 ) mcb 415v, tp 3phase 50hz, 6 32 amp 2 nos. make l&t / siemens 4 ) mcb 415v, tp 3phase 50hz, 63 amp 2 nos. make l&t / siemens 5 ) mcb single pole 6 amp. 6 nos. 6 ) mpp type power capacitor 7kvar unit 440v 3phase. 2 nos. make epcos7 ) power contactor 220v 3phase 50amp. 6 nos. make l&t / siemens8 ) power contactor 220v 3phase 18amp. 2 nos. make l&t / siemens9 ) over load relay 4 10samp 2 nos. make l&t / siemens 10 ) over load relay 20 33amp 2 nos. make l&t / siemens 11 ) amp. meter digital type 5 nos. make : l&t / ae 12 ) volt meter0 500v digital type 1 no. make l&t / ae 13 ) indicating lights ryb & on 7 nos. make havells / l&t 14 ) push button on / off with elements 8 nos. make l&t / sg 15 ) current transformer100 / 5 3 nos. make ae / saviour 16 ) fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect. loading , unloading by crane or heavy labor and cartage up to site dismantling of old panel structure including removing of cable etc. from site , cleaning & dressing the surface for installation of the panel at site on base frame laying of cable , termination of cable both incoming &out going side 1 job 17 ) installation of the panel at site, termination of cable both incoming &out going side through cable gland & thimble 1 job 18 ) loading, unloading & labour charges & cartage up to site 1 job19 ) testing & commissioning of panel & allied accessories as per required parameters with relevant is.testing of the panel prior to switching on as follow: 1 job i ) continuity and earth testing ii ) meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth 62 b part: maintain water supply of sec 23 pkt 4 bpss. the work includes operation of pump sets as per prevalent schedule and as change time to time on daily basis as per direction of engineer in charge, lt panel and all other electrical and mechanical equipments to maintain the water supply in the command area. the work including minor maintenance of e&m equipments like tightening the glands, greasing, dust blowing & misc. electrical work like replacement of bulb, tubelight, thimbles, etc. ( material will be provided by the deptt. ) , cleaning & sweeping of pump house, e&m installations and gardening, including watch & ward of complete area of bps with 2nos of apd ( semiskilled ) and 3nos of beldar ( unskilled ) for each bps ( deployment period 90days ) total no. of shift of a.p.d ( semiskilled ) 63 b part: total no. of shift of beldar ( unskilled ) ...

