Jawaharlal Nehru University - Delhi

40417899 tender for up gradation of pumping station of hostels area of entire jnu campus nit no. jnu / engg. / 16 / 2023 24; 1 supply, installation, testing and commissioning of electric motor drivenmonobloc water pump sets suitable for the under mentioned components, capacities and specifications: a ) pump: 30 20 m³ / hr at 20 35meterhead capacitymonoblock single or multi stage having ci casing, ci impeller, shaft sleeve of aisi 410, wearing rings of ci impeller , bronze nuts, shaft of ss 410 directly coupled to motor. .b ) motor: copper woundinduction motor totally enclosed fan cooled type of 5 hp / 3.7 kw for operation on 415v± 10% 50 hz, 3 phase a.c. power supply conforming to is: 325 and with b class insulation. c ) base plate: fabricated from suitable structural m.s. channel as per manufacturer’s / jnu engineer’s recommendations for mounting both pump and motor there on dulyfinished and painted with synthetic enamelled paint, nut & bolts etc.for complete motor & pump set. d ) foundation : suitable c.c. pump foundation as per manufacturer’s design anti vibration ( cushy foot ) heavy duty mounting pads of approved design duly finished with cement plaster etc. e ) priming arrangement : priming arrangement with suitable size of gi pipe , union, socket , elbow etc. complete as required from dischargeline to pump casinginlcuding dismataling of old existingpump sets , gi pipes, valves, foundation etc complete as required. 2 sitcof copper wound ( horizontal, centrifugal, open well submersible ) monobloc pump with prime mover. power rating: 5hp ( 3.7kw ) . type of current: ac ( alternate current ) . number of phase: three phase. voltage: 415v. frequency: 50hz. no of pole: 2poles. type of duty: s1. winding insulation: polypropylene insulated winding wire. type of rotor: aluminum die cast. ingressprotection: ip68. class of insulation: b. type of liquid: clear cold water. specific gravityof liquid to handled: 1. head range: 14 to 28 meters. discharge range: 6.5 to 15 lps ( liters per second ) at 2900rpm ( revolution per minute ) material of construction: motor body: cast iron ( fg 200 ) , pump casing – cast iron ( fg 200 ) , impeller: cast iron, shaft: stainless steel, strainer: stainless steel i / c dismantling of old pump complete as required i / c dismantling of existing monosubmerible pumpat site and storing at site / transporting to the store etc as required. 3 sitcof copper wound ( horizontal, centrifugal, open well submersible ) monobloc pump with prime mover. power rating: 10hp ( 7.5 kw ) . type of current: ac ( alternate current ) . number of phase: three phase. voltage: 415v. frequency: 50hz. no of pole: 2poles. type of duty: s1. winding insulation: polypropylene insulated winding wire. type of rotor: aluminum die cast. ingress protection: ip68. class of insulation: b. type of liquid: clear cold water. specific gravity of liquid to handled: 1. head range: 14 to 40 meters. discharge range: 9.5 to 20.6 lps ( liters per second ) at 2880 / 2900rpm ( revolution per minute ) .material of construction: motor body: cast iron ( fg 200 ) , pump casing – cast iron ( fg 200 ) , impeller: cast iron, shaft: stainless steel, strainer: stainless steel i / c dismantling of old pump complete as requiredi / c dismantling of existing monosubmerible pumpat site and storing at site / transporting to the store etc as required. 4 sitc of wall / floor mounted cubical type motor starterpanel board made of 14 swg crca sheet fully compartmentalized duly dust & vermin proof painted & phosphatized with 7 tank process, complete with following switch gear mounted there of earthing, connection, interconnection, sign writing etc as required. ( depth up to 500mm ) ( for jhelum pump & sabarmati pump room ) incoming a. 100a, 25 ka, 3 pole thermalmagnet release mccb – 01 no. with neutral link.b. ryb indicating led lights with toggle switc h 01 set c. 96 mm2 led digital voltmeter andwith selector switch& class 1 accuracywith– 01 setbusbar a. 200 a capacity, 4 strip aluminum bus bar – 01 no.outgoing a. 40 a, 10ka, tpmcb– 4 nos.b. 5 h.p pump motor dol startercomplete with ac3 duty 50amp rating 3 pole power contractors , no, nc contacts, start, stop push button, start stop indication lamp, degital led ammeter of 96mmx96mm with suitable ct, s ( class 1 accuracy ) , 2.4 amp to 12 amp rating motor protection relayhavingfeature ofoverload protection, locked rotor protection, single phasing protection, phaseunbalance protection, , etc. completewith control wiringas required 4setc. 40 amp dp mcb 02 nosi / c dismantling of existing lt panel / motor starters / switchgears etc. at site and storing at site / transporting to the store etc as required. 5 sitc of wall / floor mounted cubical type motor starterpanel board made of 14 swg crca sheet fully compartmentalized duly dust & vermin proof painted & phosphatized with 7 tank process, complete with following switch gear mounted there of earthing, connection, interconnection, sign writing etc as required. ( depth up to 500mm ) ( for tapti & godavari hostel pump ) incoming a. 100a, 25 ka, 3 pole thermalmagnet release mccb – 01 no. with neutral link.b. ryb indicating led lights with toggle switc h 01 set c. 96 mm2 led digital voltmeter andwith selector switch& class 1 accuracywith– 01 set busbar a. 200 a capacity, 4 strip aluminum bus bar – 01 no.outgoing a. 40 a, 10ka, tpmcb– 2 nos.b. 5 h.p pump motor dol startercomplete with ac3 duty 50amp rating 3 pole power contractorsno, nc contacts, start, stop push button, start stop indication lamp, degital led ammeter of 96mmx96mm with suitable ct, s ( class 1 accuracy ) , motor protection relayhavingfeature ofoverload protection, locked rotor protection, single phasing protection, phaseunbalance protection, , etc. completewith control wiringas required 02setc. 40 amp dp mcb 02 nos i / c dismantling of existing lt panel / motor starters / switchgears etc. at site and storing at site / transporting to the store etc as required. 6 sitc of wall / floor mounted out door type cubical type motor starterpanel board made of 14 swg crca sheet fully compartmentalized duly dust & vermin proof painted & phosphatized with 7 tank process including p / f suitable size angle iron base / legs on bottom complete with following switch gear mounted there of earthing, connection, interconnection, sign writing etc as required. ( depth up to 500mm ) ( for kaveri& periyar hostel pump ) incoming a. 100a, 25 ka, 3 pole thermalmagnet release mccb – 01 no. with neutral link.b. ryb indicating led lights with toggle switc h 01 set c. 96 mm2 led digital voltmeter andwith selector switch& class 1 accuracywith– 01 setbusbar a. 200 a capacity, 4 strip aluminum bus bar – 01 no.outgoinga. 40 a, 10ka, tpmcb– 2 nos.b. 5 h.p pump motor dol startercomplete with ac3 duty 50amp rating 3 pole power contractorsno, nc contacts, start, stop push button, start stop indication lamp, degital led ammeter of 96mmx96mm with suitable ct, s ( class 1 accuracy ) , motor protection relayhavingfeature ofoverload protection, locked rotor protection, single phasing protection, phaseunbalance protection, , etc. completewith control wiringas required 02 set c. 40 amp dp mcb 02 nos i / c dismantling of existing lt panel / motor starters / switchgears etc. at site and storing at site / transporting to the store etc as required. 7 sitc of wall / floor mounted cubical type motor starterpanel board made of 14 swg crca sheet fully compartmentalized duly dust & vermin proof painted & phosphatized with 7 tank process, complete with following switch gear mounted there of earthing, connection, interconnection, sign writing etc as required. ( depth up to 500mm ) ( lohit pump house ) incoming a. 160 , 25 ka, 3 pole adjustable thermalmagnet release mccb – 01 no. with neutral link.b. ryb indicating led lights with toggle switc h 01 set c. 0 400 ampcapacity 96 mm2 led digital voltmeter with selector switch& class 1 accuracy– 01 set busbar a. 300 a capacity, 4 strip aluminum bus bar – 01 no.outgoing a. 63 amp 25 ka3 pole adjustable thermalmagnet releasemccb– 3 nos.b. 40 a, 10ka, tpmcb– 3 nos. c. 10 h.p pump motor star delta startercomplete with ac3 duty 70 amp to 80 amp ratingpower contractors , timer, no, nc contacts, start, stop push button, start stop indication lamp, degital led ammeter of 96mmx96mm with suitable ct, s ( class 1 accuracy ) , motor protection relay of suitable ratinghavingfeature ofoverload protection, earth fault protection, locked rotor protection, single phasing protection, current unbalance protection, phase sequence reversal protection, undercurrent protection etc. completewith control wiringas required 3 setd. 5 h.p pump motor dol startercomplete with ac3 duty 50amp rating 3 pole power contractors , no, nc contacts, start, stop push button, start stop indication lamp, degital led ammeter of 96mmx96mm with suitable ct, s ( class 1 accuracy ) , motor protection relay havingfeature ofoverload protection, locked rotor protection, single phasing protection, phaseunbalance protection, , etc. completewith control wiringas required 3set e 40 amp dp mcb 02 nos.i / c dismantling of existing lt panel / motor starters / switchgears etc. at site and storing at site / transporting to the store etc as required. 8 sitc of wall / floor mounted out door type cubical type motor starterpanel board made of 14 swg crca sheet fully compartmentalized duly dust & vermin proof painted & phosphatized with 7 tank process including p / f suitable size angle iron base / legs on bottom complete with following switch gear mounted there of earthing, connection, interconnection, sign writing etc as required. ( depth up to 500mm ) ( for old crs, academic staff college, bph pump & old mahanadi ) incoming a. 125a, 25 ka, 3 pole adjustable thermalmagnet release mccb – 01 no. with neutral link.b. ryb indicating led lights with toggle switc h 01 set c. 0 400 ampcapacity 96 mm2 led digital voltmeter with selector switch& class 1 accuracy– 01 set busbar a. 200 a capacity, 4 strip aluminum bus bar – 01 no.outgoing a. 63 amp 25ka3 pole adjustable thermalmagnet releasemccb–2 nos.b. 10 h.p pump motor star delta startercomplete with ac3 duty 70 amp to 80 amp ratingpower contractors , timer, no, nc contacts, start, stop push button, start stop indication lamp, degital led ammeter of 96mmx96mm with suitable ct, s ( class 1 accuracy ) , motor protection relay of suitable ratinghavingfeature ofoverload protection, earth fault protection, locked rotor protection, single phasing protection, current unbalance protection, phase sequence reversal protection, undercurrent protection etc. completewith control wiringas required 2 set i / c dismantling of existing outdoor feeder pillar at site and storing at site / transporting to the store etc as required. 9 sitc of sumersible pump set of discharge 5 14 m3 / hr , head 55 102 mtr. rating of motor=5hp 2900 rpm suitable to operate on 400v±10%, 50hz ac supply complete with lifting of old submesible pump with old pipe upto150 240 ft depth and lowering ofnew pump setupto the depth between 150 ft. 200 ft. in the existing borewell i / c providing & fixing gasket, nut & bolt at every 10 ft. lenght of existing pipe of50 mm dia gi flange with connection, interconnection etc complete asrequired. 10 sitc of wall / floor mounted out door type cubical type submersible pump starterpanel board made of 14 swg crca sheet fully compartmentalized duly dust & vermin proof painted & phosphatized with 7 tank process including p / f suitable size angle iron base / legs on bottom complete with following switch gear mounted there of earthing, connection, interconnection, sign writing etc as required. ( depth up to 500mm ) ( sports complex & p.s rock ) incoming a. 63a, 25 ka, 3 pole thermalmagnet release mccb – 01 no. with neutral link.b. ryb indicating led lights with toggle switc h 01 set c. 96 mm2 led digital voltmeter andwith selector switch& class 1 accuracywith– 01 setbusbara. 100 a capacity, 4 strip aluminum bus bar – 01 no.outgoing a ) . 5 h.p pump motor dol submersible pump startercomplete with ac3 duty 50amp rating 3 / 4 poleheavy dutypower contractorsno, nc contacts, start, stop push button, start stop indication lamp, degital led ammeter of 96mmx96mm with suitable ct, s ( class 1 accuracy ) , over loadrelay, single phase preventer , auto start switch, 3 position selector switch for spp auto / spp manual / manualetc. completewith control wiringas required 01set 11 supply &laying of 3 core 4 sq mm pvc insulated& pvc sheathedcopper flat submersible cable in the existing pipe with connection, interconnection etc complete as required. 12 reinstallation , testing & commissioning of old5hp monoblock pump setin the new pump house / old pump housei / c making suitable foundation with 1:3:6cement concrete and priming arrangementwith suitable size of gi pipe , union, socket , elbow etc.from drain line to pump i / cp / f 4 nos anti vibration padsetc.complete as required. 13 supply& layingof1100 volts rated aluminium conductor steel wire / strip armored xlpepower cable of following sizes as per is 7098 part iwith isi markedonexisting cable trayincludingtesting at manufacturer site etc complete as required. 14 3 core 10sq. mm. armoured aluminium cable. 15 3.5 core70sq. mm. armoured aluminium cable. 16 3.5 core120sq. mm. armoured aluminium cable. 17 supply& layingof1100 volts rated aluminium conductor steel wire / strip armored xlpepower cable of following sizes as per is 7098 part iwith isi markedin theexistingrcc / hume / metal / hdpepipeincludingtesting at manufacturer site etc complete as required. 18 3 core 10sq. mm. armoured aluminium cable. 19 3.5 core70sq. mm. armoured aluminium cable. 20 3.5 core120sq. mm. armoured aluminium cable. 21 supply& layingof1100 volts rated aluminium conductor steel wire / strip armored xlpepower cable of following sizes as per is 7098 part iwith isi markedon wall surfaceincludingtesting at manufacturer site etc complete as required. 22 3 core 10sq. mm. armoured aluminium cable. 23 3.5 core70sq. mm. armoured aluminium cable. 24 3.5 core120sq. mm. armoured aluminium cable. 25 providing and fixing of following sizecast iron foot valve , having flange end connections with matching flange, pressed fibre gasket and nut bolts washers and of size matching the pump suction complete as required 26 65 mm 27 80mm dia 28 providing, laying, testing & commissioning of b class heavy duty g.i. pipe conforming to is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 29 50 mm nb medium class ( b class ) 30 65 mm nb medium class ( b class ) 31 80 mm nb medium class ( b class ) 32 supplying, fixing, testing & commissioning of double flanged sluice valve of rating pn 1.6 with non rising spindle, bronze / gun metal seat, isi marked complete with nuts, bolts, washers, gaskets and conforming to is 780 of following sizes as required. 33 50 mm dia 34 65mm dia 35 80mm dia 36 providing, installation, testing and commissioning of non return valve of following sizes confirming to is: 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 37 50 mm dia 38 65mm dia 39 80mm dia 40 supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, uspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspenders etc. as required. 41 100 mm width x 50 mm depth x 1.6 mm thickness 42 supplying and making indoor and termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 43 3x 10 sq.mm. ( 25mm ) 44 3½ x 70 sq. mm ( 38 mm ) 45 3½ x 120 sq. mm ( 45 mm ) 46 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 47 2 x 6 sq. mm 48 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required 49 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 50 63 mm dia ( od 63 mm & id 51 mm nominal ) 51 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thickincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required 52 supplying and laying 25 mm x 5 mm g.i strip at 0.50 meterbelow ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50 mm ) 53 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i.pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required. 54 excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter....

