Department Of Defence Research And Development - Delhi

38643163 tender for halo residual gas analyzer and accessories. hiden halo 201 rc system, type 142100, with mass range to 200 amu and with dual faraday / channel plate electron multiplier detector radially symmetric, uhv compatible ion source ion source controller: allow the user to control, set and scan the emission, ion energy and electron energy of the mass spectrometer ion source. laptop 17, 8gb ram, 512 ssd, 1xrj45, 2xusb 2.0 twin filament for std. source oxide coated iridium, type 201200 filament changing kit for std. source with 3 oxide coated iridium filaments, type 201600 rf / controller cable 8 mx2, type 250108 multiplier supply cable for halo systems 8 mx2, type 270108 lan cable 8m lengthx2 additional msiu unit...

Council Of Scientific And Industrial Research - Delhi

36125930 procurement of consumables for cf irms instrument , 200009117 sicapent with indicator 500 ml , 200003416 pressure regulator, 0 30 psi , 200000067 valve, solenoid, normally closed, 24v , 200000003 valve, movpt, 1 / 50 , 200003083 isoprime ion source maintenance kit , 200004031 ionisation filament , 200015296 maintenance kit for vario pyro cube , 200009077 leakage set , 200010245 corundum balls for elemental analysis, 50g , 200005872 silver wool for elemental analysis, 50 g , 200001071 block filament support , 200006379 tool kit for ball valve , 200000914 ferrule grap. ves. 1 / 16 x 0.003 0.004 , 200000272 set of consumables for approx. 4000 solid samples cns...

All India Institute Of Medical Sciences - Delhi

33312424 purchase of gas chromatography mass spectrometer ( gc ms / ms ) purchase of gas chromatography mass spectrometer ( gc ms / ms ) , gas chromatography mass spectrometer ( gc ms / ms ) , rate of consumables to be fixed for 5 year , auto sampler vials ( complete set ) , headspace vials , glass inserts split , glass inserts split less , ferrules for supplied columns , calibration standards for mass spectrometer , test mix for gc ms / ms , injector liners for split , injector liners for split less injector , septa for gc injectors , filaments for ms ei , filaments for ms ci , vacuum pump oil , auto sampler liquid syringes ( 5 ul ) , headspace syringe ( 2.5 ml capacity ) , necessary tool kit for routine maintenance of gc ms / ms , tuning solution pftba , spme fiber , quecher kit for sample preparation of 5000 samples , probe vials , probe liner and liner o ring , ion source...

MINISTRY OF HUMAN RESOURCE DEVELOPMENT - Delhi

29011561 bids are invited for boq total quantity : 1 1. gas chromatograph column oven can accommodate two columns with maximum temperature range up to 450 degree c with set point resolution of 0.1 degree c. it should support 20 ramps or more and 21 plateaus or more with & maximum temperature ramp rate of 100 degree c / min or higher. negative ramps should also be allowed. cool down of oven from 450 degree c to 50 degree c within 5 min or less. should have retention time locking feature provision to install two or more columns should have 5 independently heated zones 2. injectors two capillary split / splitless injector for split, split less with fully epc and pressure range up to 100 p.s.i. or higher maximum temperature should be 400 degree c or higher maximum split ratio 7500:1 or higher 3. back flash should quote separate post column or mid column backflash. replacement of gc column without venting ms vacuum which results in elimination of gc / ms downtime. 4. detectors fid with fully epc – 1 nos. minimum detection level of 2 pg c / s or less with either octane / dodecane / tridecane maximum operating temperature 450 degree c or higher dynamic range: > 10^7 or higher minimum detectable level: 1.2 pg c / sec or better with tridecane tcd with fully epc maximum operating temperature 400 degree c or higher dynamic range: > 10^5 or higher minimum detectable level: 400 pg tridecane / ml 5. sample injection device 1. auto injector with 12 or more sample vials 2. 6 port automatic as well as heated gas sampling valve for gas injection. 6. mass spectrometer inert ei source with maximum temperature of 350 °c or higher. higher temp will be preferred. dual filament. electron energy up to 200 ev. quadrupole: heated will be preferred mass resolution of unit mass detector: triple axis detector with high energy dynode and long life electron multiplier transfer line temperature: 100–350 °c or higher ion source temperature: 150–350 °c or higher ei source should be inert to active compounds and should be programmable with maximum temperature of 350 °c or more should be future upgradable to ci mode as well. should have auto tunes feature, one click auto tune for bfb, dftpp, pftba 7. mass range mass range of 2 1000 amu or higher. 8. scan rate scan rate of 20000 amu / sec. 9. sensitivity ei scan sensitivity at least 1500:1, injection of 1pg / μl ofn standard scanning from 50 to 300 amu at nominal 272 ei sim instrument detection limit of 10 fg or less using 100 fg / μl ofn standard at nominal 272 u ion should be demonstrated at site with 30 m column 10 10. turbo molecular pump single turbo molecular pump with capacity of 250l / sec or more and a mechanical pump must be provided for auxiliary pumping 11. library latest 2020 nist library with license version. company should provide license number of nist 2020. 12. software original software with license to control gcms and other accessories. 13. ups suitable 10 kva ups with 30 minutes’ backup and three years’ standard warranty. 14. pc suitable windows 10 based pc workstation with preloaded software from the manufacturer compatible with data acquisition and analysis. the system should satisfy the following minimum specification: intel core i7, 1tb hard disc, 8 gb ram with xeon processor or better, antivirus and 21 inch monitor ( 2 nos. screen ) . 15. printer laser jet color or b / w printer...

Indian Institute Of Technology - Delhi

8448073 tender for lium liquid metal ion source and electron source for quanta 3d feg focused ion beam machine in the department of mechanical engineering....