Delhi Jal Board - Delhi

30684605 supply installation testing commissioningof enm equipments and allied works at sec 23 pkt 7 bps dwarka. a part: s / o monobloc pump set 15 hp, 3 phase, 100x100mm, 2900 rpm approx, cl impeller. suitable capacity 1635 lpm, 28mtr head. make: kbl / m&p / jyoti / lubi / djb approved make 2 vertical dewatering submersible pump 3 hp, 3 phase, del. size 50 mm, 2900 rpm approx. ci impeller, head 10 mtr. make: kbl / m&p / jyoti / lubi / djb approved make 3 self priming motor coupled monoblock pumpset 3 hp, 3 phase, ci impeller, 50x50 mm, 10 mtr. head approx, make : kbl / m&p / jyoti / lubi / djb approved make 4 fabrication of ms base frame for above 15hp mono block pump set made from ms channelwith cross support and also fixing with ms vertical support u channeland 6nos drilling for foundation bolt as per site requirement. 5 fabrication of ms base frame for 3 hp self priming motor coupled monoblock pumpset made from ms channelwith cross support and also fixing with ms vertical support u channeland 6nos drilling for foundation bolt or as per site requirement. 6 supply of 300 ltr water storage tank for vacuum pumpset. make: syntex / isi / djb approved make. 7 s / o ci / di flanged foot valves200 mm dia, pn 0.2 ( as per is: 4038 ) make: kbl / ivc / vag / dorot / djb approved make 8 s / o di d / f sluice valve200 mm dia with ss spindle, pn 6 10 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 9 s / o di d / f sluice valve 100 mm dia with ss spindle, 1.0 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 10 s / o di d / f non return valve 100 mm dia, pn 1.0, ( as per is: 5312 ) make: kbl / ivc / vag / dorot / djb approved make 11 s / o gun metal gate valve of 50 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make: sant / leader / djb approved make 12 s / o gun metal gate valve of 40 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 13 s / o gun metal gate valve of 25mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 14 s / o gun metal non return valve of 40 mm nominal bore ( screwed end ) make : sant / leader / djb approved make 15 s / o double flanged ms pipe of 200 mm dia conforming to is : 3589 make : jindal / tata / djb approved make 16 s / o double flanged ms pipe of 150 mm dia conforming to is : 3589 / 3259 make : jindal / tata / djb approved make 17 s / o double flanged ms pipe of 100 mm dia conforming to is : 3589 / 3259 make : jindal / tata / djb approved make 18 s / o 50mm dia g.i. pipes complete with g.i. fitting and clamps, confirming to is:3259 make : jindal / tata / djb approved make 19 s / o 40 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 20 s / o 25 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 21 s / o 40mm size bronze glass indicator. make : sant / leader / djb approved make 22 fabrication of various ms standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per site requirement. 23 s / o 200 mm dia flanged joints to double flanged ms pipes and specials 24 s / o 150 mm dia flanged joints to double flanged ms pipes and specials 25 s / o 100 mm dia flanged joints to double flanged ms pipes and specials 26 s / o 100 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 27 s / o 150 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 28 s / o nuts bolts and washers of required size. 29 s / o neoprene packing. 30 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 35 sq mm ( forincoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 31 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 25 sq mm ( forincoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 32 2.0 mm electrical rubber mat 1x2 mtr, voltage gradeup to 3.3 kv ac & 240 v dc. isi marked ( as per is: 15652 / 2006 ) make: djb approved make 33 pressure gauge ( bourdon type ) , dial size 100 mm, analog type, material ss, measuring range : 0 7 kg / cm2 or as per site requirement make: h guru / fiebig / djb approved make 34 float and board type water tank level indicator suitable for ugr of depth 4.5 mtr 35 supplying and installing ms perforated cable trays of size 150 mm width x 50 mm depth x 1.6 mm thickness painted with powder coatingwith perforation not more than 17.5%, in convenient sections, joined with connectors, supported by 25 mm x 25 mm x 3 mm iron angleincluding bolts & nuts, painting with primer and finish paint. dsr ( e&m ) 4.1.2 36 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade offollowing size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thick saddle ) 37 making of rcc foundation of the monoblock pump set by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation 38 making of rcc foundation of self priming motor coupled pumpset by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation. 39 installation and fixing of the above pumpsets on the base frame includingjointing the pumpsets with suction / delivery line with proper alignment. the job also include fixing of valves , laying of cable and making thimbling of cable on both ends by 50sq. mm 6 nos thimbles, making connection the pump sets from starter / panel etc i / c watch and ward, cartage , painting of the suction delivery lines, ci valves, specials, ms base frame with good quality enamel paint after two coats of red oxide primer, loading and unloading taking all safety precaution arrangement, all tools and tackles the work including testing and commissioning all e&m equipment i / c various pumpsets at no load and full load in the presence of engineer in charge 40 earthing with g.i. earth plate 600 mm x 600 mm x6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 41 supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm ) 42 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x 2.5 sq. mm + 1x 2.5 sq. mm earth wire 43 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x4 sq. mm + 1x 4 sg. mm earth wire 44 supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5 / 6 a & 15 / 16 a socket outlet and 15 / 16 a piano type switch, connections, painting etc. as required. 45 supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole dsr e&m 2018 2.10.1 46 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted mccb, mcb & dbs including earthing etc. as required. ( but without mcb / rccb / isolator ) 4 way ( 4 + 12 ) , double door dsr ( e&m ) 2018 2.4.1 47 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 48 dcp type fire extinguisher 6 kg capacity suitable to fight abc type & electrically started fire, iso certified 49 shock treatment chart multicolour with rollers, size 5ox70cm approx. 50 fire fighting chart multicolour with rollers, size 37 70x100 mm approx. 51 electrical insulated rubber hand gloves tested for 11 kv isi marked ( as per is: 4770 ) make: djb approved make 52 metal first aid box b type contains following items: ( bandage, cotton, medical tape, anteseptic, pain reliever, antibiotic ointment, cough syrup, etc. ) as per relevent is specifications 53 supplying of fire buckets of 20 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters fire in blackand gold. cost shall be inclusive of providing ms stand portable type duly painted over a coat of primer. ( one stand shall be suitable for hanging 4 buckets ) ( as per is:2546 ) 54 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 55 exhaust fan 18 heavy duty for industrial use make: bajaj / crompton / philips / havells / djb approved make 56 supply of ceiling fan, 5 star rating 1200 mm blade size with regulator make: havells / crompton / bajaj / orient or any other djb approved make. 57 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto30cm ) with 1.5 sq.mm frls pvc insulated, copper conductor, single core cable etc. as required. dsr 2018 1.44 58 indoor lighting, suspended luminaire pendant typeled, 36 40w, 4 ft. length, white make bajaj / crompton / philips / havells / djb approved make 59 external lighting, streetlight led 45 w with suitabie clamp and support as required at site, white make : bajaj / crompton / philips / havells / djb approved make 60 supplying and fixing of 32 mm dia x 2.00 metres long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 61 lt distribution panel 1 ) distribution panel sheet steel enclosure made out of 2mm crca sheet totally enclosed, size 1200 x 900 x 350 mm having canopy powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. the each part of the fabricated panel will be strictly subjected to seven tank treatment .the various components, assemblies and sub equipments of the panel will be as per standard given in relevant is. the bus bar of the panel will be shaped out of high conductivity, electrolytic aluminum conductor and shall be liberal sized. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a ferule crimped to the wire. – 1 no.2 ) mccb 415v, tp 3phase 50h2, 100amp 1 no. make l&t / siemens 3 ) mcb 415v, tp 3phase 50hz, 6 32 amp 2 nos. make l&t / siemens 4 ) mcb 415v, tp 3phase 50hz, 63 amp 2 nos. make l&t / siemens 5 ) mcb single pole 6 amp. 6 nos. 6 ) mpp type power capacitor 7kvar unit 440v 3phase. 2 nos. make epcos7 ) power contactor 220v 3phase 50amp. 6 nos. make l&t / siemens8 ) power contactor 220v 3phase 18amp. 2 nos. make l&t / siemens9 ) over load relay 4 10samp 2 nos. make l&t / siemens 10 ) over load relay 20 33amp 2 nos. make l&t / siemens 11 ) amp. meter digital type 5 nos. make : l&t / ae 12 ) volt meter0 500v digital type 1 no. make l&t / ae 13 ) indicating lights ryb & on 7 nos. make havells / l&t 14 ) push button on / off with elements 8 nos. make l&t / sg 15 ) current transformer100 / 5 3 nos. make ae / saviour 16 ) fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect. loading , unloading by crane or heavy labor and cartage up to site dismantling of old panel structure including removing of cable etc. from site , cleaning & dressing the surface for installation of the panel at site on base frame laying of cable , termination of cable both incoming &out going side 1 job 17 ) installation of the panel at site, termination of cable both incoming &out going side through cable gland & thimble 1 job 18 ) loading, unloading & labour charges & cartage up to site 1 job19 ) testing & commissioning of panel & allied accessories as per required parameters with relevant is.testing of the panel prior to switching on as follow: 1 job i ) continuity and earth testing ii ) meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth 62 b part: maintain water supply of sec 23 pkt 4 bpss. the work includes operation of pump sets as per prevalent schedule and as change time to time on daily basis as per direction of engineer in charge, lt panel and all other electrical and mechanical equipments to maintain the water supply in the command area. the work including minor maintenance of e&m equipments like tightening the glands, greasing, dust blowing & misc. electrical work like replacement of bulb, tubelight, thimbles, etc. ( material will be provided by the deptt. ) , cleaning & sweeping of pump house, e&m installations and gardening, including watch & ward of complete area of bps with 2nos of apd ( semiskilled ) and 3nos of beldar ( unskilled ) for each bps ( deployment period 90days ) total no. of shift of a.p.d ( semiskilled ) 63 b part: total no. of shift of beldar ( unskilled ) ...