Military Engineer Services - Delhi

40319565 provision of certain sanction work in the area of age b / r i and age e / m under ge ( central ) delhi cantt 10 1 excavation in trenches n exc 1.5 mtr wide & n exc 1.5 mtr deep and getting out in soft / loose soil 2 m&l pcc ( 1:5:10 ) type e 2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified. 3 m&l for brickwork with subclass b bricks, straight or cirved on plan exc 6mtr mean radius, built in cement mortar 1:6. 4 s&f pre painted galvalume aluminium zinc coating gi based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified. 5 s&f mild steel rolled section or hollow pipes ( square or round pipe ) as in main and cross beam, hip and jack rafter, purlins, where connected to common rafter and running rails fixed with cleat or other connecting plates etc. complete all as specifed and directed. 6 m&l painting two coats of synthetic enamel paint over a coat of red exide including preparation of new steel surfaces of any description over 10cm in width or grith not other wise described. complete all as specified and directed. 7 m&l providing cm 1:2:4type b 0 12.5 mm graded agg. in precast lintels inclincluding necessary form work complete. 8 m&l for tmt bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.90mm dia or securing with clips. 9 m&l for tmt bars 5mmand over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.90mm dia or securing with clips as in stirrups, spaces and binders. 10 m&l for rendering 15mm thick on fair faces of brick or concrete surface in cement mortar 1:6 mixed with integral water proofing compound. 11 solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with ms square tube, supplying and fixing in opening as per specification & drawing. 12 factory made solid panel pvc door shutter 30mm thick ( style ) consisting of frame made out of ms tubes for top & bottomrails. ms frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour pvc sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail ; panelling of plain colour pvc sheet to be fitted in the ms frame welde / sealed to the styles and rails with suitable pvc sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing. 13 s&f steel ventilator with top hung shutter including hinges, steel peg stay including two coats of synthetic enamel paint over a coat of red oxide primer complete. 14 s&f galvanised mild steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm & fixed with tinned tacks or galvanised wire staples. 15 s&f 150mm aluminium anodised barrel tower bolts of extruded section and fixed. 16 s&f 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed. 17 s&f 125mm aluminium handles, cast type , anodised and pattern / design as approved. 18 s&f ms butt hinges medium wt of size 100 mm complete all as specified and directed. 19 demolition of cement concrete ( unreinforced ) in ground floors and pavings n.exc 15cm thickness ( below or above ground level ) . 20 m&l for 25mm thick cement concrete type b 0 1:2:4 ( 12.5mm graded aggregate ) as in sub floor. 21 m&l for non skid ceramic tiles, coloured, 7 to 8 mm thick ( square / rectangular ) area of each tile exceeding 0.11 sq m but not exceeding 0.18sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified. 22 m&l non skid ceramic coloured tiles 7 to 8mm thick ( square / rectangular ) area of each tile n. exc. 0.11 sqm but exc. 0.18 sqm, in wall, skirting etc set and jointed in neat cement slury & pointed in coloured cement to match laid over a 10mm thick rendering in cm 1:4. 23 m&l vitrified ceramic light shade coloured tiles 10mm thick square / rectungular polished area of each tile not exceeding o.36 sqm in floor etc set and jointed in neat cement sluarg and painted in white or coloured cement to match laid over 15mm thick screed bed of cm 1:6 . 24 ditto as item no 16above but as in skirting over rendering 10mm thick in cement mortar 1:4. 25 taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 26 m&l 15mm thick rendering on any face fair faces of brick work or concrete surfacesin cement mortar 1:4 finsihed the surfaces even and smoothwithout using extra cement. 27 m&l glazed ceramic coloured tiles 450mm x 300mm x 6 to 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick bedding layer in cement mortar ( 1:4 ) including necessary cutting as per site requirement complete all as specified and directed by engineer in charge. 28 m&l 50mm thick pcc 1:2:4type b 1 using 20mm crushed stone aggregate as in plinth protection and like finished even and smooth without using extra cement. 29 m&l for preparation of new plastered wall surfaces and applying three coats of white wash. 30 m&l for preparation of new plastered wall surfaces and applying two coats ofcement base paint 31 s&f vitreous china wash down water closet pan ( pedestal pattern ) , white, including flush pipe of polyethylene of low or high density or pvc 32 mm dia., plastic water closet seat closed pattern with cover and hinging device and trap with connection in repairscomplete all as specified. 32 s&f chromium plated jet for ewc complete all as specified. 33 s&f in repairs vitreous china wash hand basin, white, flat back, size 550 x 400 mm including fixing with brackets exclusive of fixing of supply and waste pipe and 32 mm chromium plate waste fitting with long screwed shanks and fly nuts complete all as specified. 34 s&f pvc valve less syphonic action type low level flushing cistern white of capacity 10 ltrs with inlet valve float and fixed to water closet with pvc flushing pipe 32mm dia 35 s&f in repairs pvc connections 15 mm size with ptmt nuts of length 450 mm in repairscomplete all as specified. 36 s&f brass chromium plated shower rose 125mm size for iron pipe or for unions and fixed to 15 mm bore steel tube in repairscomplete all as specified. 37 s&f in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified. 38 s&f bib taps, cast copper alloy, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore steel tube fixed in repaircomplete all as specified. 39 s&frotational moulded polythylene water strarge tanks 500 ltr ( cylinderical vertical with closed top ) hoisted and fiexed in position all as per specified in ssr pt 1. 40 s&f15mm boretubes medium grade , galvanised, with all fittings, and fixed complete to walls and ceilings or laid in floors 41 s&f 15mm bore stop valve / angle valve cast copper alloy chromium plated fancy type screwed down, high pressure, with crutch or butter fly handles fixed in repairs. 42 s&f 20mm bore brass ball valves, high pressure, with polythene float and flynut complete , screwed for iron pipe or brass ferrule and fixed. 43 s&f 110mm bore pvc ( swr ) soil, waste and vent pipe, in any length , with rubber joints, laid in trenches or in floors. 44 s&f pvc ( swr ) 110mm bore bend of any radius. 45 s&f in repairs pvc ( swr ) bends ( 75mm bore ) including jointingwith solvent cement complete all as specified. 46 s&f 75mm bore pvc ( swr ) soil, waste and vent pipe, in any length , with rubber joints, fixed vetically on wall. 47 s&f pvc ( swr ) floor traps 75mm bore and jointing to waste pipe in solvent cement. 48 s&f in repairs pvc ( swr ) vent cowl of 110 mm bore. 49 s&f in repairs pvc ( swr ) vent cowl of 75 mm bore. 50 s&f in repairs pvc ( swr ) junction double, ( double t, 110 mm bore ) , equal or unequal , including jointingwith solventcement complete 51 s&f in repairs pvc ( swr ) junction double, ( double t , 75 mm bore ) , equal or unequal complete, including jointingwith solvent cement. 52 s&f sink with drainage board made out of 1.00mm thick sheet for kitchen with plug, washers, waste pipe including connecting union overall size 1145mm x 510mm x 200mm with bowl size 510mm x 400mm x 200 mm including taking out existing china ware sink with waste fittings complete all as specified. 53 surface excavation n.exc ( not exceeding ) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed. 54 m&l pcc ( 1:4:8 ) type d 2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified. 55 sand filling under floors or in foundations incl. watering and consolidation. 56 m&l 60mm thick interlocking paver block with grey cement and with pigment of any size and shape confirming to is 15658 2006, m 35 grade as approved by e i c laid in flooring and joints filled / broomed with fine sand. 57 m&l for pcc 1:3:6 type c1 using 20 mm graded stone aggrgate as in coping to wallcomplete all as specifed and as directed. 58 taking down chowkats or frames exc. 1.5sqm but n.exc 4 sqm eachwith shutters ( without taking off shutters from frames ) , complete all as specified. 59 taking down chowkats or frames n.exc. 1.5 sqm ( without taking off shutters from the frame ) . 60 s&f steel windows with side hung shutters incl box type hing, steel handle and peg stay complete with glazing bar. 61 all as per item no 61 abovebut without glazing bars. 62 m&l two coats of syntheticenamal paint to steel surfaces of any discription over 10 cm width or girth not otherwise described after preparation complete. 63 s&f pressed steel frames, size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc.. 64 s&f pressed steel frames, size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. 65 providing cement concrete type c 0 1:3:6 ( 12.5 mm graded agg ) as for pressed steel chowkhats. 66 s & f 30 mm thickflush shuttersolid core construction, with block board core and plywood face panels, commercials type on both sides complete all as specified. 67 s&f factory made 35mm thick second class hard wood glazed and skelton door shutters , open rebated and prepare to receive glass, gauge etc, size of members of shutters as specifed in ssr part i, section 8 clause 8.24 ( b ) . 68 m&l two coats of synthetic enamel painting on wooden surfaces not otherwise described over 10cm width or girth over a coat of pink primer inclding prepration of newly untreates surfacescomplete all as specified and directed. 69 supply only butt hinges, 100mm medium weight, cold rolled mild steel. 70 m&l cement concrete 1:4:8 type d 2 using 40mm graded stone agg as in bed to drain pipe, incl packing under and haunching against the sides of pipe 150mm bore after they are laid and tested. 71 m&l, 150mm internal dia salt glazed storeware drain pipes laid in treanches and jointed as secified. 72 m&l for precast manhole cover rcc 1:2:4 type b 1 using 20mm graded stone agg as in cover slab and like axcept set in cement mortor 1:4 complete incl necessary form work. 73 returning filling in including spreading, levelling, watering and well ramming in layers n exc 25 thick in soil. 74 removal of surplus spoil to a distance exc 50 mtr and n exc 100 mtr and depositing where directed at a level n exc 1.5 mtr above starting point in soil. 75 m&l for providing 75 mm thick cement concrete1:2:4 type b2 ( 40 mm graded aggregate ) as in hard standing laid in alternate bays complete all as specified and directed by engineer in charge. 76 m&l three coats white wash on ceiling undecorated surfaces including prepration of newly plastere surfaces. 77 m& l for applyingtwo coats of oil bound distemper onnew wall surface with roller brushcomplete all as specified and directed. 78 s& f ms framed work such as grills, gratings etc., with ends of bars shouldered and / or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to fe 290 or fe 165 complete all as specified and as directed. 79 s&f powder coated anodiesed aluminium frame for partition, doors, windows, ventilators with one or more rebates incl. joining cleat for fixing etc. complete all as specified. 80 s&f powder coated anodiesed aluminium door shutters, aluminium section weighing 0.55 kg / m incl. necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 nos in each doors, brass 2 lever mortice lock verticle type size 100mm, hinges, anodiesed aluminium snap beading screw withetc. 81 s&f powder coated not less than50micron anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg / m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long ( 1 no. ) hinge type b 21 100mm long ( 2 no. ) suitable handle ( 1 no. ) complete all as specified 82 s&f anodised aluminium grill ( anodised transparent or dyed to required shade according to is :1868 with minimum anodiccoating of grade ac 15 ) of approved design / pattern, with approved stadandered section and fixed to existing window frame with cp brass / stainless steel screws @200mm c / c, incl cutting the grill to proper opening size for ficing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction of engineer in charge. 83 s&f 4.8 mm thick sheet glass, ordinary quality and glazing in aluminium partition, door or window with solar control files 50 micronin squares exc 0.5 sqmeach pane. 84 s&f door closer aluminium ( extruded section ) hydraulically regulated designation no. 03, universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kgs. 85 supply and fixing floor door stopper 140mm long of aluminium alloy and tongue, anodised with hard drawn steel spring fixed in floor etc completeall as specified & directed by engineer in charge. 86 demolition of brick work or stone masonry built in cement mortar in any position including segregating serviceable / unserviceable bricks / stones complete all as specified and directed by engineer in charge. 87 supply & fixing steel water tubes of size 15mm bore ( medium grade ) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors / concealed in wallscomplete, all as specified & directed by engineer in charge. 88 s&f15mm dia brass chromium plated mixer for mixing hot and cold water screwed down for iron pipe and fixed to whb including taking out existing mixer from old whb, complete all as specified. 89 s&f 15mm dia brass chromium plated two in one wall mixer for mixing hot and cold water screwed down for iron pipe and fixed to wall and shower, complete all as specified. 90 s & f in repaircp health faucets with crutch or push handle, screwed down with 1.5mtr cp flexible pipe, screwed for pipe, 15mm dia, fancy type, cast copper alloy. chromium plated long body completeall as speciifed. 91 s & f in repairs glass corner 300 mm radius of 10mm thick toughned glasswith cp brassrailng, fixed with screws fancy type, complete all as specified . 92 s & fixedin repairpvc mirror cabinetmade of high intensity polythene of biggar size 500 x 400 x 120 mm complete all as specified. 93 s&fin repairbrass chromium platedtoilet paper holder, complete all as specified. 94 s&f stainless steel gratings 100mm bore size fixed with cement motar complete all as specified. 95 s&f in repair brass chromium plated soap dish, complete all as specified. 96 s&f in repair stainless steel peg set of 06 peg, 45 centimeter long, complete all as specified. 97 s&f in brass chromium plated tubular towel rail, 20mm dia, 60cm long between flange including brackets. 98 s&f in brass chromium platedtowel rack60cm long between flange including brackets. 99 s&f in repair pvcfloor trap square type with cockroch proofing cp grating with or without hole including provision ofjointing to waste pipes in run lead joint dia of outlet 75 mm, complete all as specified. 100 s&f anodised aluminium snap grade of size 600 x 600mm frame work for false ceiling all as specified. 101 s&f hangers 6mm dia g i ( upto 1200mm length ) asjusting level fixed to roof slabs by means of ceiling cleats made out of g i flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long. 102 exposed metal frame ceiling with 8mm thick calcium silicate board of silicious and calcareous material reinforced with cellulose fibre for fixing in 600mmx600mm grid ( frame work for ceiling shall be measured and paid seprately ) . 103 s&fcurtain rod made out of 25mm dia ( outer dia ) pipe having thickness 0.63mm , pvc coated and colour / pattern, over all dia 28 to 29 mm including brackets complete all as specified and directed. 104 excavating in post holessoft / loose soil ( or similar holes ) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, 105 m&l for steel work in tubular trusses including special shaped washer etc. complete using erw or induction butt welded tubes complete all as specified and directed. 106 dismantling boarding any description ( board / plywood ) fixed in any position with screw, complete all as specified. 107 s&f pvc 18 / 19mm thick pvc moulded solid board, one side prelaminated for cabinet boxes, shutters etc. with shelf and shutters full size fitted under / above kitchen cooking platform and other platform complete all as direction of the engr in charge and the manufacturers specifications and drawings. 108 s&f continuous ( piano ) hinges, mild steel, bright finish or electrogalvanised, width of flaps ( when open ) 30 mm, complete all as specified. 109 s&f ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified. 110 s&f stainless steel handle of size 150mm size long complete all as specified. 111 supply and fix 40mm dia, cup board knobs fixed with nuts, screw and washer of brass polished , complete all as specified. 112 m&l for 2nd class hardwood plain, solid straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, complete all as specified. 113 s&f stainless steel handle of size 200mm size long complete all as specified. 114 s&f 300mm long, stainless steel of aisi 316 grade, sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and fixed, complete all as specified. 115 s&f brass chromium plated magic eye complete all as specified. 116 supply and fix150mm mild steel ordinary rat tail rod pattern springs including roller and roller plateincluding welding where ever necessary complete all as specified and directed. 117 demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, all as specified. 118 m&l for rectified coloured ceramic tiles 300x600 x 7 to 8mm thick, as in vertical surfaces of wall as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in cm 1:4 all as directed. 119 m&l for rectified coloured ceramic tile 300x300x6 8 mm thickas in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm thick screed bed in cm 1:6 complete all as directed. 120 dismantling floor, hearthwall tile incl cement mortar bedding ( but not backing ) removing serviceable tiles and rubbish out of premises, all as specified. 121 material and labour for preparation of new plastered surfaces as of walls and applying twocoats of weather proofing exterior acrylic emulsion paint of duluxweather shield max or apex ultima from asian paintover one coat of primer from the same manufacturerwhite lime wash complete all as specified and directed. 122 dismantling of 100 mm dia cast iron pipe ( soil / waste / vent ) with fittings etc fixed to walls, ceiling, on floors & from trenches if requiredincluding taking out any type of joints complete all as specified. 123 all as per item 124 above but 75mm dia 124 s&fsteel windows including pressed steel frame made of 1.25 mm thick ms sheet of size 125x60 mm double rebated with side hung shutter both glaze, gauge and guard bars of 12mm square bars placed horizontally / vertically @ 125mm c / c , including box type hinges steel handless and peg stay , tower bolts and including glaze / gauge and guard bars dovetailed or welded , incl one shop coat of red oxide primer ( wire gause and glass pan shall be measured seperately ) . incl m&l for providing pcc 1:2:4 ( 12.5mm graded stone aggregate ) to fill the frame and making good complete all as specified and directed by engineer in charge . 125 m& l for preparing the entire surface withapplying2 3 mm thick birla / jk wall care putty on walls surface finished even and smoothcomplete all as specified and directed.putty to be procured directly from manufacture.. ( item is executed in stage and passed. ) 126 s & f in repairs stainless steel of ae si 316 grade 100 mm size mortice lock vertical type, 4 levers with key in duplicate, incl 2 no suitable handle fixed to shutters with screws, complete all as specified. 127 supply and fix in repair chromium plated brass angle valve dual type suitable for 15mm bore pipe, complete all as specified. 128 s&fin repair 15mm dia brass chromium platedsink mixer for mixing hot and cold water screwed down for iron pipe and fixed to kitchen sink including taking out existing mixer , complete all as specified. 129 s&f mild steel as in hand rail, balusters, noising to steps, post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, drilling, bolting or riveting etc, conforming to fe 290 , gde e 165 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by engineer in charge. 130 supply only 3.15 mm dia galvanised steel chain link fencing, 100x100 mm mesh, made up into mattrsses or cages, lapped, wired a all as specified. 131 fixing only chain link fencing including line wires any mesh, size and type to any to any type of standard, rail, straining bolts, etc. including provn of winding wire all as specified. 132 m&l mild steel round bars 10 mm dia conforming to fe 410 w ( gde e 250 ) quality a or fe 290 ( gde e 165 ) for use in chain link fencing as wind tie all as specified. 133 mild steel screw bolts ( machine made ) with hexagonal or square heads at one end screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 30 cm and dia of neack exc 12 mm but not exc 20 mm complete all as specified and as directed by engineer in charge. 134 s&fsteel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets ( for securing wire mesh etc. ) including all necessary drilling, bolting or riveting, etc., and similar work conforming to fe 290 gde e 165 complete all as specified and directed. 135 s&f 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with srew. 136 m&l providing and applying the plaster with single component ready to use repair mortar ( smart care repair mortar or equivalent ) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: sbr polymer ( @ 10% of cement weight ) modified cementious bond coat @ 2.2 kg cement / sqm of surface area mixed with specified portion of ap smartcare or equivalent repair polymer including taking down existing roof treatment of any type including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed. note: the application shall be executed on any type of surface and on horizontal / vertical areas. 137 m&l providing and applying smartcare dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having sun reflectivity index ( sri ) of 105 on horizontal / vertical surfaces of roof / wall / chajas in multiple coats @2.0 litre / sqm. primary [ coat is self priming coat of elastomeric waterproofing liquid ( dilution with water in the ratio of 3:1, damp proof : water ) and other coats to be applied undiluted. the coating needs to be reinforced with 40 gsm geotextile, to sandwiched between 2nd & 3rd coat of coating. the application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of engineer in charge. 138 taking up or down 15 mm dia gi tubing and connections including cleaning for re fixing, complete all as specified. 139 m&l for rendering 15mm thick in cement mortar 1:4 withtwo coat of tape create mixed ( 1:2 ) withcement paste @ 500 gm per sqm as per manufacturere instructionin sunken portion of toilets, finished even and smooth without using extra cement and applying a coat of hot blown bitumen 85 / 25 grade as the rate of 0.70 kg per sqm and applying one coat of hot blown bitumen 85 / 25 grade at the rate of 2.6 kg per sqm and one layer of 0.5mm thick fibre tissue over it and finally third layer of hot blown bitumen 85 / 25 grade at the rate of 2kg per sqm including getting out, complete all as specified. 140 s&f in repair vitreous chinaware coloured oval shape wash hand basin ( whb ) size 550mm x 400mm complete, ist quality, including provision of pair of mild steel angle iron brackets of suitable size duly painted and cutting for and pinning in ends of brackets in walls & making good & including providing and fixing of suitablewaste pipe and waste fitting complete all as specified. 141 s&f in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide withbrass chromium plated bracket guard and railing 60cm long. 142 cutting holes in brick wall built in cement mortar for inserting hold fasts, depth of embedded postion of hold fast / lugs measured from the face thejambs into the wall exc half brick but n.exc one brick thick and making good the dismantaled portion in cement mortar 1:3 or in cement concrete 1:2:4 type b 1, using 20mm graded stone agg complete all as specified upto six storey height. 143 m&l external endura chequered cement concrete tiles 30cmx 30cmx 10mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 15mm thick screed in cement mortar 1:6 144 m & l for one light / fan point controlled by one switch wiring complete with, pvc insulated and unsheathed cable 1.5 sq mm ( nominal area ) multi stranded copper conductor single core conforming to is : 694including medium duty surface conduit unplasticised pvc conduit conforming to is : 9537 ( part 3 ) andisi marked20 mm diawith concealed / cashing cappingin wall pressed steelterminal boxes1.6 mm thick of required. size ( factory made ) with top coverlaminated sheets of required colour for fixing piano switches complete with all accessories and all as specified including pvc insulated and unsheathed cable 1.5 sqmm ( nominal area ) multi stranded copper conductor single core conforming to is : 694 of green colour asearth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified and directed. 145 s & f water heater storage type ( geyser ) vertical type with suitable size of fastner and incl provision and connecting up of ss braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material abs with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 15 ltr having heating element 2 kw and not less than 5 star rating with minimum two year warrant on product, minimum 3 years warranty on heating element and minimum 7 years warranty on inner tank.note : old unservicable geyser will be deposoted in mes yard. 146 s&f led 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass / non yellowing polycarbonate cover, ip65 protection, system level efficacy of the luminary is > 90 lm / w with a life class of 50, 000 burning hours at l70 criteria, power factor >0.95, driver with voltage range 150 270v, temperature range 0 to 50 deg, driver efficiency >85%, thd<10%, cri>80, color temperature 6000k, surge protection of 2.5 kv, including connecting up with necessary pvc sheathed 3 core 1.5sqmmcopper conductor flexible wire fixed completeallas specified and directed. 147 m&l for ceiling rose, surface polycarbonate isolated body three terminals 148 m&l switch piano flush button type 5 amp sp one way . 149 supply and fixing ventilating fan250 mm sweep, 1250 rpm, non metallic resin body, single phase 240 volts ac 50 hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. 150 supply and fix led batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. cri > 80, power factor > 0.95, thd < 10%, color temperature > 6500 k , surge protection 2.5 kv in cm ip 20 protected meets led is specifications, voltage range 150 to 270 volts ac, temperature range 0 to 50 degree c, system efficiancy at luminarie level =100 lumens / watt and including connecting up with pvc sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. 151 m&l for sub main wiring with two single core frls stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core frls stranded copper conductor cable 4 sqmm for earth wire in and including medium grade pvc concealed conduit with all fittings complete all as specified and directed 152 s&fsheet metal enclosure single pole and neutral with a two pin earth plug and socket complete with a mcb sp 20 amp 220 volts, 50 hz, 10ka breaking capacity complete all as specified and directed. 153 s&f mcb db spn 8 way horizontal, ip 43 protection double door 240 v ac 50hz with for mcbspn as incomer and dp / sp mcbs as out going with tinned copper bus bar , neutral link earth link complete. 154 s&f mcb spn 32 amps 240 volts 10 ka 50 hz c curve complete. 155 s&f mcb sp 6 32 amps 240 volts 10 ka 50 hz c curve complete. 156 supply, laying in repairs of pvc under ground xlpe insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laying in trenches, fixed along wall, through gi pipe under floor complete all as specified and directed. 157 s&f for cable protection gi tubing light grade in trenches / fixed to wall / ceiling including required gi fitting of size 40mm dia complete all as specified and directed. 158 supplying laying and cushioning for cable protection in trenches 18 cm thick layer before laying cable and 15 cm thick layer over the cable including well punning complete all as specified and directed. 159 supplying laying sub class ‘b’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed. 160 s & f wall mounting air circulator fans ac single phase 230 / 240 v, 1440 rpm of size 600 mm sweep ( 24 ) , 180 watt, aluminium alloy three blade, double ball bearing 90° oscillation, sturdy close mesh guard beatifull design, powerful heavy duty motor, air dilivery 270 m³ / min, mounting on wall complete all as specified and directed by engr in charge. 161 m&l distribution board spn8 way with 200 amp rated bus bar double door. 162 m&l distribution board spn12 way with 200 amp rated bus bar double door. 163 m&l mcb spn 40 amp c curve with 10 ka breaking capacity. 164 m&l mcb dp 63 amp c curve with 10 ka breaking capacity. 165 supply and lay cable xlpe insulated screened pvc bedded, galvanized steel strip and wirearmoured , electric power cables ( heany duty ) 1100 volts grade with stranded alumimium conductor of size 16 sqmm 04 core. 166 m&l earthing complete with gielectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level ( with top edge of earthplate not less than 1.50 mtr below normal ground level connected to gi strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm gi tubing light grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt ppc ( 1:2:3 ) type c 1 ( using 20mm graded stone aggregate ) for earth pit with 40 x 40 x 6mm msangle iron frame for cover 40 mm thick ( 1:2:4 ) type b20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm c / c both way with ms handle 20mm dia plastering 15mm thick cm ( 1:6 ) internally externally pgl funnel with ground wire mesh 20mm dia med grade gi pipe for watering complete all as shown on electrical plate no 3 of ssr part 1 2009 and connected in earth test incl testing completed all as specified. and directed. 167 m / l for hard core of guage not exc 63mm with broken stone deposited spread & levelled in layers n.exc 15cm thick, watered & ramed to a true surface. 168 m & l for point wiring complete with 1.5 sqmm single core pvc insulated frls cable 1100 volts grade with multi stranded copper conductor drawn through and including non metalic rigid pvc conduit medium grade isi marked and all conduit accessories concealed in wall / ceiling / fixed to roof / truss / columns etc and including provision of 1.5 sqmm pvc insulated copper cable frls as earth continuty, fabricated branded modular metal flush box / m s steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings: complete all as specified and directed by engineer in charge. 169 one bell / buzzer point controlled by one bell push 170 one 3 pin 5 amps socket outlet point controlled by oneway switch on same board 171 one 3 pin 5 amps socket outlet point controlled by oneway switch on independent board. 172 all as per item no 170 above but point wiring with 4 sqmm single core copper cable and earth continuity wire with 2.5 sqmm single core stranded copper cable for one three pin 15 / 16 a socket outlet point on independent board complete all as specified and directed by engineer in charge. 173 supply and fix led batten luminaire surface mounted, 4 feet system wattage not less than 20 watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. cri>80, power factor > 0.95, thd< 10%, colour temperature 6500k, surge protection 2.5kv in cm, ip 20 protected, meets led is specifications, class 1, short circuit and over circuit protection, voltage range 150 to 270 volts ac, temperature range 0 to 50 degreec andincluding connecting up with pvc sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. 174 supply and fixing led bollard integral decorative with pmma diffuser 10 watt of height 0.6 meterwith ip 65 protection suitable for single phase 230 volts 50 hz ac supply including led bulb , poles, service wire conduit pipe and cement work complete all as specified and directed by engineer in charge. 175 supply and fixing new generation, post top energy saving environmently friendly 25w , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power led as light sources. 176 m&l in replacement socket outlet6 amp flush button type complete all as specified and directed by engineer in charge. 177 s&f not less than 35w high efficient led street light fitting with pressure die cast aluminum housing and has lenses specially designed for street lighting with polycarbonate cover.system level efficacy of the luminarieshould more than 110lm / w. the color temperature is around 6500 k with a color rendering index of 70. the luminaire is ip:66 protected.it has an electronic driver complaint to iec safety standards with a power factor>.0.9, voltage variation range 120 270v, thd<10%, high and low protection along with a surge protection of 4 kv including provision ofsuitable dia gi light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. 178 supply and fix wall mounted fan 400mm size, 230 volts , 50 hz 1420 rpm with 90 degree oscillation and having speed control by pull cord ( two ) system complete all as specified and directed. 179 s&fswitch modular type 6 amps 1 way, 1 module, 230v ac complete all as specified and directed by engineer in charge. 180 m&l for switch modular type 16 amps 1way, 1 module with modular plate light marking 230v ac complete all as specified and directed by engineer in charge. 181 m&l in replacement modular socket outlet 2 / 3 pin 6 / 16amp universal socket 2 module complete all as specified and directed by engineer in charge. 182 s&f modular socket outlet 2 / 3 pin 6 amp socket 2 module complete all as specified and directed by engineer in charge. 183 supply and fixing wall mounted angular electric chimney black colour of suction power not less than 1220cum / hr, al casette with stainless steel outer layer , touch control panel, 3 speedmotor with 250 watt with decorative smart cooker hood ss and glass , energy efficent led light with digital display , including ducting not less than 12 feet as per site required complete all as specified and as directed by engr in charge. 184 strato 2x2 ultra slim recess mounted edgelit led module with high brightness led package and unique pattern acrylic de glaring diffuser sheet for glare free uniform light distrubution suitable for armstrong / grid ceiling.pannel light 185 s & f water heater storage type ( geyser ) vertical type with suitable size of fastner and incl provision and connecting up of ss braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material abs with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 25 ltr having heating element 2 kw and not less than 5 star rating with minimum two year warrant on product.note : old unservicable geyser will be deposoted in mes yard. 186 s&f 15mm bore pillar tap of brass cp. 187 schedule of credit...