Delhi Jal Board - Delhi

30684415 supply installation testing commissioning of enm equipments and allied works at sec 23 pkt 9 bps dwarka. a part 1 s / o monoblock pump set 20 hp, 3 phase, 100x80mm, 2900 rpm approx, cl impeller. suitable capacity 1615 lpm, 32 mtr head. make: kbl / m&p / jyoti / lubi / djb approved make 2 set 2 vertical dewatering submersible pump 3 hp, 3 phase, del. size 50 mm, 2900 rpm approx. ci impeller, head 10 mtr. make: kbl / m&p / jyoti / lubi / djb approved make 1 no 3 self priming motor coupled monoblock pumpset 3 hp, 3 phase, ci impeller, 50x50 mm, 10 mtr. head approx, make : kbl / m&p / jyoti / lubi / djb approved make 1 no 4 fabrication of ms base frame for above 20hp mono block pump set made from ms channel with cross support and also fixing with ms vertical support u channel and 6nos drilling for foundation bolt as per site requirement. 2 no 5 fabrication of ms base frame for 3 hp self priming motor coupled monoblock pumpset made from ms channel with cross support and also fixing with ms vertical support u channel and 6nos drilling for foundation bolt or as per site requirement. 1 no 6 supply of 300 ltr water storage tank for vacuum pumpset. make: syntex / isi / djb approved make. 1 no 7 s / o ci / di flanged foot valves 150 mm dia, pn 0.2 ( as per is: 4038 ) make: kbl / ivc / vag / dorot / djb approved make 2 no 8 s / o di d / f sluice valve 100 mm dia with ss spindle, pn 6 10 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 2 no 9 s / o di d / f sluice valve 150 mm dia with ss spindle, 1.0 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 2 no 10 s / o di d / f non return valve 100 mm dia, pn 1.0, ( as per is: 5312 ) make: kbl / ivc / vag / dorot / djb approved make 2 no 11 s / o gun metal gate valve of 50 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make: sant / leader / djb approved make 3 no 12 s / o gun metal gate valve of 40 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 2 no 13 s / o gun metal gate valve of 25mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 1 no 14 s / o gun metal non return valve of 40 mm nominal bore ( screwed end ) make : sant / leader / djb approved make 2 no 15 s / o double flanged ms pipe of 200 mm dia conforming to is : 3589 make : jindal / tata / djb approved make 10 mtr 16 s / o double flanged ms pipe of 150 mm dia conforming to is 20 mtr : 3589 / 3259 make : jindal / tata / djb approved make 17 s / o double flanged ms pipe of 100 mm dia conforming to is : 3589 / 3259 make : jindal / tata / djb approved make 10 mtr 18 s / o 50mm dia g.i. pipes complete with g.i. fitting and clamps, confirming to is:3259 make : jindal / tata / djb approved make 30 mtr 19 s / o 40 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 10 mtr 20 s / o 25 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 10 mtr 21 s / o 40mm size bronze glass indicator. make : sant / leader / djb approved make 02 nos 22 fabrication of various ms standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per site requirement. 300 kgs 23 s / o 200 mm dia flanged joints to double flanged ms pipes and specials 12 no 24 s / o 150 mm dia flanged joints to double flanged ms pipes and specials 16 no 25 s / o 100 mm dia flanged joints to double flanged ms pipes and specials 20 no 26 s / o 100 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 2 no. 27 s / o 150 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 2 no. 28 s / o nuts bolts and washers of required size. 200 kg 29 s / o neoprene packing. 200 kg 30 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 35 sq mm ( for incoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 35 mtr 31 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 25 sq mm ( for incoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 50 mtr 32 2.0 mm electrical rubber mat 1x2 mtr, voltage gradeup to 3.3 kv ac & 240 v dc. isi marked ( as per is: 15652 / 2006 ) make: djb approved make 4 no. 33 pressure gauge ( bourdon type ) , dial size 100 mm, analog type, material ss, measuring range : 0 7 kg / cm2 or as per site requirement make: h guru / fiebig / djb approved make 4 no 34 float and board type water tank level indicator suitable for ugr of depth 4.5 mtr 1 no 35 supplying and installing ms perforated cable trays of size 150 mm width x 50 mm depth x 1.6 mm thickness painted with powder coating with perforation not more than 17.5%, in convenient sections, joined with connectors, supported by 25 30 mtrs mm x 25 mm x 3 mm iron angle including bolts & nuts, painting with primer and finish paint. dsr ( e&m ) 4.1.2 36 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thick saddle ) 85 mtr 37 making of rcc foundation of the monoblock pump set by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation 2 job 38 making of rcc foundation of self priming motor coupled pumpset by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation. 1 job 39 installation and fixing of the above pumpsets on the base frame including jointing the pumpsets with suction / delivery line with proper alignment. the job also include fixing of valves , laying of cable and making thimbling of cable on both ends by 50sq. mm 6 nos thimbles, making connection the pump sets from starter / panel etc i / c watch and ward, cartage , painting of the suction delivery lines, ci valves, specials, ms base frame with good quality enamel paint after two coats of red oxide primer, loading and unloading taking all safety precaution arrangement, all tools and tackles the work including testing and commissioning all e&m equipment i / c various pumpsets at no load and full load in the presence of engineer in charge 1 job 40 earthing with g.i. earth plate 600 mm x 600 mm x6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 1 set 41 supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm ) 20 mtr 42 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x 2.5 sq. mm + 1x 2.5 sq. mm earth wire 60 mtr 43 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x4 sq. mm + 1x 4 sg. mm earth wire 60 mtr 44 supplying and fixing metal box of 180 mm x 100 mm x 60 3 no mm deep ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5 / 6 a & 15 / 16 a socket outlet and 15 / 16 a piano type switch, connections, painting etc. as required. 45 supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole dsr e&m 2018 2.10.1 6 each 46 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted mccb, mcb & dbs including earthing etc. as required. ( but without mcb / rccb / isolator ) 4 way ( 4 + 12 ) , double door dsr ( e&m ) 2018 2.4.1 1 each 47 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1 no 48 dcp type fire extinguisher 6 kg capacity suitable to fight abc type & electrically started fire, iso certified 1 no 49 shock treatment chart multicolour with rollers, size 5ox70cm approx. 1 no 50 fire fighting chart multicolour with rollers, size 37 70x100 mm approx. 1 no 51 electrical insulated rubber hand gloves tested for 11 kv isi marked ( as per is: 4770 ) make: djb approved make 2 pair 52 metal first aid box b type contains following items: ( bandage, cotton, medical tape, anteseptic, pain reliever, antibiotic ointment, cough syrup, etc. ) as per relevent is specifications 1 no. 53 supplying of fire buckets of 20 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters fire in blackand gold. cost shall be inclusive of providing ms stand portable type duly painted over a coat of primer. ( one stand shall be suitable for hanging 4 buckets ) ( as per is:2546 ) 1 set 54 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 15 point 55 exhaust fan 18 heavy duty for industrial use make: bajaj / crompton / philips / havells / djb approved make 1 no 56 supply of ceiling fan, 5 star rating 1200 mm blade size with regulator make: havells / crompton / bajaj / orient or any other djb approved make. 57 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto30cm ) with 1.5 sq.mm frls pvc insulated, copper conductor, single core cable etc. as required. dsr 2018 1.44 2 no 58 indoor lighting, suspended luminaire pendant type led, 36 40w, 4 ft. length, white make bajaj / crompton / philips / havells / djb approved make 4 no 59 external lighting, streetlight led 45 w with suitabie clamp and support as required at site, white make : bajaj / crompton / philips / havells / djb approved make 5 no 60 supplying and fixing of 32 mm dia x 2.00 metres long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 5 no 61 lt distribution panel 1 ) distribution panel sheet steel enclosure made out of 2mm crca sheet totally enclosed, size 1200 x 900 x 350 mm having canopy powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. the each part of the fabricated panel will be strictly subjected to seven tank treatment .the various components, assemblies and sub equipments of the panel will be as per standard given in relevant is. the bus bar of the panel will be shaped out of high conductivity, electrolytic aluminum conductor and shall be liberal sized. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a ferule crimped to the wire. – 1 no. 2 ) mccb 415v, tp 3phase 50h2, 100amp 1 no. make l&t / siemens 3 ) mcb 415v, tp 3phase 50hz, 6 32 amp 2 nos. make l&t / siemens 4 ) mcb 415v, tp 3phase 50hz, 63 amp 2 nos. make l&t / siemens 5 ) mcb single pole 6 amp. 6 nos. 6 ) mpp type power capacitor 7kvar unit 440v 3phase. 2 nos. make epcos 7 ) power contactor 220v 3phase 50amp. 6 nos. make l&t / siemens 8 ) power contactor 220v 3phase 18amp. 2 nos. make l&t / siemens 9 ) over load relay 4 10samp 2 nos. make l&t / siemens 10 ) over load relay 20 33amp 2 nos. make l&t / siemens 11 ) amp. meter digital type 5 nos. make : l&t / ae 12 ) volt meter0 500v digital type 1 no. make l&t / ae 13 ) indicating lights ryb & on 7 nos. make havells / l&t 14 ) push button on / off with elements 8 nos. make l&t / sg 15 ) current transformer100 / 5 3 nos. make ae / saviour 16 ) fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect. loading , unloading by crane or heavy labor and cartage up to site dismantling of old panel structure including removing of cable etc. from site , cleaning & dressing the surface for installation of the panel at site on base frame laying of cable , termination of cable both incoming &out going side 1 job 17 ) installation of the panel at site, termination of cable both incoming &out going side through cable gland & thimble 1 job 18 ) loading, unloading & labour charges & cartage up to site 1 job 19 ) testing & commissioning of panel & allied accessories as per required parameters with relevant is.testing of the panel prior to switching on as follow: 1 job i ) continuity and earth testing ii ) meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth b part 1 maintain water supply of sec 23 pkt 4 bpss. the work includes operation of pump sets as per prevalent schedule and as change time to time on daily basis as per direction of engineer in charge, lt panel and all other electrical and mechanical equipments to maintain the water supply in the command area. the work including minor maintenance of e&m equipments like tightening the glands, greasing, dust blowing & misc. electrical work like replacement of bulb, tubelight, thimbles, etc. ( material will be provided by the deptt. ) , cleaning & sweeping of pump house, e&m installations and gardening, including watch & ward of complete area of bps with 2nos of apd ( semiskilled ) and 3nos of beldar ( unskilled ) for each bps ( deployment period 90days ) total no. of shift of a.p.d ( semiskilled ) 180 shifts 2 total no. of shift of beldar ( unskilled etc...

Delhi Jal Board - Delhi

30684408 supply installation testing commissioning of enm equipments and allied works at sec 23 pkt 4 bps dwarka. 1 a part: s / o monoblock pump set 20 hp, 3 phase, 100x80mm, 2900 rpm approx, cl impeller. suitable capacity 1615 lpm, 32 mtr head. make: kbl / m&p / jyoti / lubi / djb approved make 2 vertical dewatering submersible pump 3 hp, 3 phase, del. size 50 mm, 2900 rpm approx. ci impeller, head 10 mtr. make: kbl / m&p / jyoti / lubi / djb approved make 3 self priming motor coupled monoblock pumpset 3 hp, 3 phase, ci impeller, 50x50 mm, 10 mtr. head approx, make : kbl / m&p / jyoti / lubi / djb approved make 4 fabrication of ms base frame for above 20hp mono block pump set made from ms channelwith cross support and also fixing with ms vertical support u channeland 6nos drilling for foundation bolt as per site requirement. 5 fabrication of ms base frame for 3 hp self priming motor coupled monoblock pumpset made from ms channelwith cross support and also fixing with ms vertical support u channeland 6nos drilling for foundation bolt or as per site requirement. 6 supply of 300 ltr water storage tank for vacuum pumpset. make: syntex / isi / djb approved make. 7 s / o ci / di flanged foot valves150 mm dia, pn 0.2 ( as per is: 4038 ) make: kbl / ivc / vag / dorot / djb approved make 8 s / o di d / f sluice valve100 mm dia with ss spindle, pn 6 10 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 9 s / o di d / f sluice valve 150 mm dia with ss spindle, 1.0 ( as per is:14846 ) make: kbl / ivc / vag / dorot / djb approved make 10 s / o di d / f non return valve 100 mm dia, pn 1.0, ( as per is: 5312 ) make: kbl / ivc / vag / dorot / djb approved make 11 s / o gun metal gate valve of 50 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make: sant / leader / djb approved make 12 s / o gun metal gate valve of 40 mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 13 s / o gun metal gate valve of 25mm nominal bore with c.i. wheel of approved quality ( screwed end ) make : sant / leader / djb approved make 14 s / o gun metal non return valve of 40 mm nominal bore ( screwed end ) make : sant / leader / djb approved make 15 s / o double flanged ms pipe of 200 mm dia conforming to is : 3589 make : jindal / tata / djb approved make 16 s / o double flanged ms pipe of 150 mm dia conforming to is : 3589 / 3259 make : jindal / tata / djb approved make 17 s / o double flanged ms pipe of 100 mm dia conforming to is : 3589 / 3259 make : jindal / tata / djb approved make 18 s / o 50mm dia g.i. pipes complete with g.i. fitting and clamps, confirming to is:3259 make : jindal / tata / djb approved make 19 s / o 40 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 20 s / o 25 mm dia g.i. pipes complete with g.i. fittings and clamps, confirming to is:3259 make : jindal / tata / djb approved make 21 s / o 40mm size bronze glass indicator. make : sant / leader / djb approved make 22 fabrication of various ms standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per site requirement. 23 s / o 200 mm dia flanged joints to double flanged ms pipes and specials 24 s / o 150 mm dia flanged joints to double flanged ms pipes and specials 25 s / o 100 mm dia flanged joints to double flanged ms pipes and specials 26 s / o 100 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 27 s / o 150 mm nominal dia ms dismantling joints of pressure rating pn 1.6 with both side flange end suitable for installation in between flange end pipes. 28 s / o nuts bolts and washers of required size. 29 s / o neoprene packing. 30 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 35 sq mm ( forincoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 31 s / o 1.1kv grade armoured xlpe cable with aluminium conductor isi marked of size 3.5c x 25 sq mm ( forincoming ) ( as per relevant is specifications ) make : polycab / havells / djb approved make 32 2.0 mm electrical rubber mat 1x2 mtr, voltage gradeup to 3.3 kv ac & 240 v dc. isi marked ( as per is: 15652 / 2006 ) make: djb approved make 33 pressure gauge ( bourdon type ) , dial size 100 mm, analog type, material ss, measuring range : 0 7 kg / cm2 or as per site requirement make: h guru / fiebig / djb approved make 34 float and board type water tank level indicator suitable for ugr of depth 4.5 mtr 35 supplying and installing ms perforated cable trays of size 150 mm width x 50 mm depth x 1.6 mm thickness painted with powder coatingwith perforation not more than 17.5%, in convenient sections, joined with connectors, supported by 25 mm x 25 mm x 3 mm iron angleincluding bolts & nuts, painting with primer and finish paint. dsr ( e&m ) 4.1.2 36 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade offollowing size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thick saddle ) 37 making of rcc foundation of the monoblock pump set by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation 38 making of rcc foundation of self priming motor coupled pumpset by cutting the floor level of the pump house up to suitable depth and refilling it with the help of rcc mixture up to suitable height of the suction line including the cost of plastering of newly made foundation and ss foundation bolts of 300 mm length x 25 mm diaetc as required size of foundation. 