Northern Railway - Delhi

39611233 supply of corona resistant wire round enameled winding wire as per rdso spec no. rdso / 2014 / el / spec / 0116, rev 0, size 18 swg ( 1.219 mm ) grade 2. [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

39610738 supply of corona resistant wire round enameled winding wire as per rdso spec no: rdso / 2014 / el / spec / 0116, rev 0, size 20 swg ( 0.914 mm ) grade 2 . [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

39610519 supply of corona resistant wire round enameled winding wire as per rdso spec no. rdso / 2014 / el / spec / 0116, rev 0, size 21 swg ( 0.813 mm ) grade 2. [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

39608251 supply of corona resistant wire round enameled winding wire as per rdso spec no. rdso / 2014 / el / spec / 0116, rev 0, size 23 swg ( 0.61 mm ) grade 2. [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

39584089 supply of corona resistant wire round enameled winding wire as per rdso spec no. rdso / 2014 / el / spec / 0116, rev 0, size 21 swg ( 0.813 mm ) grade 2. [ warranty period: 30 months after the date of delivery ] ...

Indian Army - Delhi

39563862 bids are invited for 5084 mta staniless steel indian type water closet iwc , fiber sheet , non skid tiles , kero heater , steel wire nails assorted , pbs roll , pvc pipe , self threading screw , self threading screw , winding wire , self tapping screw , pvc door total quantity : 915...

Northern Railway - Delhi

38679839 supply of corona resistant wire round enameled winding wire as per rdso spec no: rdso / 2014 / el / spec / 0116, rev 0, size 19.5 swg ( 0.965 mm ) [ warranty period: 30 months after the date of delivery ] ...

Central Public Works Department - Delhi

38432105 auction sale of unserviceable / dismantled material led underwater spot light 6x 3 watt 1x28 watt electronic ballast 2 x 28 watt electronic ballast burnt copper winding wire gland bush bearing 150 mm butterfly valve 24v dc contactor engine starting relay 80 mm dia sluice valve 65 mm dia sluice valve thermal overload relay 50 mm dia butterfly valve 65 mm dia nrv burnt out copper winding wire 80 mm dia elbow led driver 3 watt 4 x 14 watt electronic ballast igniter etc.,...