39 installation and fixing of the above pumpsets on the base frame includingjointing the pumpsets with suction / delivery line with proper alignment. the job also include fixing of valves , laying of cable and making thimbling of cable on both ends by 50sq. mm 6 nos thimbles, making connection the pump sets from starter / panel etc i / c watch and ward, cartage , painting of the suction delivery lines, ci valves, specials, ms base frame with good quality enamel paint after two coats of red oxide primer, loading and unloading taking all safety precaution arrangement, all tools and tackles the work including testing and commissioning all e&m equipment i / c various pumpsets at no load and full load in the presence of engineer in charge 40 earthing with g.i. earth plate 600 mm x 600 mm x6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 41 supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm ) 42 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x 2.5 sq. mm + 1x 2.5 sq. mm earth wire 43 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2x4 sq. mm + 1x 4 sg. mm earth wire 44 supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5 / 6 a & 15 / 16 a socket outlet and 15 / 16 a piano type switch, connections, painting etc. as required. 45 supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole dsr e&m 2018 2.10.1 46 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted mccb, mcb & dbs including earthing etc. as required. ( but without mcb / rccb / isolator ) 4 way ( 4 + 12 ) , double door dsr ( e&m ) 2018 2.4.1 47 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 48 dcp type fire extinguisher 6 kg capacity suitable to fight abc type & electrically started fire, iso certified 49 shock treatment chart multicolour with rollers, size 5ox70cm approx. 50 fire fighting chart multicolour with rollers, size 37 70x100 mm approx. 51 electrical insulated rubber hand gloves tested for 11 kv isi marked ( as per is: 4770 ) make: djb approved make 52 metal first aid box b type contains following items: ( bandage, cotton, medical tape, anteseptic, pain reliever, antibiotic ointment, cough syrup, etc. ) as per relevent is specifications 53 supplying of fire buckets of 20 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters fire in blackand gold. cost shall be inclusive of providing ms stand portable type duly painted over a coat of primer. ( one stand shall be suitable for hanging 4 buckets ) ( as per is:2546 ) 54 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 55 exhaust fan 18 heavy duty for industrial use make: bajaj / crompton / philips / havells / djb approved make 56 supply of ceiling fan, 5 star rating 1200 mm blade size with regulator make: havells / crompton / bajaj / orient or any other djb approved make. 57 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto30cm ) with 1.5 sq.mm frls pvc insulated, copper conductor, single core cable etc. as required. dsr 2018 1.44 58 indoor lighting, suspended luminaire pendant typeled, 36 40w, 4 ft. length, white make bajaj / crompton / philips / havells / djb approved make 59 external lighting, streetlight led 45 w with suitabie clamp and support as required at site, white make : bajaj / crompton / philips / havells / djb approved make 60 supplying and fixing of 32 mm dia x 2.00 metres long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 61 lt distribution panel 1 ) distribution panel sheet steel enclosure made out of 2mm crca sheet totally enclosed, size 1200 x 900 x 350 mm having canopy powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. the each part of the fabricated panel will be strictly subjected to seven tank treatment .the various components, assemblies and sub equipments of the panel will be as per standard given in relevant is. the bus bar of the panel will be shaped out of high conductivity, electrolytic aluminum conductor and shall be liberal sized. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a ferule crimped to the wire. – 1 no.2 ) mccb 415v, tp 3phase 50h2, 100amp 1 no. make l&t / siemens 3 ) mcb 415v, tp 3phase 50hz, 6 32 amp 2 nos. make l&t / siemens 4 ) mcb 415v, tp 3phase 50hz, 63 amp 2 nos. make l&t / siemens 5 ) mcb single pole 6 amp. 6 nos. 6 ) mpp type power capacitor 7kvar unit 440v 3phase. 2 nos. make epcos7 ) power contactor 220v 3phase 50amp. 6 nos. make l&t / siemens8 ) power contactor 220v 3phase 18amp. 2 nos. make l&t / siemens9 ) over load relay 4 10samp 2 nos. make l&t / siemens 10 ) over load relay 20 33amp 2 nos. make l&t / siemens 11 ) amp. meter digital type 5 nos. make : l&t / ae 12 ) volt meter0 500v digital type 1 no. make l&t / ae 13 ) indicating lights ryb & on 7 nos. make havells / l&t 14 ) push button on / off with elements 8 nos. make l&t / sg 15 ) current transformer100 / 5 3 nos. make ae / saviour 16 ) fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect. loading , unloading by crane or heavy labor and cartage up to site dismantling of old panel structure including removing of cable etc. from site , cleaning & dressing the surface for installation of the panel at site on base frame laying of cable , termination of cable both incoming &out going side 1 job 17 ) installation of the panel at site, termination of cable both incoming &out going side through cable gland & thimble 1 job 18 ) loading, unloading & labour charges & cartage up to site 1 job19 ) testing & commissioning of panel & allied accessories as per required parameters with relevant is.testing of the panel prior to switching on as follow: 1 job i ) continuity and earth testing ii ) meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth 62 b part: maintain water supply of sec 23 pkt 4 bpss. the work includes operation of pump sets as per prevalent schedule and as change time to time on daily basis as per direction of engineer in charge, lt panel and all other electrical and mechanical equipments to maintain the water supply in the command area. the work including minor maintenance of e&m equipments like tightening the glands, greasing, dust blowing & misc. electrical work like replacement of bulb, tubelight, thimbles, etc. ( material will be provided by the deptt. ) , cleaning & sweeping of pump house, e&m installations and gardening, including watch & ward of complete area of bps with 2nos of apd ( semiskilled ) and 3nos of beldar ( unskilled ) for each bps ( deployment period 90days ) total no. of shift of a.p.d ( semiskilled ) 63 b part: total no. of shift of beldar ( unskilled ) ...

Border Security Force - Delhi

30573934 bids are invited for suppling , installation testing and commissioning of ac suppling , installation testing and commissioning of cassette tpe air conditioner with cooling capacit of 1.5 ton/4500kcal/hr,3 5 star bee rating, inverter technolo (variable speed),eco freindl refrierent, copper cooling coil, confirming to is:1391 or latest etc including fixing of copper pipes (max 5mtrs), thermal insulation on copper pipes, providin water drain pipes (max 3 mtr) electrical connections with suitable rated pvc insulated copper conductor frls cable etc complete as required. (daikin/carrier/blue star/lg/haier/voltas) , uvgi uvgi air sanitization/ disinfection system for ac , inter connecting cable supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. , inter connecting cable 1 a) 3 x 1.5 sqmm , inter connecting cable 2 b)3 x 4 sqmm , inter connecting cable 3 c)6 x 4 sq mm , sub main wiring wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. , sub main wiring 1 a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire , sub main wiring 2 b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , sub main wiring 3 c) 4 x 4 sq. mm + 2 x 4 sq. mm earth wires , gi box1 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required. , gi box2 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 a modular socket outlet and 2 nos. 5/6 a modular switch, connections etc. as required. (for light plugs to be used in non residential buildings). , gi box3 supplying & fixing suitable si...

Indian Army - Delhi

30540428 bids are invited for split_ac_item_01 supply and installation of air cooled inverter based split ac unit with both heating ( auto deforst ) and cooling functions, air conditioner is electridriven single phase of capacity 2 tr with charged with eco friendly refrigerent and comes with special health filter and all connected accessories and copper tubing from indoor to outdoor and making of hole in any type of wall, including pvc drain pipe from indoor unit upto plinth protection of building , outdoor split ac hanging wall mounted stand and flexible pvc casing pipe minimum 40mm dia covered on all exposed copper insulated pipe line and pvc wire including taking down old split ac complete set of indoor and outdoor ac with rusted stand with connected accessories etc all as specified and directed by eng in charge. , split_ac_item_02 supply and fix copper pipe for inlet and out let , split_ac_item_03 supply and fix drain pipe with nitrile insulation , split_ac_item_04 supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity 4 kva .make: v guard / bluebird , split_ac_item_05 s & fdistribution board ( db ) , double door ( crca sheet ) dust and vermin proof spn 12 way with 200 amps rated copper busbar, neutral bar, earth bar, ip 43 protection, single pole and neutral 240 volts, flush to wall complete all as specified and directed. make : legrand / siemens / schnieder. , split_ac_item_06 s & f mcb spn, c curve, 240 volts, 100 amps complete all as specified and directed. make havells / legrend / crabtree , split_ac_item_07 s & fmcb sp , c curve, 240 volts, 32 amps ( in new & existing mcb db ) complete all as specified and directed. make havells / legrend / crabtree , split_ac_item_08 s&f sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one mcb of capacity 25 amps , 240 volts complete all as specified and directed. make: legrand / seimens / schneider. , split_ac_item_09 m & l sub main wiring using two single corepvc insulated frls cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire and drawing in to pvc conduit. note two runs of 4sqmm copper frls cable & one run of 4.0 sqmm copper cable in and including 25mm pvc conduit medium grade will be measured as one unit. make : anchor / havells / finolex . total quantity : 1...