Northern Railway - Delhi

38060327 supply of corona resistant wire round enameled winding wire as per rdso spec no.rdso / 2014 / el / spec / 0 116, rev 0, size 23 swg ( 0.61 mm ) grade 2. [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

37924009 supply of corona resistant wire round enameled winding wire as per rdso spec no. rdso / 2014 / el / spec / 0116, rev 0, size 21 swg ( 0.813 mm ) grade 2. [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

37922068 supply of corona resistant wire round enameled winding wire as per rdso spec no: rdso / 2014 / el / spec / 0116, rev 0, size 20 swg ( 0.914 mm ) grade 2 . [ warranty period: 30 months after the date of delivery ] ...

Delhi Metro Rail Corporation Limited - Delhi

37405039 auction sale of misc. copper scrap consisting of: ac copper tube, motor winding wire, misc. faulty cables, s bond copper cable, capacitor connecting lug, vrv idu coil, pantograph shunt wire, contactor coil, ballast, jumper, bridle wire and different type of armored cable 6 quad, 1quad, zpau 4pair, etc....

Northern Railway - Delhi

36940205 supply of dual coat round copper winding wire size 17 swg [ 1.4224mm ] nominal diameter conforming to is: 13730 13 / iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [ 1 ] base coat [ pe ] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860 / 35lyc [ 2 ] top coat [ pai ] ai 1013 bv / 35 or allotherm 602 l 35 s. [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

36365231 supply of dual coat super enamelled copper winding wire of size 22 swg confirming to is:13730 part xiii grade 2.dual coat super enamelled copper winding wire of size 22 swg confirming to is:13730 part xiii grade 2., dual coat super enamelled copper winding wire of size 22 swg confirming to is:13730 part xiii grade 2. [ warranty period: 30 months after the date of delivery ] ...

Northern Railway - Delhi

35747032 supply of dual coat round copper winding wire size 20swg [ 0.914mm ] confirming to is: 13730 13 / iec 60317 grade 2 or 2b.enamel for making class 200 wire shall be of dr. beck india ltd. as follows [ 1 ] base coat [ pe ] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860 / 35 lyc [ 2 ] top coat [ pai ] ai 1013 bv / 35 or allortherm 602 l 35 s. [ warranty period: 30 months after the date of delivery ] ...

Military Engineer Services - Delhi

35583751 repair / maintenance of dg sets of various capacities, servicing and maint of eot crane and repair / maintenance of sewage pumps, sewage treatment plant and connected misc e / m items / works at anand parbat mil stn under ge ( north ) delhi cantt 10. comprehensive maintenance of dg sets & amf panel of make as mentioned against each dg sets below including preventive maintenance checks of engine and alternator for trouble free function as per recommendation and attending break down / complaint as and when on required basis, monthly maintenance on regular basis complete with preventive maintenance ( b check ) twice a year including replacement of engine oil / coolant, replacement of required necessary spares and replacement of all types of filters, belts along with rectification of minor defects and cleaning of air filters / breather, coolant tank with blower and labour for filling / topping up and tuning of engine for dg set as listed below complete all as specified and directed. note : the rates quotedagainst for ser item no 1.01 to 1.07items shall be applicable for a period of 01 month. 2 40 kva dg set 01 nos ( location: ranjith hall, make: crompton greaves ) 3 62.5 kva dg set 01 nos ( location: bapa nagar pump house, make: kirloskar ) 4 62.5 kva dg set 01 nos ( location: map ph ii pump house, make: greaves power ) 5 100 kva dg set 01 nos ( location: map ph i pump house, make: jackson / kirloskar ) 6 125 kva dg set 01 nos ( location: amar vihar, make: greaves / kirloskar ) 7 160 kva dg set 01 nos ( location: klp area, make: cumins / stamford ) 8 200 kva dg set 03 nos ( location: deepak vihar, make: greaves power ) 9 notes: ( a ) after monthly maintenance, the work to be certified by je ( e / m ) / engr in charge on job card. ( b ) cost of materials and labour as mentioned in below are not included with comprehensive maintanance. ( c ) the comprehensive maintenance of work shall be done through respective oems or their authorised dealers. ( d ) the contractor shall carry outroutine checking of the complete dg sets and rectify the minor / major defects noticed immediately.if complaints were not attended within one hours a penalty of rs 500 per fault per hour shall be imposed over contractor and shall be deduct from his dues. ( e ) contractor has to carry out monthly maintenance with examination of suction and exhaust valves for smooth operation of dg sets. ( f ) contractor shall be responsible to monitor the followings of alldg sets during comprehensive maintenance andthe cost of same is deemed to be included in the quoted rate: ( i ) examination and cleaning of fuel injection, nozzles. ( ii ) check clearance of suction and exhaust valves and adjust if required, ( iii ) changing of oil filters, fuel filters screen filters assy. ( iv ) maintenance of coolant level all as directed by the engineer in charge. ( v ) change of hydraulic governor oil ( vi ) change of oils ( vii ) clean alternator winding in position by forced air and internal surfaces lubricate de & nde bearings ( viii ) tightining of all nut bolts. ( ix ) greasing of all points. ( x ) test ir value of alternator winding and recording the readings ( xi ) checking of any leaking in fuel & oil lines and rectification of the same. ( xiii ) any other check as reqd for efficient running of equipment all as specified & directed by engr in charge. ( xiv ) the rates quoted against the above mentioned items is deemed to be included for cost of labour, cost of t & p requiredfor replacement of unserviceable parts and cost of handling / transportation of defective item to & from civil workshop for repair if required. spares shall be measured and paid separately under respective items.supply only items labour cost is deemed to be included in this item. ( xv ) in case of break down, the additional manpower if required will be arranged by the contractor. the cost of the same are deemed to be included in the quoted rate. 10 supply only in replacement of v belts for radiator fan / main shaft / cam shaft for the dg set of capacity 40 kvato 200kva as per existing size and model complete all as specified and direceted. 11 supply only in replacement of fuel filters for the dg set of capacity 40 kva to 200kva as per existing size and model complete all as specified and direceted. 12 supply only in replacement of oil lub filters for the dg set of capacity 40 kva 200kva as per existing size and model complete all as specified and direceted. 13 supply only in replacement of air filters for the dg set of capacity 40 kva 200kva as per existing size and model complete all as specified and direceted. 14 supply only in replacement of lubricant oil ( 15w40 ) for the dg set of capacity 40 kva 200kva as per existing size and model complete all as specified and direceted. 15 supply only in replacement of coolant for the dg set of capacity 40 kva 200kva as per existing size and model complete all as specified and direceted. 16 s&f in repairs rewininding with super enamelled copper wire of existing size & insulating the field coil assembly, replacing bentec assembly ofthe self starter assembly 12 / 24 voltsand refixing the same after repairs andtesting complete all as specified. 17 s&f in replacement ofself starter assembly 12 / 24 volts existing size and model andtesting complete all as specified. 18 s&f in repairs lead acid batteries of 12 volts, 110 150 ah, 22 28 plates, maintenance free type including accesories like terminal clamps, copper cable of required size and length, petroleum jelly and baterry initial charging all as specified and as directed. make exide / amar raja / luminious / hbl 19 s&f in repairs battery charger capacity 6 / 12 amp, 12 / 24 voltsfor dg set complete all as specified and directed. 20 m&l for carring out repairs to 12 / 24volt dynamo by replacement of carbon brush, electronic regulator, rectifier, windings, bearings reassembling the same and testing complete all as specified and directed. 21 s&f in replacement aganist repairs of stop solenoid / shut off valve of capacity 40 to 200 kva dg sets of existing make along with screen filterincluding wiring connecting to panel circuit, starting and testing on load complete all as specified and directed. 22 s&f in repairs of thermostat element alongwith complete assy for dg set connection and testing complete all as specified and directed. 23 m&l for repairs and calibration of pt fuel pump as per the calibration procedure and norms as per manufactures guide linesfor dg set of various capacity from40 to 200kvaincluding replacement of worn out and unserviceable o rings / shutt off valve / plungers complete all as specified and directed. 24 s&f in replacement of control assembly fordg set capacity40 to 200 kvawith necessary modification to controll wiring, replacement of controll relays, programming with all the parameters for safety protection and running suitable for the existing dg sets. . 25 s&f in replacement of necessary control wiring for making the auto / manual mode condition of the existing dg sets 40 to 200 kva complete all as specified and directed. 26 s&f in replacement ofautomatic voltage regulator ( avr ) suitable for dg set of 40 kva to 200 kva capacity including taking out old unserviceable avr and making all connection, testing for smooth operation complete all as specified and directed. 27 s&f in replacement of magnetic pickup sensor suitable for 40 200 kva of exist makedg set connecting with panel circuit, starting and testing on load complete all as specified and directed. 28 s&f in replacement of oil pressure sensor suitable for 40 200 kva of make exist dg set connecting with panel circuit, starting and testing on load complete all as specified and directed. 29 s&f in replacement of coolant tempetaruresensor suitable for 40 200 kva of make exist dg set connecting with panel circuit, starting and testing on load complete all as specified and directed. 30 dismantaling the unserviceable radiator from dg set of capacity 40 to 200 kva of exist make andtransporting to contractors workshopfor locating the fault and overhauling & cleaning using air compressor, de scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads, hoses, clamps, clips, etc. and refixing / reassembling its original position after making proper connections, aligning, testing including transporting back the same to site complete all as specified and directed.note : the rates quoted by the contractor shall deemed to include thereplaced spares / parts, transportation cost from site of installation to contractors repair workshop and back. 31 cleaning of diesel tank of various capacity dg set inside / out side oftank complete with drain out dhpp ( n ) and cleaning tank and applying two coats of synthetic enamel paint ( 1st grade quality ) on out side of tank including necessary weldings and refilling the dhpp ( n ) & testing complete all as specified and directed. 32 s&f in repairs of electronic timers with auxilary voltage of 110 / 240 / 415v 50hz for operation of 12 120 secs complete all as specified and directed. 33 s&f in repairs of speed control units 40 to 200 kva dg stes of exist makecomplete all as specified and directed. 34 s&f in repairs auxilary control contactors side mounting add ons ( 1no+1nc ) as per existing capacity at respective site complete all as specified and directed. 35 s&f in replacement of new power contactor of capacity 360 amp 4 pole, 415 volts with side mounting, mcx type auxilary contacts operable at 220 v, 50hz including taking down ofdefective power contactor from amf panel complete all as specified and directed. 36 s&f in replacement of 3 phase digital multi function meter with suitable accessories and fixing arrangements complete all as specified and directed. 37 s&fin replacement of selector switch suitable for 415 volts complete all as specified and directed. 38 s&fin replacament of led type phase indicator to be fitted on panel ( r, y , b as per site requirement ) as per existing model / capacity including taking down of old unserviceable one complete all as specified and directed. 39 s&f in replacment of digital typevoltmeter 0 500volts with selector switch, 3 phase, complete all as specified and directed. 40 s&f in replacment repairs of digital type ammeter 0 200 / 300 amps with 3 nos ct coils and selector switch, 3 pohase complete all as speicified and directed. 41 s&f in replacement for alarm system with complete wiring complete all as specified and directed. 42 s&f in replacment of dg setdoor lock and key assembly suitable for exit dg set doors as per existing model complete all as specified and directed. 43 removal of rusted ms sheet at any portion of canopy and supply and fixing of 3.15 mm thick ms sheet of size 300 mm x 300 mm with fitting / welding as specified and directed. 44 m&l forpainting two coats of synthetic enamel paint of existing colour at site over a coat of red oxide primer for dg sets complete body surfaces complete all as specified and directed. 45 m&l for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground ( earth pit not less than 2.25 meters deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate no. 3 of ssr part i connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft / loose soil, returning filling, disposal od surplus soil, earth pit in pcc 1:3:6 type c 1 using 20mm graded crushed stone aggregate pit, funnel, 20mm bore gi tubing medium grade for watering pipe, 40mm bore medium grade gi pipe for protection of gi earth strip and pre cast earth pit cover 50mm thick made of rcc ( 1:1.5:3 ) type a1 duly reinforced with 8mm dia tmt bar @ 100 mm c / c both ways, one lifting handle made out of 10mm dia tmt bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed. 46 repair of earth pit including required exacavation, earth work and pcc work to make good damaged / disturbed surfaces of earth pit chamber & making new pit cover of rcc 1:2:4 type b 1 using 20mm graded crushed stone aggregate reinforced and lifting handle on rcc cover with 8mm ms bars at 150 mm centre to centre both ways including supply & fixing of wire mesh and funnel including re connection of earth wire / strip with panel / transformer using gi nut, bolts & washer complete all as specified & directed 47 m&l for repair / maint / overhauling long travel mechanism with lubrication lt wheel & gear box, over hauling hoist mechanism with reduction gear box, over hauling cross travel mechanism with gear box, testing & commissioning 5 ton eot crane, replacement of defective any minor parts complete all as specified and directed. 48 m&l for painting of complete eot crane with golden yellow colour paint including writing letters or figures ( block, roman, italic or indian ) n exc. 30 cm high with synthetic enamel paint as per colour scheme all as specified ( make rockwell ) 49 m&l for replacement of pvc flexible cable 1.5 sqmm 16 core copper wire complete all as specified and directed. 50 m&l for replacement of rotary geard limit switch ratio 48:1 complete all as specified and directed. 51 m&l for replacement of lever type limit switch complete all as specified and directed. 52 m&l for replacement of e.m brake ( 200mm ) coil 415v, ac complete all as specified and directed. 53 m&l for replacement of lubrication gear oil no.68 complete all as specified and directed. 54 m&l for replacement of current collector shrouded busbar type complete all as specified and directed. 55 m&l for replacement of 3 pole power contactor type ml4 type complete all as specified and directed. 56 m&l for replacement of hydraulic thrustor brake 300mm 34kg complete all as specified and directed. 57 m&l in replacement of damage ct shaft made out of en8 material medium carbon steeloff size in 80mm x 500mm with various step and key way slot 12mm both side on shaft complete all as specified and directed. 58 m&l in replacement of spherical roller bearing off suitable size complete all as specified and directed. 59 comprehensive maintenance inclding preventive and periodical maintenane and servicing of ro systems complete 03 nos, i.e.500 lph 01 no & 2000 lph 02 nos capacity. make of eukawa & ion exchange with connected motors, upvc pipe lines, butterfly valves, multi port valves etc, respectively, including servicing / cleaning of all filters / back wash etcin reliable safe and efficient condition through oem by periodically examining, preventive maintenance of plants, pipe lines, valves for trouble free function as per recommendation and attending breakdown / complaint as and when on required basis, maintenance on regular basis complete with preventive maintenanceincluding replacement of upvc pipes ( different sizes ) short lengths upto 5 mtrs, fittings, flanges with nut and bolts, pressure gauges, replacement of required necessary fittings alongwith rectification of defects complete all as specified and directed.all as directed. notes : ( i ) the contractor shall carry out routine checking of the complete plants and rectify the any defects noticed immediately ( iii ) treated water tds should be maintained less than 100mg / l and as directed, submit he monthly water test report of treated water. ( iv ) the rates quotedagainst for this item shall be applicable for a period of 01 month. ( v ) rates quoted aginst the above mentioned work wise items are required of efficient working of plant are to be included in the job . ( vi ) unserviceable and consumable parts will be measured and paid seperately unde relevent items as mention in below. ( vii ) if complaints were not rectified within 04 hrs of intimation, the following penalities will be imposed and deducted from contractors dues : ( a ) rs 1500 / per complaint for not attending the complaint and keeping pendig 04 hrs to 12 hrs / per complaint. ( b ) rs 3000 / per complaint for not attending the complaint and keeping 12 hrs to 24 hrs / per complaint. 60 replacement in repairs membrane high pressure, 500 lph.make dow / hydronautics / csm 61 replacement in repairs membrane high pressure, 2000 lph.make as per sample 62 replacement in repairsfor sediment ( sand and silt ) , dirt and rust particles, high efficiency, low pressure drop, removal up to 5 micron filter cartridges suitable 500& 2000lph capacity makes as per existing all as specified and directed. 63 replacement media in sand filter ( gravel, pebbles & fine sand ) complete all as specified and directed. 64 replacement activated carban in barban filter complete all as specified and directed. 65 supply only ro antiscalent high ph for membrane cleaner / water treat ment chemical complete all as specified and directed. 66 replacement in repairs rotameter suitable for 500 / 2000lph capacity ro system. make as per sample. 67 replacement in repairs of upvc pipe 20 to 40 mm dia with fitting complete suitable for ro systemas per sample. 68 replacement in repairs of membrane housing suitable for 500 lph capacity ro system of eukawa make .as per sample 69 replacement in repairs of membrane housing suitable for 2000 lph capacity ro system of ion exchange make .as per sample 70 replacement in repairs of housing bowl suitable for 500 & 2000 lph capacity ro system, make .as per sample. 71 replacement in repairs of lt relay, 230v ac supply suitable for 500 & 2000 lph capacity ro systemmake .as per sample. 72 s&f in reapirs of multi port valves fixing at sand filter and carbon filter vessles all as specified and directed. makes as per sample. 73 s&f, testing and commissioning high pressure pumps for ro plant, vertical type having speed 2780 rpm, 230 v, 2hp, class f insulation, eff 76% complete with fixing necessary accessories including taking down old unserviceable deposit to store yard complete all as specified and as directed. make : cri / crompton / kirloskar. 74 s&f, testing and commissioning self priming regenrative pumps for ro plant, mini star model having speed 2780 rpm, 230 v, 1hp, class b insulation, size 25x25mm, head 6 45 mtrs, dis range 50 lpmwith fixing necessary accessories incl taking down old unsv deposit to store yard complete all as specified and as directed. make : cri / cropmton / kirloskar. 75 s&f in repairs for rotational moulded polyethylene water storage tanks100 ltrs capacity ( cylindrical vertical with closed top in white colour transparent type for using antiscaling chemicals for ro plants ) hoisted and fixed in position all as specified and directed. 76 m&l for disconnection electrical and water connection of the raw water feed monoblock pumpset with motor and base plate and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size / capacity of motors upto3 hp.note : rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning. 77 m&l for disconnection electrical and water connection of the high presuure feed pump, multi stage centrifugal type and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size / capacity of motors upto3 hp.note : rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning. 78 s&f in repairs for antiscalant dosing unit capacity upto 6 lph @ 3.5 bar including inlet and outlet flexible pvc pipes all as specified and directed. 79 s&f in repairs pressure gauges for monitoring of flow meters all as specified and directed. ( makes as per sample ) 80 testing of treated water of stp and submission of detailed test report to the office of the engr in charge and testing in govt approved laboratory as approved. ( a ) carrying out minimum essential testing of water as per is 3025mandatory for chemical, odour, ph value tss bod cod residual chlorine total nitrogen, sulphate, oil and grease ammonical nitrogen ( nh3 n ) and bacteriological total collifrom organisms as below: rest of the characterstied of the treated water shall be as per is : 3025note 1 rate quoted shall deemed to be included for : ( i ) cost of sterilised bottle as required ( ii ) to and fro transportation charges for collection of sample 81 ( i ) tss: < 10 mg / ltrs 82 ( ii ) bod : < 10 mg / ltrs 83 ( iii ) cod :< 150 mg / ltrs 84 ( iv ) ph : 6.5 8.5 85 ( v ) total coliform : , < 100 mpn / 100 ml ( desired nil ) 86 ( vi ) residual ci > 1 mg / ltr 87 rest of the characterstied of the treated water shall be as per is : 3025 88 note 2 rates quoted shall deemed to be included for : 89 ( i ) cost of sterilised bottle as required 90 ( ii ) to and from transportation charges for collection of sample 91 note 3 in case contractor fails to provide monthly test report, a penalty of rs 3000 / per test report shall be recovered from the contractor dues. 92 testing of sewage sludge water as per revlevant is of stp and submission of detailed test report to the office of the engr in charge and testing in govt approved laboratory as approved by ge ( a ) carrying out minimum essential testing of sewage water as per revlevant is mandatory for chemical, odour, ph value tss bod cod total nitrogen, sulphate, oil and grease ammonical nitrogen ( nh3 n ) and bacteriological total collifrom organisms and other charaterstics as per relevant is of sewage water: note 1 rates quoted shall deemed to be included for : ( i ) cost of sterilised bottle as required ( ii ) to and fro transportation charges for collection of sample 93 supply & mixing of sodium hypo choloride having 10% content complete all as specified and directed. 94 supply & mixing of poly aluminium choloride 100% purity complete all as specified and directed. 95 supply & mixing of poly electrolite 100% purity complete all as specified and directed. 96 supply & filling compressor oil 460 complete all as specified and directed. 97 material and labour in replacement of quartz silica sand 32 64 grade complete all as specified and directed. 98 material and labour in replacement of quartz silica sand 16 32 grade complete all as specified and directed. 99 material and labour in replacement of quartz silica sand 8 16 grade complete all as specified and directed. 100 material and labour in replacement of quartz silica sand 4 8 grade complete all as specified and directed. 101 material and labour in replacement of activated carbon iv 1000 complete all as specified and directed. 102 material and labour in replacement of feb ( mbbr ) media suitable for stp make as per sample. 103 taking out complete pebbles from the bottom upto the depth of 0.6 mtr of the filter of size 1800 mm dia and 2300 mm height and refilling the same pebbles after washing and cleaning thoroughly. 104 periodical cleaning of sewage well as capacity ( upto 5mtrs dia and 9 mtrs depth ) cum and removing of settle down sewage sludge cum mud / de silting etc. all as required at site anddirected atanand parbat mil stn ( klp location, map ph i ) and cod area. note: the rate quoated by the tenderer is deemed to be included in the unit rate of the following : 105 diesel driven pump set of appropriate capacity not less than 5 / 7.5 hp with operatorincluding necessary pol required at site for de watering of sewage septic water including pvc heavy duty flexible hose pipe for suction and delivery purposes 106 tractor mountedstorage tank of appropriate capacity not less than 1 kl with driver directly collected from the soak well and disposing the same to the location out side of military contonement where as approved by pcb and also liase with delhi muncipal corporation board as directed. 107 tractor / truck with driver for disposal of sewage sludge and pol required for the same ( duly covered with necessary tarpaline ) and depositing the same to the location where approved by pcb or as directed.. 108 labour element and t&p required for removal of settled down sewage sludge / mud inside the sewage tank for scooping out from inside and below the septic / staining sewage water inside the well and lifting the same and deposited out side of military contonment and out side location as mentioned above. 109 appropriate qty of phenyle required at site for sterilization of sewage sludge being collected in the sewage tank and all as directed. 110 necessary oxygen mask, gloves, gum boot and all other safety aspects and including necessary phawda, steel bucket, manila rope etc. required at site and all as directed. 111 m&l for cleaning oftreated water tank atanand parbat at klp loaction stp of storage capacity of water 50000 gallons, filter feed tank of capacity 63 cum and chlorine contact tank of capacity 17 cum thoroughly by removing mud, grits etc from the tankby following method : 112 cleaning inner surface of tank complete by scraping with steel wire brush and and removing mud and sludge collected inside the tank manuallyat a distance not exceeding 50 mtr all as directed. 113 washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed. 114 supply and laying including taking up galvanised steel water tubing medium grade isi marked screwed socketed joints complete with all tube fitting ( such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, threaded flanges and unions, etc ) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also cutting, screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes: 115 80 mm dia 116 50 mm dia 117 40 mm dia 118 supply and laying mild steel water tubing heavy duty with welded joints complete with all tube fitting ( such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, flanges and unions, etc ) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also cutting, screwing, welding and waste end for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes: 119 40 mm dia 120 50 mm dia 121 80 mm dia 122 100 mm dia 123 supply and fixingbutterfly valves iron body screwed down high pressure with iron wheel head / long shank and cup butterfly type screwed both ends for iron pipe including taking out unserviceable valve for the following sizes: 124 40 mm dia 125 50 mm dia 126 80 mm dia 127 m&l for spray painting two coats of synthetic enameled paint of specified colour after preparation of surface and writing letters and numbers complete of complete sewage treatment plant capacity 100 cum / day with equalization tank, raw sewage pumps, mbbr reactor, chlorine tank, filter feed pump, dual media filters, rcc treated water tank, treated filter pumps, sludge drying beds, oil free blowers and accessories complete all as specified and directed. 128 m&l for disconnection electrical and water connection of the monoblock pumpset with motor and base plate and transporting to work shop opening carefully and replacement of winding, bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size / capacity of motors upto7.5 hp.note : rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning. 129 m&l for disconnection electrical and water connection of the compressors and transporting to work shop opening carefully and replacement of spare parts bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size / capacity of up to 110 m3 / hr.note : rate includes transportation of compressor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning. 130 m&l for lifting / lowering of non clogging submersible pump and motor capacity up to 7.5 hpfrom sewage well after disconnecting electric and water connection of any make and any size capacity under any of chain pulley block or manually appropriate length upto 10m after opening the socket and pipe eplacement of winding, bushes, gland packing, ball bearing, thrust bearings, sand guard plate, gm impellers, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed. 131 supply and fixing in reapirs of multi port valvesfixing at mediafilter vesselses for stpall as specified and directed. makes as per sample. 132 s&f in repairs for dosing unit capacity electronic metering pumps for chemiclas dosing system for stp incl inlet and outlet flexible pvc pipes all as specified and directed.makes as per sample 133 material & labour in repairs for cross arms, bracings, supports, clamps, angle iron, flats, ladders and back plates fabricated from ms structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending ( cold or hot ) , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as directed. 134 m&l for diamantling, opening of automatic voltage stabilizer 200 kva rating ( 300 480 volts ) , out put 415 v including disconnecting electric connectioncomplete all as specified & directed. 135 m&l for repairs taking up deemer assembly complete by carefully by manual chain pulley block and replaceemnt of burnt wiinding coil with existingsize and gauge of copper winding wire inclduing transportation charges from site to work shop and back complete all as specified & directed. 136 m&l for replacment of motor assembly for moving of 20 kg load complete all as specified & directed. 137 m&l for replacement of carbon brush ( 03 sets of 03 nos each ) complete all as specified & directed. 138 m&l for repair of internal wiring and servicing complete all as specified & directed. 139 m&l for in repairs machine pressed precast conctete interlocking paver block with grey cement and no pigment any shape and size confirming to is 15658 2006 of 60mm thickness, m 35 grade including sand filling including dismantling complete all as specified and directed. 140 demolition of pcc in ground floor and paving not exceeding 15 cm thickness ( below or above ground level ) complete all as specified & directed. 141 m&l for broken stone boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, wateredand rammed to a true surface including demolition complete all as specified and directed. 142 m&l for sand filling under floors or in foundations including watering and consolidation complete all as specified & directed. 143 shifting and relocating of trolley mounted transformer of any capacity and ratingin aor ( i.e. kwc camp mrs area toanand parbat mil stn mrs area ) outdoor type including removing and refixingnecessary cable connections complete all as specified and directed. note: ( i ) necesary t&p complete shall be arranged by the contractor. ( ii ) during shifting process damage to any existing infrastructure, the same is make good by his own cost. 144 taking up existing di pipe sewage water pumping system line 80 to 150mm bore including fittings and relaying, jointing and testing of same in to trenches in position after cleaning and removal of scale / blockage complete for the following sizes note earth work, lead joint and rubber tyton joints shall be measured and paid separately under relevant items : 145 material and labour for di specials of any size such as tees, bends of any sizeand radius, tapers, collers, tail pieces, caps and plugs etc incl takinng down unsv complete all as specified. 146 m&l for rubber gasket joint ( tyton joint ) with jointingmaterial for di pipe of 80 to 150mm bore including taking down unserviceable complete all as specified and directed. 147 material & labour for earthing with galvanised steel earth plate electrode 60cmx 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usinggalvanised iron strip of size 32 x 6 mm as earthing lead ( upto the body ofthe equipment ) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm diagi pipe connected to main switch board or main control board and gi pipe medium grade 20mm bore for watering and including funnel , wire mesh , rcc pit cover and pcc chamber pit with pcc ( 1:3:6 ) type c 2 using 40mm graded crushed stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate no 5 ofssr 1991 ( part i ) including testing on completion if desired earth resistance is not obtained the earthing will be redone without extra cost complete all as specified anddirected. 148 s&f earth continuity conuctor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit / pipe or fixed to the pole or any other situation for loop earthing etc as required32x6 mm dia galvanised iron strip all as per specified and directed....

Public Works Department - Delhi

33633620 repair maintenance of of e and m services installed at 200 bedded jpc hospital, shastri park, delhi 110053. sub head open auction in respect of dismantled material of electrical and mechanical accessories under sub division ae ( e ) he ii, pwd, lbsh rmo of e and m services installed at 200 bedded jpc hospital, shastri park, delhi 110053. sub head open auction in respect of dismantled material of electrical and mechanical accessories under sub division ae ( e ) he ii, pwd, lbsh , 1 ball bearing 6201 / 6202 assorted2222 nos. 2 gi pipe assorted9 p / mtr 3 submersible flat wire assorted80 p / mtr 4 pole box assorted95 nos. 5 5 / 6 a switch / socket assorted3604 nos. 6 tp / tpn mcb assorted330 nos. 7 phenolic sheet assorted23 nos. 8 4 pole isolator assorted105 nos. 9 tube starter assorted558 nos. 10 lead acid battery assorted2 nos. 11 starting / running capacitor assorted233 nos. 12 tpdb assorted8 nos. 13 assorted tube holder assorted570 nos. 14 assorted ignitor / condenser430 nos. 15 assorted lamp ends232 nos. 16 f1, tube ends assorted204 nos. 17 assorted sp / dp mcb 1244 nos. 18 assorted copper chock 28 watt 120 nos. 19 assorted copperchock 40 watt 120 nos. 20 assorted copper chock 70 watt 114 nos. 21 assorted copper chock 150 watt 64 nos. 22 assorted copper chock 250watt 60 nos. 23 assorted old ceiling fan ( without blade ) 1031 nos. 24 9 / 11 watt chock assorted. 185 nos. 25 15 amp socket p / t assorted 661 nos. 26 assorted fan blades ( single piece ) 1439 nos. 27 assorted tube fittings ( 1x20 / 1x36 / 1x40 / 2x36 ) watt 1317 nos. 28 condensor 2.5 mfd assorted 2730 nos. 29 regulator ( resistance type ) assorted 41 nos. , 30 tp mccb 400 a / 200 a assorted16 nos. 31 tp mccb 250 a assorted11 nos. 32 wall mounted fan 16 assorted 91 nos. 33 1x28 watt / 2x28 / 1x36 / 2x36 / 4x14 / 1x14 / 4x14 watt electronic ballast1573 nos. 34 1.5 sq. mm pvc insulated al wire assoreted 73.1 kg 35 brass batten holder 74 nos. 36 250 watt hpsv lamp cap 80 nos. 37 dol starter assorted 7 nos. 38 4 mfd capacitor 15 nos. 39 tp mccb 100 a 10 ka 52 nos. 40 400 watt mh / hpsv ballast12 nos. 41 flood light fittings assorted 150 / 250 watt 34 nos. 42 2x16 sq. mm pvc cable 50 mtr 43 submersible pump set assorted ( 3 / 5hp ) 3 nos. 44 portable sewage pump set assorted ( 1hp ) 2 nos. 45 assorted 3 pin plug 16a 333 nos. 46 assorted exhaust fan 380 / 300 mm 32 nos. 47 fan regulator ( modular type ) assorted 107 nos. 48 assorted split type ac ( indoor & outdoor ) units 3 nos. 49 assorted split type ac ( indoor only ) 1.5tr units 1 no. 50 assorted wtac ( 1.5 tr ) 8 nos. 51 assorted wtac ( 2.0 tr ) 1 nos. 52 assorted water cooler ( with compressor ) 6 nos. 53 assorted switch 5 / 6 a piano type 341 nos. 54 assorted water cooler ( without compressor ) 5 nos. 55 assorted 16 a ( 1 m ) switch 1240 nos. 56 assorted 6 16 a 6 pin socket ( 2m ) 932 nos. 57 assorted 7.5 hp sewage submersible pump 4 nos. 58 assorted module plate ( 3 m / 6m / 12m ) 190 nos. , 59 assorted 1.5 sq.mm / 2.5 sq. mm / 4 sq. mm al wire ) 906 mtr 60 assorted 6 / 10 sq.mmal wire ) 537 mtr 61 assorted type al. 407 kg 62 assorted al. lugs ( 70 / 95 / 150 / 240 / 40 sq. mm ) 55 nos. 63 rusted type y strainer 150 mm 4 nos. 64 assorted type ( 4x14 watt / 3x14 watt / 2x14 watt ) tube fitting 400 nos. 65 assorted type ( 1x1 ) fitting ( 28 watt / 36watt ) 1107 nos. 66 dismentled led 1x4 48 wat led fittings 47 nos. 67 assorted emergency light 10 nos. 68 assorted size empty fire cylinder ( 4.5 kg / 6 kg / 9kg ) 145 nos. 69 assorted burnt winding wire 41.5 p / kg 70 assorted gate valve 80 mm 1 no. 71 assorted gate valve 100 mm 1 no. 72 assorted power contractor ml 1.5 6 nos. 73 assorted 14 watt chock 12 nos. 74 assorted ct ( for fly trapper ) 11 nos. 75 assorted 1.5 sq. mm pvc cable 169 kg 76 assorted butter fly valve 7 nos. 77 assorted ms pipe 150 mm 5 mtr 78 assortedsyphon 20 nos. 79 assorted pressure guage 66 nos. 80 assorted al. alloy blade 3 nos. 81 assorted 50 mm dia gate valve 4 nos. 82 assorted element lub oil filter 8 nos. 83 assorted 5 hp submersible pump 10 nos. 84 assorted oil cleaner 2 nos. 85 assorted lub oil filter 2 nos. 86 assorted kit fuel filter 2 nos. 87 assorted kit super bypass filter 1 no. , 88 assorted discharge head 5 nos. 89 assorted piston housing set 5 nos. 90 assorted piston5 nos. 91 assorted suction filter 4 nos. 92 assorted oil filter 1 no. 93 assorted esd controller 1 no. 94 assorted drier core 3 nos. 95 assorted filter element 2 nos. 96 assorted 70 watt bulb 11 nos. 97 assorted 250 watt bulb 1 no. 98 assorted 2x11 watt fitting 63 nos. 99 assorted 28 watt fitting 894 nos. 100 assorted 9 watt bulkhead 137 nos. 101 assorted mcb 270 nos. 102 assorted 4way db 413 nos. 103 assorted dp 111 nos. 104 assorted radiator 1 no. 105 assorted 3x14 watt fitting / 4x14 watt fitting 114 nos. 106 assorted 250 watt chock 37 nos. 107 assorted tubular 48 nos. 108 assorted steam valve bronze 4 nos. 109 assorted filter oil 2 nos. 110 assorted oil pressure pump 2 nos. 111 assorted oil pipe set 2 set 112 113 assorted fire control panel 2 nos. 114 assorted overload relay 1 no. 115 assorted single phase preventor 1 no. 116 assorted feeder pillar 2 nos. , 117 assorted voltmeter 3 nos. 118 assorted ammeter 9 nos. 119 assorted 8 way db 24 nos. 120 assorted 12 way db 8 nos. 121 assorted contacts 25 nos. 122 assorted 2x 28 watt fittings 3 nos. 123 assorted led light 5 nos. 124 assorted power pack 1 nos. 125 assorted 1x1 led fitting 48 nos. 126 assorted hpsv fitting ( 70w / 150w / 250w ) 76 nos. 127 assorted condenser line 6dia 6 mtr 128 assorted aviation light 2 nos. 129 assorted timer 1 no. 130 assorted pre filter 62 nos. 131 assorted 1.5 tr fcu 11 nos. 132 assorted 2tr fcu 2 nos. 133 assorted filter capsule ( fibre body ) 2 set 134 assorted frequency meter 2 nos. 135 assorted kwh meter 2 nos. 136 assorted pf meter 2 nos. 137 assorted wall fan 22 nos. 138 assortedductable ac 2 nos. 139 assorted 3hp pump 3 nos. 140 assorted copper pipe 23 mtr 141 assorted gyeser ( 50 ltr ) 11 nos. 142 assorted selector switch 5 nos. 143 assorted change over switch 63 a 2 nos. 144 assorted tsf fuse 2 nos. 145 assorted voltage relay 13 nos. , 146 assorted capacitor 3 phase 100 nos. 147 assorted fuse 16 nos. 148 assorted fuel filter 1 no. 149 assorted indicator led 3 set 150 assorted louvers 200 nos. 151 assorted db 6 way 34 nos. 152 assorted 2x2 led fitting 14 nos. 153 assorted motherboard ( led signage ) 23 nos. 154 assorted pcb ( singage ) 48 nos. 155 assorted 7 in 1 meter 4 nos. 156 assorted single / three phase statc switch module 15 nos. 157 assorted butterfly valve 150 mm 21 nos. 158 assorted butterfly valve 125 mm 5 nos. 159 assorted balancing valve 125 mm 5 nos. 160 assorted 70 watt post top lantrn 30 nos. 161 assorted rotary switch 2 nos. 162 assorted time relay 4 nos. 163 assorted 3 / 4 / 6 module box 60 nos. 164 assorted contractor 18 nos. 165 assorted 400 watt lamp 6 nos. 166 assorted fly trapper transformer 10 nos. 167 assorted fly trapper ballast 10 nos. 168 assorted hose cabinet 11 nos. 169 assorted landing valve 8 nos. 170 assorted butterfly valve ( 80 mm ) 3 nos. 171 assorted smoke detector 40 nos. 172 assorted 7.5 hp, 3 phase submersible pump 2 nos. 173 assorted 3 hp, 1 phase submersible pump 5 nos. 174 assorted 1.5 hp, submersible pump 1 no. , 175 assorted ama porter 1.1 kw 1 nos. 176 assorted compressor 1.5 / 5tr 21 nos. 177 assorted discharge assembly 2 nos. 178 assorted rolling shutter 2 nos. 179 assorted butterfly valve 100 mm 3 nos. 180 assorted 32 a switch 1 no. 181 assorted monoblock pump 3 hp 2 nos. 182 assorted 1650 va inverter 1 no. 183 assorted sluice valve 3 nos. 184 assorted on load change over switch 1250a 1 no. 185 assorted sluice valve 150 mm 3 nos. 186 assorted sluice valve 80 mm 2 nos. 187 assorted desert fan kit 6 nos. 188 assorted sluice valve strainer 150 / 125 mm dia 8 nos. 189 rusted ahu i / c blower & motor assembly 2 nos. 190 assorted balancing / butterfly valve 40 mm 10 nos. 191 assorted 1.5 / 2 tr condeser, coolingcoil 10 nos. 192 assorted voltage stabilizer 5 nos. 193 assorted db box 2 nos. 194 assorted water flow switch 2 nos. 195 assorted air diffuser 43 nos. 196 rusted 40 mm ms pipe 60 mtr 197 assorted nrv 150 mm dia 2 nos....

Military Engineer Services - Delhi

33380437 repair / maintenance of summer appliances window type / split type / cassatte type acs and allied services at kashmir house under ge new delhi 1 labour for checking and attending complaints of acs, refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed. ( any parts required forreplacementshall be measured and paid separately under respective items ) notes: ( a ) the contractor should detail minimum one ac mechanic & one helper to attend complaints in kashmir house . ( b ) the complaint should be attended on same day with in 3 hours . ( c ) ) if the complaint not attended / not completed on same daywith in three hours recovery will be done as follows: ( i ) for first day rs.1000 / ( ii ) for second day rs.1500 / ( iii ) for nextevery day rs.2000 / 2 servicing of window type ac 1.5 / 2 ton capacity ofany make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checkingof electric circuit for smooth functioning of ac 3 all as per item no 2 above but split type ac of any type and 1.5 / 2 ton capacity 4 servicing of three phase cassette / tower type split ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified. note: unserviceable spares parts required to be replaced shall be measured and paid separately under respective items. 5 supply only against repairs running capacitor combination ( 50 mfd + 6 ) / ( 50+4 ) mfd 230 voltfor ac upto 4.00 ton . 6 supply only in replacementrunning capacitor 6 mfd 230 volt 7 supply only in replacementrunning capacitor 4 mfd 230 volt 8 supply & charging gas refrigerant r 22 / 410 a / or as existing to window type / split type / cassette / package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer in charge 9 supply onlyin replacementstarting relay suitable for 1.5 / 2 ton capacity ac 10 supply onlyin replacementover load protector suitable for 1.5 ton capacity ac 11 supply onlyin replacement thermostat switch suitable for 1.5 / 2 ton capacity ac 12 supply only against in repair item ofstarting relay suitable for 4.0 ton capacity ac complete all as specified. 13 supply only against in repair item ofover load protector suitable for 4.0 ton capacity ac complete all as specified. 14 supply only against in repair item ofthermostat switch suitable for 4.0 ton capacity ac complete all as specified. 15 supply and fixingin replacementreciprocating / rotary type compressor suitable for 1.5 to 2.0ton capacity split type ac of the same make and model as per existing make of acs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed. 16 supply and fixingin replacementreciprocating / rotarytype compressor suitable for 1.5 to 2 ton capacitywindow type ac of thesame make and model as per existing make of acs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed. 17 supply and fixingin replacementany type of compressor suitable for inverter type 1.5 to 2 ton capacitysplitac of thesame make and model as per existing make of acs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed. 18 supply and fixingin replacement ofthree phase compressor suitable for 3.5 to 4.0 ton capacity suitable of cassette / tower acof the same make and model as per existing make of acs complete all as specified and directed. 19 supply onlyin replacement wiring kit suitable for 1.5 / 2 ton capacity ac complete all as specified & directed 20 supply only in replacement air filter synthetic / nylon as per existing size and shape suitable for 1.5 / 2 ton capacity window type acs 21 supply only in replacement air filter synthetic / nylon as per existing size and shape suitable for 1.5 / 2 ton capacity split type acs 22 supply only against in repair item ofair filter synthetic / nylon type as per existing size and shape suitable for 3.5 / 4.0 ton capacity cassette type split acs complete all as specified. 23 supply only in replacement new fan motor ( indoor / outdoor ) 1 / 4, 1 / 5 hp single / double shaft as per existing model suitable for splittype acs 1.5 / 2 ton complete all as specified and directed. 24 supply only in replacementnew dc fan motor ( indoor / outdoor ) 1 / 4, 1 / 5 hp single / double shaftas per existing model suitable for splittype acs 1.5 / 2 ton complete all as specified and directed. 25 supply only against in repairoffan motor single / double shaft as per existing model suitable for 3.5 / 4.0 ton acs of any make / type complete as per requirement on site all as specified. 26 supply only against in ofnew dcfan motor single / double shaft as per existing model suitable for 3.5 / 4.0 ton cassette typeacs of any make / type complete as per requirement on site all as specified. 27 m & lfor rewinding of fan motor suitable for acs up to 4 ton capacity with super enamelled copper winding wire of same gauge including replacement of insulating material, bushes and shaft all as specified & directed 28 supply onlyin replacement pvc insulatedflexible copper conductor 3 core 1100v grade of size 2.5 sqmm. 29 supply onlyin replacement pvc insulatedflexible copper conductor 3 core 1100v grade of size 4.0 sqmm. 30 supply onlyin replacementcondenser fan blade made out ofplastic suitable for upto 2 ton capacity window type acs. 31 supply onlyin replacementcondenser fan blade made out ofplastic suitable for upto 2 ton capacity split type acs. 32 supply only against in repairofcondenser fan blade made out of aluminium suitable for upto 4.0 ton capacity cassette type split acs complete all as specified & directed. 33 supply onlyin replacement of evaporatingair blower made out ofsuitable for upto 2 ton capacity for window type ac all as specified and directed 34 supply onlyin replacement of evaporatingair blower made out of suitable for upto 2 ton capacity for split type ac all as specified and directed 35 supply only against in repairofindoor air blower made out ofsuitable for upto 4.0 ton capacitytype split acs complete all as specified & directed. 36 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 6.0 mm ( 1 / 4 ) for refrigerant copper piping of split ac units. 37 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 13.0 mm ( 1 / 2 ) for refrigerant copper piping of split ac units. 38 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 9 mm ( 3 / 8 ) for refrigerant copper piping of split ac units.make: supreme / gulf o flex / superlon. 39 supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter 16 mm ( 5 / 8 ) for refrigerant copper piping of split ac units.make: supreme / gulf o flex / superlon. 40 m & l for replacement of front grill suitable for window type acs upto 2 ton capacity of any make as per existing size and shape. 41 m & l for replacement of reverse valve system suitable to 1.5 / 2 ton split / window ac for heating option. ( gas charging shall be paid and measured under respective item ) 42 supply onlycopper tubing heavy duty inner dia 6 mm ( 1 / 4 ) for refrigerant for acs. make mandev / mandley / uniflow 43 supply onlycopper tubing heavy duty inner dia 13mm ( 1 / 2 ) for refrigerant for acs. 44 supply onlycopper tubing heavy duty inner dia 9 mm ( 3 / 8 ) for refrigerant for acs. 45 supply onlycopper tubing heavy duty inner dia 16 mm ( 5 / 8 ) for refrigerant for acs. 46 supply onlycondensing coil suitable for 1.5 / 2 ton splittype acs as per existing size / shape and as per existing make. 47 supply onlyevaporating coil suitable for 1.5 / 2 ton splittype acs as per existing size / shape and as per existing make. 48 supply onlybrass flare nut / connector heavy duty of size 6 mm / 9 mm ( 1 / 4, 1 / 2 ) as per existing make. 49 repair to control processing board ( remote control kit ) with hand set including replacement of current transformer, ics, diodes, resistances, sensors etc complete for 1.5 / 2 ton split type acs of any make & model. 50 repair to control processing board ( remote control kit ) inverter typewith hand set including replacement of current transformer, ics, diodes, resistances, sensors etc complete for 3.5 / 4 ton split type acs of any make & model. 51 supply and fixingin replacement split type ac 1.5 / 2 tonindoorunit kitwithpcb complete withsensor complete with fixing plate suitable to non inverter type ac complete all as specified and directed. 52 supply and fixingin replacement split type ac 1.5 / 2 tonindoorpcb unit kitcomplete withsensor complete with fixing plate suitable to inverter typemodel and make ac all as specified and directed. 53 supply and fixingin replacement split type ac 1.5 / 2 ton outdoor unit kit complete with compressor, condensor coil, condenser fan with blade and sensor suitable to non inverter typeexisting model and make ac all as specified and directed. 54 supply and fixingin replacement split type ac 1.5 / 2 ton outdoor unit kit complete with compressor, condenser coil, condenser fan with blade and sensor suitable toinverter typeexisting model and make ac all as specified and directed.make: carrier / blue star / napolean / totaline. 55 supply and fixingin replacement window ac kit 1.5 / 2 tonpcbwith sensorcomplete with condensing coil, fan motor, blower and motor, compressor and grill complete suitable to non inverter type existing model and make ac all as specified and directed.make: carrier / napolean / skoda. 56 supply only in replacementair direction changer louver motor ( swing motor ) suitable for split type acs as per existing make and model 57 supply only in replacement cordless remote for inverter type acshot & cool suitable for 1.5 ton ac as per sample. 58 supply onlyin replacement cordless remote for acssuitable for 1.5 / 2 tonsplit / windowac as per sample. 59 servicing of refrigerators of 165 to 310 ltrcapacitysingle door ofany make / model by cleaning of condensing coil with wire & brush to remove dust includingcheckingof electric circuit for smooth functioning complete all as specified and directed by engr in charge 60 supply and fixingin replacementnew compressor suitable for 165 / 310ltr capacity refrigerator reciprocating type complete all as specified and directed. 61 supply and fixingof monkey menace protection device with pvc spikes size as per sample all as specified and directed 62 taking down ac of any type, any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repairwork, transportation back to location of installation , reinstallation / refixing in position after complete repairs as required and making functional includingtesting complete all as specified and directed. 63 supply and fix of drain pipe of any size suitable for split ac of capacity 1.5 / 2 / 3.5 / 4 tr as per sample all as specified and directed 64 m&l in replacement metalclad plug & socket board sp&n enclosure with single pole and earth metal plug & socket suitable for 20 amps mcb ac, 220 v, 50hz . 65 m&l in replacement modular acboard sp&n enclosure with single pole and earth metal plug & socket suitable for 20 amps mcb ac, 220 v, 50hz 66 supply, installing, testing and commissioning in replacement factory made and tested outdoor type, platform mounted, phase sequence corrector of capacity 63 a , 3 phase 4 wire, 415 volts, 50 hz, platform mounted. the phase sequence corrector shall be dust and vermin proof, protection class ( ip 54 ) and made of 2.00 mm thick stainless steel sheet 316l thick & suitable frame work / support made out of 75 mm stainless steel flat channel, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with pvc insulated multistranded copper conductor frls cable of adequate size but not less than 1.5 sqmm complete. the scope of work also comprising of the following: make: havells / schneider / abb / l&t / universal switch gear control. note work includes civil work like excavation and preparation of pcc plinth 67 phase sequence corrector of capacity 63 a , 3 phase 4 wire, 415 volts, 50 hz with facility to change over from automatic to manual, microprocessor release ( over load, short circuit, instantaneous single phasing, phase reversal ) , pre trip alarm and individual fault indication led with fully rated neutral with inbuilt protection. the over load release shall be adjustable type, protection: avoid damages during phase sequence changes or reversal.• the sequence corrector will switch off, during the single phasing or imbalance voltage occur & later, auto reset after restoration.• no break downs of three phase system due to the change in sequence.• bye pass selector switch in case of controller faulty. 68 the panel manufacturer should have following govt. approved certificates: 1. cpri certification degree of protection ip 542. cpri certification short circuit withstand strength should be 50karms for 1.0 sec with initial peak of 105ka 3. cpri certification rated current for short circuit not less than 4000a with rated insulation voltage 660v4. iso 9001 certified 69 supply, install, commissioning and testing in replacement of lt panel board outdoor type floor mounted of factory made powder coated made out of outside body of 2.00 mm thick stainless steel sheet 316l thick & suitable frame work / support made out of 75 mm stainless steel flat channel, , locking arrangement, front side and rear side opening arrangement of suitable size, incl mounting onduly grouting or welded on floor. aluminium bus bar tpn of 600 a for mccb to all feeders to accommodate following items: ( a ) incoming mccb 250 amp 50 ka 4 pole, microprocessor based energy release 01 no cat no hmt250nr hageurs, equivalent in legrand / schneider ( b ) outgoing mccb 100 amp 40 ka 3pole, microprocessor based energy release 04 no hns100 nr ( c ) ryb indication for each incoming & outgoing supplies 01 set ( d ) voltmeter, amp meter, digital type with ct’s &selector switch 01 set ( e ) termination of all cables with suitable size thimble and gland 1job ( f ) termination of all cables with suitable size thimble and gland 1 job . make for ss enclosure : havells / schneider / abb / l&t / universal switch gear control. note work includes civil work like excavation and preparation of pcc plinth 70 supply, install, commissioning and testing in replacement of lt panel board indoor type floor mounted of factory made powder coated made out of outside body of 2.00 mm thick stainless steel sheet 316l thick & suitable frame work / support made out of 75 mm stainless steel flat channel, locking arrangement, front side and rear side opening arrangement of suitable size, incl mounting onduly grouted or welded on floor. aluminium bus bar tpn of 600 a for mccb to all feeders to accommodate following items: ( a ) incoming mccb 200 amp 50 ka 4 pole, microprocessor based energy release 01 no.cat no hmt250nr haguer, equivalent in legrand / schneider ( b ) outgoing mccb 100 amp 40 ka 3pole 04 no microprocessor based energy release 01 no.cat no hns100nr hager, equivalent in legrand / schneider ( c ) changeover on load for open execution 200 amp ( d ) ryb indication for each incoming & outgoing supplies 01 set ( e ) voltmeter, amp meter, digital type with ct’s &selector switch 01 set ( f ) termination of all cables with suitable size thimble and gland 1job ( g ) termination of all cables with suitable size thimble and gland 1 job . make for ss enclosure : havells / schneider / abb / l&t / universal switch gear control . note work includes civil work like excavation and preparation of pcc plinth 71 supply only in replacement voltage stabilizer of capacity 3 to 5 kva , copper wounded made of metallic steel body complete all as specified and directed 72 s&f in replacement of plug top3 pin, 15 amps, 230 volts, 50 hz ac complete all as specified. 73 m&l for taking down split / window ac and shifting from one position to other within the premises complete with copper tubing indoor plate and copper tubing complete with all accessories with making good the disturbed surfaces with cement plaster and pop . complete all as specified and as directed by engr in charge 74 s&f sub main wiring in replacement with two runs pvc insulated unsheathed frls stranded copper conductor cable of size4.0 sqmm along with one run of pvc insulated unsheathed stranded copper conductor cable of size 2.5 sqmm as earth wire connected to earth dollyfixed on surface of wall / ceiling / in concealed pvcconduits complete including cutting chases and making good to walls at disturbed area all as specified and directed. make of conduit plaza / kalingamake of cable rr kabel / havells / polycabnote : two run of 4.0 sqmm copper conductor cable, one run of 2.5 sqmm copper cable and one run of pvc conduit shall be measured as one unit length 75 all as per item no 74 here in before but size of cable 2 x6sqmmcomplete along with cable 1x2.5 sqmm frls type for continuous earth wire and connected to common earth dolly complete all as specified.make rr / havells / polycabnote : two run of4 sqmm copper conductor cable, one run of 2.5 sqmm copper cable and one run of pvc conduit shall be measured as one unit length 76 supply only in replacement of factory made load line dbs double door made out of crca mild steel sheet with insulating materials like polyester epoxy coated surface mounting 12 way tpn 415 volts, ip 43 with suitable busbar, neutral link & earth link suitable for mccb tp as incomer & mcb sp / tp as out going complete all as specified 77 supply only in replacement of factory made load line dbs double door made out of crca mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way tpn 415 volts, ip 43 with suitable busbar, neutral link & earth link suitable for mccb tp as incomer & mcb sp / tp as out going complete all as specified. 78 supply only in replacement of mccb tp / tpn125 amp, 25ka thermal type complete all as specified. 79 supply only in replacement of mccb tp / tpn 160 amp, 25ka thermal type complete all as specified. 80 supply only in replacement of mcb sp 40 63 amp, 10ka all as specified. 81 supply & fixed rigid non metallic 20 mm external dia pvc conduit concealed on surface to wall / ceiling for drain out of water from split type and window typebut inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks up to outdoor unit to ground floor level all directed by engr in charge. 82 supply only in replacement flexible pipe 15 / 20 / 25 mm dia white colour complete all as specified and directed 83 supply only in replacement of mcb spn 20 32 amp, 10ka all as specified. 84 m & l for making suitable hole in the wall to fix window or split ac and maintain the surface as per existing note : ( a ) plastering , putty , painting included in the quoted rate . ( b ) covering the window by ply if necessary also included in the quoted rate 85 supply only in replacement wall stand / chauki stand to fix outdoor of split / cassette ac made ofmetallic stell complete all as specified and directed 86 supply only in replacement fastener upto 8mm size suitable to fix wall stand / chauki stand complete all as specified and directed...