Public Works Department - Delhi

30206220 supplying and replacement of eandm items rmo of various eandm services at family court building saket, new delhi 110017 during the financial year 2021 22 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. ( make anchor roma / northwest / as per existing switchboard ) 5 / 6 a switch 2 15 / 16 a switch 3 3 pin 5 / 6 a socket outlet 4 6 pin 15 / 16 a socket outlet 5 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required ( make anchor roma / northwest / as per existing switchboard ) 3 x 1.5 sq. mm 6 3 x 4 sq. mm 7 3 x 6 sq. mm 8 supplying, installation, testing & commissioning of 4 feet, 1x20 watt capacity wall mounted led batten fitting with extruded aluminum housing having lumen output 100 lumens / watt in cool daylight ( 5700 k to 6500k ) power factor 0.90, cri 70, surge protection > 2.5 kv with integrated electronic driver i / c connection of wires with l5 sqmm frls pvc insulated wires ete complete as reqd . ( make havells / crompton greaves / polycab / eveready / trilux ) . 9 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required ( group c ) 10 supplying & laying of one number pvc insulated and pvc sheathed / xlpe armoured power cable of 1.1 kv grade of following ways as required. ( make grandlay / polycab / havells ) 3½ x 240 sq. mm on surface 11 3½ x 240 sq. mm in the existing rcc / hume / metal / hdpe pipe / dwc pipe 12 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required 13 supplying and fixing, fresh air fan of 250 mm size suitable 220 volts 50 hz ac supply in the existing opening including, making hole to suit the size of the above fan making good the damage, connection, testing , commissioning etc as required ( make standard / khaitan / bajaj / usha ) 14 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc. in the existing trench, complete as requireda ) 160 mm dia ( od 160 mm & id 135 mm nominal ) 15 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as requireda ) 3½ x 240 sq. mm ( 62mm ) 16 excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter. 17 supplying, installation, testing & commissioning of recess type 34w to 36w full window glare free opal diffuser led panel of size 595x595mm suitable for armstrong / pop / gb ceiling with ms powder coated white housing. total system lumen of 34w to 36w led should be 3300 or above in cool day light ( 5600k to 6500k ) , power factor>0.90, cri ( ra ) >80, complete with all accessories as required with connections. ( make halonix?havells / philips ) 18 supplying & replacement of 120 watt capacity, energy efficient , pressure die cast aluminium housingled flood light fitting with all acessories i.e tee angle , fasteners etc , connection of wires on the existing wall / ceiling i / c testing & commissioning & credit buy back of old dismantled non working flood light etc as reqd as per direction of engineer in charge. ( havells make model no: jetairisfls 120wled757symlt g / trilux, model no lfl ind 12000 857 et / philips / eveready / halonix ) 19 less for dismantling of old non serviceable / non repairable / burnt out items i / c credit / buy back of dismantled items as reqd.assorted size switch / socket / fan regulator / modular plate 20 assorted size pvc insulated copper conductor wires 21 pvc body fresh air fan 22 36 watt led panel 23 120 watt led flood light...

Delhi Jal Board - Delhi

30125124 improvement and electrification work at ace ( dr. ) project, jal sadan. , s / o 20w led batten light. make: bajaj / havells / crompton , s / o 70w led street light. make: bajaj / havells / crompton , s / o 300 mm size exhaust fan.make:havells / orient / crompton , s / o 1200 mm size ceiling fan.make:havells / orient / crompton , s / o 36w flat 2x2 panel led light recessed luminaire. make:havells / bajaj / crompton , s / o pvc / xlpe insulated ( heavy duty ) electrical cable for working voltage up to and including 1100volts to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminum conductor isi marked power cable aluminum for size 10 sq.mm 2 core armored cable. make: havells / polycab / any djb approved make. , wiring for light point / fan point / exhaust fan / call bell point / with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modular switch, connections etc. as required. , supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box / wooden block including connections etc. as required. , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. , laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of 10 sq. mm size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thich saddle ) . , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way, double door , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole , supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 a , supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe ( medium class ) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer andfinish paint etc. as required. , earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal / coke and salt as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required....