Northern Railway - Delhi

32759466 supply of dual coat super enamelled copper winding wire of size 18 swg confirming to is:13730 part xiii grade 2.dual coat super enamelled copper winding wire of size 18 swg confirming to is:13730 part xiii grade 2.,dual coat super enamelled copper winding wire of size 18 swg confirming to is:13730 part xiii grade 2. dy.chief material haryana 200.00 kg manager/judw , nr...

Public Works Department - Delhi

32484238 repair maintenance of e and m various services installed at rgss hospital at tahirpur, delhi sub head repairing of wetriser system and replacement of wornout components providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 3589 / is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 2 80 mm dia 3 100 mm dia 4 150 mm dia 5 200 mm dia 6 250 mm dia 7 300 mm dia 8 providing laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239 / 3589 i / c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar / asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. 9 150 mm. dia 10 supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with ronze / gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required : 11 80 mm dia 12 100 mm dia 13 150 mm dia 14 200 mm dia 15 providing, installation, testing and commissioning of non return valve of following sizes confirming to is:5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required : 16 80 mm dia 17 100mm dia 18 150 mm dia 19 supplying and fixing single headed internal hydrant valve with instantaneous gunmetal / stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 ( type a ) with blank gunmetal / stainless steel cap and chain as required : 20 single headed stainless steel 21 supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm dia instantaneous fm gunmetal / stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 ( type a ) with blank gunmetal / stainless steel cap and chain as required : 22 single headed stainless steel 23 supplying and fixing first aid hose reel with ms construction spray painted in post office red, conforming to is 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic ( textile reinforced ) type 2 as per is: 1258520 mm nominal internal dia gun metal globe valve & nozzle.drum and brackets for fixing the equipments on wall. connections from riser with 25 mm dia stop gun metal valve & m.s. pipe and socket. 24 30 mm 25 supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 26 providing & fixing of pressure switch in m.s. pipe line including connection etc. as required. 27 supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia ms pipe connection conforming to is 904 as required 28 3 way 150 mm dia m.s. pipe 29 providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. 30 dismantling, rewinding, servicing and refixing of 75 hp capacity main pump set with copper winding wire i / c varnishing, baking, f class insulation paper, glass sleev, white cotton tape & solder wire, paste, old dhoti etc. i / c testing commissioning etc as required. 31 repairing / replacement of worn out parts i / c mechanical seal & servicing of diesel driven horizontal type multistage, centrifugal, split casing / main pump with bronze impeller stainless steel shaft, mechanical seal of 75 / 85 hp diesel driven horizontal type multistage, centrifugal, split casing / main pump i / c dismantling & credit old dismantled material. a ) mechanical seal upper & lower – 2 setb ) new bearing 2 nos. – 2 setc ) tpn ( tripping switch ) – 2 nos.d ) nut bolts, glow tube – 2 sete ) cable binder – 2 setf ) end cable bush – 2 setg ) o ring set & gasket set 2 set 32 painting with synthetic enamel paint of approved brand & manufacture to give an even shade: a ) two or more coats on new work. 33 supplying & fixing of weather proof hose cabinet of size 900mmx600mmx500mm suitable for external yard hydrant / fbic fabricated ( 16 gauge suitable for 2 no. 15mtr. hose and 1 no. short branch pipe and 1 no. hydrant ) out of 1.6 mm thick ms sheet with 4 mm thick glazed glass door in front having locking arrangements, suitable to accommodate external / internal hydrant with valve, hose reels, branch pipe / fbic etc. mounted on wall or raised plateform and duly painted with po red externally & white internally with synthetic enamel paint etc. complete in all respects as required. 34 supplying and laying of aluminium conductor pvc insulated and pvc sheathed / xlpe armoured power cable, 1.1 kv grade of following size and manner etc as required 35 3x35 sqmm cable on wall surface as required 36 3x95 sqmm cable on wall surface as required 37 dismantling, rewinding, servicing and refixing of 7.5 hp capacity main pump set with copper winding wire i / c varnishing, baking, f class insulation paper, glass sleeve, white cotton tape & solder wire, paste, old dhoti etc. i / c testing commissioning etc as required. 38 servicing, overhauling and refixing of 7.5 hp capacity main pump set with copper winding wirei / c varnishing, baking, f class insulation paper, glass sleeve, white cotton tape & solder wire, paste, old dhoti etc. i / c testing commissioning etc as required. 39 less credit dismantle item such as ms pipe, butterfly valve, nrv, hydrant, pressure gauge, air vassal, hose cabinet, cable etc...

Department Of Defence - Delhi

32136166 bids are invited for as per appdx ser no 1 total quantity : 1 maintenance and replacement of spares / parts of vrv air conditioning system cap 82.5 tr installed at vvip receptorium tech area af stn palam ( a ) replacement of shaft seal assembly suitable for existing compressor incl leak test by falling nitrogen gas and vaccum the system with pump complete. job 2. complete one job ( b ) supply and fixing hp / lp cutout assembly make : danfoss. nos 3. ( c ) m & l for rewinding of indoor unit electric motor cap 7.5 hp with super enemelled copper winding wire of existing gauge incl replacement of necessary ball bearing complete. job 1 ( d ) replacement of microprocessor printed circuit board of ac plant incl adjusting & updating with software configuration make: daikin. nos 2 ( e ) supply and fixing refrigerant gas r – 410 make: metron. kg 44. ( f ) replacement of power protection relay suitable for 82.5 tr vrv system make: daikin. nos 1...

Northern Railway - Delhi

32032177 supply of dual coat round copper winding wire size 21swgdual coat round copper winding wire size 21swg,dual coat round copper winding wire size 21swg [0.813mm]nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s....

Northern Railway - Delhi

30910469 supply of dual coat round copper winding wire size 19 swg [1.0160mm] nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s.dual coat round copper winding wire size 19 swg [1.0160mm] nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s.,dual coat round copper winding wire size 19 swg [1.0160mm] nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s....

Indian Army - Delhi

30759765 bids are invited for 1 boq_1 cleaning charge of bore by backing machine and lifiting of submersible pump from bore well. 2 boq_2 development of tube well by air compressor 10 hours per day with compressed air machine complete with transportation charges and its accessories all as specified and directed. 3 boq_3 pt (peat, humus, andother organic swamp soils) gravell with cartage 4 boq_4 m&l of flanges rubber gasket, nut and bolts complete all as specified and directed 5 boq_5 taking out from bore well submersible pump motor, column pipe with man power/chain pulley arrangement and refixing after development and repair of submersible pump and motor complete in all respects 6 boq_6 m&l for submersible copper cable 4 sqmm 3 core flat type all as specified and directed.make of cable: elecon or equvilent 7 boq_7 material and labour for rewinding of of submersible pump set motor 15 hp capacity including shifting to local workshop gaziabad for repair dismantling and strip opening , cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump incl replacement of spares such as bearing bush gun metal 04 nos (ii) rotor sleeve stainless steel 01 nos (iii) water seal 02 nos (iv) housing ci 02 nos(v) thrust bearing block 02 nos (vi) thrust plate 02 nos and bring back to af stn dadri after repair making all electrical connection on site and testing for smooth functioning of rated dilivery complete all as directed. ...

Northern Railway - Delhi

30731950 supply of dual coat super enamelled copper winding wire of size 18 swg confirming to is:13730 part xiii grade 2.dual coat super enamelled copper winding wire of size 18 swg confirming to is:13730 part xiii grade 2.,dual coat super enamelled copper winding wire of size 18 swg confirming to is:13730 part xiii grade 2....