Municipal Corporation - Delhi

30082537 construction of malaria store and malaria circle at saidulajab in ward no.71s south zone. sh e.i., fans and compound lighting 1 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required group c 2 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 3 wiring for light / power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 4 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 6 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 7 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 8 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos.3 pin 5 / 6 a modular socket outlet and 2 nos. 5 / 6 a modular switch, connections etc. as required. ( for light plugs to be used in non residential buildings ) . 9 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 10 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door 11 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 12 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 63a 13 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 14 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 15 supply, installation, testing and commissioning of 1200mm sweep bee 5star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation:b, 3 nos blades, 30cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, power factor not less 0.9, service value ( cmm / w ) minimum 6.85, air delivery minimum 215cmm, 350 rpm ( tolerance as per is:374 2019 ) , thd less than 10%, remotte or electronic regulator unit for speed control and all remaining accessories including, safety pin, nut bolts, washers, temperature rise=75 degree c ( max ) , insulation resistance more than 2 mega ohm, suitable for 230v, 50hz, single phase ac supply, earthing etc.complete as required 16 supply of12 ( 300mm ) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as reqd. 17 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.upto 450 mm sweep 18 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 19 s / i / t / c of led tube type luminaire 20 watt rating complete with extruded aluminium batten prewired with high efficient leds with the following a ) total system wattage 20 watt + / 5% b ) luminous efficacy lumens / watt =95 c ) power factor =.95. 20 p / f circular / hexagonal cast iron of ms sheet box ceilling fan clamp of internal dia 140 mm, 73 mm height top lid of 1.5 thick ms sheet with its top surface hacked for proper bounding top lid shall be screwed into the cast iron / ms sheet box by means of 3.3 mm dia round headed screwed one lock at the corner, clamps shall be made of 12 mm dia ms bar bend to shape as standard drawing. 21 providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) in foundation of pump, dg set etc including form work etc as required. 22 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 a, 16 ka, tpmccb 23 400 a, 50ka, fpmccb 24 supply, installation, testing and commissioning of power distrbution board made out of 1.6mm sheet steel, epoxy powder coated, specially designed al bus bar 400ato 630a with heat shrinkable colour coded sleeves suitable for accomadating mccb / mcbs / isolators as incomimg and outgoing as required ( without mccbs / mcbs / isolators ) complete with digital meter module, including voltmeter, ammeter with selector switch, cts control fuse and indicating lights including coonections etc.as required ( conforms to is:8623 ) 25 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 26 supply, installation, testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240 / 415 volts, 50 hz ac supply. ( a ) 1 hp ( 0.75 kw ) single phase pump set, head from 12 30 mtr. suction and delivery 25x25 mm. 27 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge. 50 mm nominal outer dia pipes 28 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 29 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 30 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 31 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 32 supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm ) 33 supply of xlpe insulated, pvc sheathed al.conductor armoured cable 1.1 kv conforming to is 7098 / 1988 of following sizes ( a ) 3.5x 240sqmm 34 supply of xlpe insulated, pvc sheathed al.conductor armoured cable 1.1 kv conforming to is 7098 / 1988 of following sizes ( a ) 2 x 10sqmm 35 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal pipe as required.upto 35sqmm 36 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. 37 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm ( clamped with 1mm thick saddle ) 38 drilling and laying i / c hdpe pipe of 40mm outer dia with pn4 rating by trenchless technology confirming to is 4984 39 supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width x 50 mm depth x 1.6 mm thickness 40 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia ( od 90 mm & id 76 mm nominal ) 41 fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from ht steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i / c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i / c providing and welding 3 nos. gi strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on din channel i / cpdg and fixing din channel of suitable length, , 6 amp. spmcb ‘c’ characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable.logo / name of manufacturer shall be embossed on the pole.galvanization as per relevant is. 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick. 42 7.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick. 43 providing and laying in position m25 grade reinforced cement concrete foundation of size 450 mm ( l ) x 450 mm wide and 1000 mm deep i / c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia 960mm long ( approx. ) 8 nos.and reinforcement of cold twisted bar of 8 mm dia 1400 mm ( approx. ) 6 nos. ( with 150 mm spacing ) as required with supplying andpositioning of 4 nosfoundation bolts of size 16mm dia and 600 mm long, j type i / c 2 nos. template anchor plates of size225x225x3 mm and providing dcw hdpe for cable entry and exit as required for 3m and 5 mtr pole. 44 providing and laying in position m25 grade reinforced cement concrete foundation of size 600 mm ( l ) x 600 mm wide and 1200 mm deep i / c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia 960mm long ( approx. ) 8 nos.and reinforcement of cold twisted bar of 8 mm dia 1600 mm ( approx. ) 6 nos. ( with 150 mm spacing ) as required with supplying andpositioning of 4 nosfoundation bolts of size 20mm dia and 750 mm long, j type i / c 2 nos. template anchor plates of size225x225x3 mm and providing dcw hdpe for cable entry and exit as required for 7m and 8 mtr pole. 45 fabrication supplyiing and fixing b class galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap 1000mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd. 46 fabrication supplyiing and fixing b class galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap 1000mm long 40 mm dia galvanized pipe with tightening bolts complete as reqd. 47 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 3 x 2.5 sq. mm 48 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 3½ x 240 sq. mm ( 62mm ) 49 2 x 10 sq. mm ( 19mm ) 50 supplying and installation of 4 kva rating voltage stablizer with input voltage:single phase sine wave ( 120 260v ) and output voltage:single phase sine wave ( 210 250v ) complete as reqd. 51 supplying & fixing of full stainless steel body self contained drinking water cooler with cooling cpacity:150 ltr per hr storage capacity:150ltr & suitable 230v supply as reqd. 52 supplying and installation of reverse osmosis ( ro ) water purifier of capacity 50ltr / hr complete as required 53 supply of inverter split air conditioner with rotary air compressor ( r 32 / 290 refrigerant.100% copper condensor, rated cooloing capacity upto:6300 ( w ) , rating 2 ton complete with outer unit as required ( 5 star rated ) 54 supply of extra refrigerant copper pipe as required 55 supply of extra drainage pipe as required 56 supply of extra electric wire as required.the size and material of the wire should be same as of the flexible cable which comes with the air conditioner 57 supply of iron stand as required 58 installation charges of split air conditioner 59 supplying and fixing following rating, four pole, ( three phase and neutral ) , 415 volts, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 63a 60 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required.1 pair 61 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm 62 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.telephone socket outlet...

Department Of Defence - Delhi

30013231 bids are invited for boq1 m&l for sub main wiring with two single core 6.0 sqmm pvc casing caping insulated frls multistranded copper conductor cable drawing into and including rigid non metallic pvc conduit, medium grade isi marked with all conduit fittings & fixing accessories and one single core 6.0 sqmm multistranded copper conductor cable as continuous earth wire complete ass as specified and directed by engr in charge , boq2 m&lfor sub main wiring with two single core 4.0 sqmm pvc casing caping insulated frls multistranded copper condu tor cable drawing into and including rigid non metallic pvc conduit, medium grade isi marked with all conduit fittings & fixing accessories and one single core 4.0 sqmm multistranded copper conductor cable as continuous earth wire complete all asmspecified and directed by engr in charge , boq3 s&f for single pole & neutral sheet metal enclosures for dbs 8 way, 240 v single door complete all as specified and diretcted by engr in charge , boq4 s&f for vertical type load line disrtibution board, double door, 4 way ac 3 phase 415 volts tpn bus bar 200 amp rating and earth bus and din rail suitable to accommodate mccb 100 / 125ampcomplete all as specified and directed by engr in charge , boq5 s&f for mccb, 4 pole 160a, 25 ka complete all as specfied and directed by engr in charge , boq6 s&f of mcb sp 6 32 a, 10 ka complete all as spcified and directed by engr in charge , boq7 s&f of mcb tpn 63 a, 10 ka complete all as spcified and directed by engr in charge , boq8 s&f of mcb spn 40 a, 10 ka complete all as spcified and directed by engr in charge , boq9 s&f for single pole & neutral enclosures with two pin and earth plug and socket complete with one single pole mcb 20amps, 240 v complete all as specified and diretcted by engr in charge , boq10 m&l for earthing complete for bldg with copper plate electrode 60cmx60cmx3.15mm thick buried directly in ground ( earth pit not less than 2.25 meters below ground level ) with top edge of earth plate not less than 1.5 meters below ground level connected to 20x3mmcopper strip as earthing lead by means of nuts, bolts, thimbles, check nuts , washers of gi or steel, pcc ( concrete chamber of size 300mm x300mmx300mm inside dimension ) shall be pcc 1:3:6 type c 1 ( using 20mmgraded crushed stone aggregate ) with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in cm1:4, funnel with wire gauge of 22 gauge , 8 mesh per liner inch, 80 mm thick pcc pit cover 320mmx320mm of rcc 1:2:4 type b 1 ( using 20 mm garded crushedstone aggregate ) reinforced with xpm, jalli and charcoal dust and common salt all as shown in electrical plate no 5 of mes ssr part i ( 2020 ) and specifed including provision of earth wire protected by 15 mm dia medium grade gi pipeand watering gi pipe shall be 20mm bore medium grade etc complete all excavation and earth work and connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specifed and directed by engr in charge total quantity : 1...