Military Engineer Services - Delhi

30340862 comprehensive and preventive maintenance of various laundry plants boilers and equipment including connected items at ahrr under ge e / m rrh delhi cantt 110010 1 m &l for comprehensive, preventive and periodical maintenance of various equipments of laundry plantscomprising of opening, dismantling of the washer extractor machine using adequate labour and disconnecting all steam / water connection and electrical connection, cleaning / servicing of steam heating coil, steam trap, installed in main bldg ahrr complex as mentioned here in after, in reliable, safe. smooth, healthy and efficient manner using latest techniques & oem guidelinefor daily / monthly / quaterly / half yearly / yearly maintenance / servicing / lubricating / greasing and adjusting the mechanical and electrical driving equipment, shaft assembly ( filling extra material filling / including granding , welding , reviting ) , bearing / contact, governor jaws in and including change of lubricating oil, grease, all rubber gaskets / packing of all equpment and oil seales as per oem priscription andreplacement of kinds of minordefective / spares parts i.e. wire, lugs, nut, bolts, screw etc and all machine work i.e. welding, cutting, drilling etc as and when required, in and including repair / replacement of defective spares parts mentioned in sch – ‘a’ as supply onlyto entire satisfaction of engineer in charge, complete all as specified anddirected by engr in charge for followinglaundry equipments ( a ) washer extractor upto 120 kg capacity of– 02 nos ( b ) washer extractor upto 60 kg capacity of– 01 nos ( c ) washer extractor upto 100 kg capacity of – 03 nos ( d ) flat work ironer machine of 02 ( e ) flat bed press of 04thecomprehensive / preventive / periodical maintenance includes. the complete records of the replased spare parts, other than mentioned in sch a , will be maintained and will be produced to engineer in charge on monthaly basis or as and when asked to produced the same. all the complaint ( s ) will be addressed within 02 hrs from the time of receipt of complaint. if, contractor or his tradesmen fails to attend the complaint within 02 hrs from the time of receipt of complaint, the compensation / penalty of rs. 500.00 ( rupees five hundred only ) per complaint per hr for first 04 hrs and after that rs. 1000.00 ( rupees one thousand only ) per complaint per hr shall be recovered from the contractor’s dues. all the complaint ( s ) is required to be rectify within 24 hrs or within stipulated time given by the je / engineer in charge. if, contractor or his tradesmen fails to rectify the defect, the compensation of rs. 500.00 ( rupees five hundred only ) per complaint for each day ( i.e. 24 hours ) shall be recovered from the contractor’s dues. the decision of accepting officer in this regard shall be final and binding. the cost of transportation ( to and fro ) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect. the cost of balancing / alignment of cylindrical basket, remattling the shaft by taking it to the lathe work shop complete all as specified anddirected by eic for above mentionedlaundry equipments. 2 supply and fixing, in replacement of main bearing set of size ( 6322, 2rs and 6323, 2rs ) suitable for washer extractor of 120 kg capacityid 125, od 160 and thickness 13 mm complete all as specified anddirected by engr in charge. 3 supply and fixing, in replacement of main bearing seal set of silicon suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. 4 supply and fixing, in replacement of main bearing circlip suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. 5 supply & fixing, in replacement of display controller ( axw ) suitable for washer extractor of 120 / 60 kg capacity fabcare / stefab complete all as specified and directed by engr in charge. 6 supply only, in replacement of main water inlet valve / main drain valve ( actuator butterfly valve ) of size 100 mm suitable for washer extractor of 120 kg capacitycomplete all as specified and directed by engr in charge. 7 supply only, in replacement of main steam inlet solenoid valveof size 25 mmsuitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. make will be as perexisting valve. 8 supply only in replacement of v belt of size b 128 complete set ( 05 nos ) suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. 9 supply only in replacement of ss flexible hose, pressure / temp rating 7 kg / cmsqure / 1000 digricentigrate ofsize1 dia and 2.5 m long for steam inlet suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. make as per existing sample. 10 supply and fixing, in replacement of ss flexible hose, pressure / temp rating 7 kg / cmsqure / 1000 digricentigrate ofdia 2 and 2.5 m longfor water inlet suitable for washer extractor of 120 kg capacity , complete all as specified and directed by engr in charge. make as per sample. 11 supply only, in replacement ofpvc pneumatic pipecomplete all as specified and directed by engr in charge. 12 supply only, in replacement of pvc pneumatic pipe fitting i.e. tee, elbow, connector etc , complete all as specified and directed by engr in charge. 13 supply only v belt of size a 57suitable for flat work ironer machine complete all as specified and directed by engr in charge. 14 supply only, in replacement of ss flexible hose of 2 ¼ size, 1 m long suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. 15 supply only, in replacement of rubber hose pipe of 4 size, 1 m long suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. 16 supply only, in replacement of pneumatic frl set suitable for washer extractor of 120 kg capacity / flat work ironer machinecomplete all as specified and directed by engr in charge. 17 supply only, in replacement of ln key bolt for main housing suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. 18 supply only, in replacement solenoid valve suitable for washer extractorany capacitytape complete all as specified and directed by engr in charge. 19 supply only, in replacement of pneumatic cylinder door lock suitable for washer extractor of 100 / 120 kg capacity complete all as specified and directed by engr in charge. 20 supply only, in replacement of main shocker suitable for washer extractor of 120 kg capacity including nut, bolt and washer complete all as specified and directed by engr in charge. 21 supply only, in replacement of main spring heavy duty suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. 22 supply only, in replacement of door lock latch handle suitable for washer extractor of 120 kg capacity complete all as specified and directed by engr in charge. as per existing sample. 23 supply only, in replacement of thermo couple suitable for flate bed press / washer extractor of 100 kg capacity complete all as specified and directed by engr in charge. make : as per existing sample. 24 supply only, in replacement of flannel cloth suitable for flat work ironer machine complete including anchoring iron rod clip complete all as specified and directed by engr in charge. as per existing sample. 25 supply only, in replacement of final cover suitable for flat work ironer machine complete all as specified and directed by engr in charge.as per existing sample. 26 supply only, in replacement of conveyor beltswith hook & pin suitable for flat work ironer machine complete all as specified and directed by engr in charge. as per existing sample. 27 supply only, in replacement of guide tape suitable for flat work ironer machine complete all as specified and directed by engr in charge.as per existing sample. 28 supply only, in replacement of main bearing set roller suitable for flat work ironer machine complete all as specified and directed by engr in charge. 29 supply only, in replacement of v belt of size a 46 suitable for flat work ironer machine complete all as specified and directed by engr in charge. 30 supply only, in replacement of temperature meter of dia 2 and temp rating 0 200 digricentigrate for flat work ironer machine complete all as specified and directed by engr in charge. 31 m&l for comprehensive maintenance / over hauling of drying trumler of capacity 50 / 60 kg ( make fabcare / stefab ) , comprising of opening, dismantling of the machine using adequate labour and disconnecting all steam / water connection and electrical connection, balancing / alignment of cylindrical basket, remattling the shaft by taking it to the lathe work shop, cleaning / servicing of steam heating coil, steam trap, replacing all defective spares parts / items mentioned in price schedule as supply only and reassembling all dismantled part / items after carrying out necessary repair as required, including cleaning, servicing, oiling, greasing etc, making all water / steam connection and electrical connection, leak testing at desired pressure, with and including testing, commissioning of drying trumbler machine at optimum efficiency as per service manual or as per manufacturer standard, complete all as specified and directed by engr in charge. and required at site. ( a ) drying trumblern 60 kg make fabcare 04 ( b ) drying trumblern 50 kg make stebfab 03note: the cost of transportation ( to & fro ) is deemd to be included in quoted rates. 32 supply only, in replacement of steam heating coil having copper tube with aluminium fins suitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 33 supply only, in replacement of v belt of size a 102 of main drivesuitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 34 supply only, in replacement of v belt of size b 82 suitamle for ideler drivesuitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 35 supply only, in replacement of steam trap suitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 36 supply only, in replacement of main drive bearing of size 2210alongwith sleeves suitable for drying tumblers of 50 / 60 kg capacity complete all as specified and directed by engr in charge. 37 supply only, in replacement of idler drive bearing of size 2213 alongwith indler sleeves suitable for drying tumblers of 60 kg capacitycomplete all as specified and directed by engr in charge. 38 supply only, in replacement of door latches for lint screen suitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 39 supply only, in replacement of door limit switch suitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 40 supply only, in replacement of main door lock suitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 41 supply only, in replacement of timer 0 60 sec time delay suitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 42 supply only, in replacement of timer rev fwd action suitable for drying tumblers of 60 kg capacity complete all as specified and directed by engr in charge. 43 supply only, in replacement of digital temperature controller suitable for drying tumblers of 60 kg capacity / flat bed press complete all as specified and directed by engr in charge. 44 supply only, in replacement of padding set suitable for flat bed press complete all as specified and directed by engr in charge. 45 supply only, in replacement of main bearing suitable for flat bed press complete all as specified and directed by engr in charge. 46 supply only, in replacement of flow control valve of size 1 / 2 inch ( 15mm ) suitable for flat bed press complete all as specified and directed by engr in charge. 47 supply only, in replacement of air valve of size 15 mm for manual control suitable for flat bed press complete all as specified and directed by engr in charge. 48 supply only, in replacement of steam supply valve of size 20 mm suitable for flat bed press complete all as specified and directed by engr in charge. 49 supply only, in replacement of steam trap td 3 type of size 25 mm suitable for flat bed press complete all as specified and directed by engr in charge. 50 supply only, in replacement of timer gic type suitable for flat bed press complete all as specified and directed by engr in charge. 51 supply only, in replacement of ss flexible steam inlet pipe of size 20 mm suitable for flat bed presscomplete all as specified and directed by engr in charge. 52 supply only, in replacement of white nipples suitable for flat bed press complete all as specified and directed by engr in charge. 53 supply only, in replacement of red / green push button, complete all as specified and directed by engr in charge. 54 supply only, in replacement of indicator lamp, complete all as specified and directed by engr in charge. 55 m&l for comprehensive maintenance / overhauling of hydro extractor capacity of 25 kg ( make stefab ) , comprising of opening, dismantling and disconnecting all electrical connection, balancing / alignment of cylindrical basket, balancing of blower, shaft turning, cleaning / servicing of steam radiator, replacing all defective spares parts / items mentioned in price schedule as supply only. the work include taking down of 3 ph induction drive motor and neccessary turning & grinding of motor rotor and reassembling all dismantled part / items after carrying out necessary repair as required, including cleaning, servicing, oiling, greasing etc, making all water connection and electrical connection, leak testing at desired pressure, with and including new control wiring and testing, commissioning of hydro extracor at optimum efficiency as per service manual or as per is standard, complete all as specified and directed by engr in charge. 56 supply only, in replacement of, transformer of 15 amp capacity suitable for hydro extractor of 25 kg capacitycomplete all as specified and directed by engr in charge. 57 supply only, in replacement of buffer suitable for 25 kg hydro extractor complete all as specified and directed by engr in charge. 58 supply only, in replacement of oil seal suitable for 25 kg hydro extractor complete all as specified and directed by engr in charge. 59 supply only, in replacement of limit switch suitable for 25 kg hydro extractor complete all as specified and directed by engr in charge. 60 supply only, in replacement of spring suitable for 25 kg hydro extractor complete all as specified and directed by engr in charge. 61 servicing of existing screw / reciprocating type air compressor of any make / model, by engaging sufficient man power and suitable t&p to ensure safety of plant as well as working persons including disconnecting of air / electric connections, dismantling of air compressor by unscrewing / cutting of screws, nuts & bolts etc, dismantling of air filter, unserviceable parts / items, air receivers, moisture separator, air suction silencer and fixing the new spare part as given below, replacing complete oil with new oil of recommended make & grade, adjusting / balancing the compressor parts / items including all machine works i.e. welding, cutting, drilling etc as and when required and reassembling the compressor, making electric connection and testing for leakage, required air pressure & suction temperature etc, complete all as specified and directed by engr in charge.the cost of transportation ( to and fro ) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect. the defective spares parts / items will be measured and paid separately under respective items only. the replacement cost ( labour charges ) for all defective spares parts / items mentioned in boq ( sch – ‘a’ ) here in afteras supply only, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect at any stage. ( i ) the air compressor will be handed over to contractor in as and where condition. hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract. no claim on condition of air compressor will be accepted at later stage and bidder is deemed to have visited the site to ascertain the condition of air compressor. ( iii ) the cost of any spare part ( s ) , other than specified here in above and which are essential to be replaced for smooth working of compressor is deemed to be included in quoted rates and no extra cost shall be paid to the contractor on this account. ( iv ) the cost of all kind of repair includingminor items i.e. wire, lugs, nut, bolts, screws etc, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor on this account. ( v ) the entire work shall be carried out by the oem or auth dealer of the oem only. 62 supply only crank shaft 63 supply only cylender sleeve lp +hp 64 supply only piston lp+hp 65 supply only piston ring lp+hp 66 supply only fingar valve lp+hp 67 supply only air filter assy 68 suuply only nrv assy 3 / 4 69 supply only bearing 70 supply only gasket 71 supply only oil indictor breather valve 72 supply only compressor oil of suitable grade / make 73 supply & fixing in replacement of digital ammeter of size 96mm x 96mm, three phase, 5a, class i with inbuilt selector switchcomplete all as specified and directed by engr in charge. 74 m&l for preventive and periodical repair / overhauling of steam boiler of 850 / 650 kg capacity ( make : thermax rxd ) by engaging sufficient man power and suitable t&p to ensure safety of boiler plant as well as working persons including disconnecting of water / steam / electric connections, dismantling of boiler plant by unscrewing / cutting of screws, nuts & bolts etc, taking out complete coil assembly and other major parts from the boiler etc, replacing all defective spares parts ( spare parts shall be measured and paid seperately assupply only in respective items catered here in after ) cleaning / servicing of coil assemblyincl electrical control panel board, all machine works i.e. welding, cutting, drilling etcas and when required and reassembling all dismantled part / items after carrying out necessary repair as required, other material, cleaning, servicing, oiling, greasing etc, making all steam / water connection and electrical connection, leak testing at desired pressure, with and including testing, commissioning of complete boiler plant in original location for smooth and trouble free operation, to entire satisfaction of engineer in charge, complete all as specified and directed by engr in charge.note : the entire work incl spare parts / items, as mentioned in srl item no 75.00, shall be got executed through oem i.e. m / s thermax ltd only. the defective spares parts / items will be measured and paid separately under respective items only. the replacement cost ( labour charges ) for all defective spares parts / items mentioned in boq ( sch – ‘a’ ) here in afteras supply only, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect at any stage. the boiler plants will be handed over to contractor in as and when condition and cost of all kind of repair incl minor items i.e. wire, lugs, nut, bolts, screws etc, other than mentioned in sch a, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract. the cost of transportation ( to and fro ) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect. 75 supply only limit switch suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 76 supply only coil rxd 850 for 850 kg / hr boiler hsn / sac 84029020 , part no prxcl10002model : rxd / 850 complete all as specified and directed by engr in charge. 77 supply only sequence controller ma 810 suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 78 supply only burner rod suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 79 supply only metallic hose pipe 3 / 8 x 40 size suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 80 supply only ss diffuser plate 132 mm suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 81 supply only insulyte 7 low density insulating castable suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 82 supply only electronic sequence timer suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 83 supply only thermocouple k type ss310 for primary chamber suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 84 supply only safety relief value suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 85 supply only resin t 40 na complete all as specified and directed by engr in charge. 86 s&f, in replacement, of rtdpt 100 temperature sensor output, complete all as specified and directed by engr in charge. 87 s&f, in replacement, of rtd temperature controller 0 1200ºc, k type input, complete all as specified and directed by engr in charge. 88 supply onlyoil filtersuitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 89 supply onlyignition electrode suitable for steam boiler of 850 / 600 kg capacity complete all as specified and directed by engr in charge. 90 supply onlyphoto ignition electrode suitable for steam boiler of 850 / 600 kg capacity complete all as specified and directed by engr in charge. 91 supply onlyfuel pump aj6ac suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 92 supply only valve seat assembly for triplex pump suitable for steam boiler of 850 kg capacity complete all as specified and directed by engr in charge. 93 supply only maxtreat 3220 solution for water softning plant complete all as specified and directed by engr in charge. 94 supply only maxclean 05 descaling chemical for boilerplant complete all as specified and directed by engr in charge. 95 supply only maxtreat 3004 solution for water softning plant complete all as specified and directed by engr in charge. 96 supply only hardness kit for testing of water complete all as specified and directed by engr in charge. 97 m&l for dismantling of electric driven horizontal induction motor of upto 2.0 hp capacity of any type and make, by engaging sufficient man power and suitable t&p to ensure safety of pump motor as well as working persons including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity ( as per original manufacturer design ) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper ( class f ) , sealing compounds etc and reassembling the motor after varnishing, heating / drying, greasing of moving parts etc and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as specified and directed by engr in charge. note : ( i ) the cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. ( ii ) thecost of transportation ( to and fro ) and other necessary equipment shall be arranged / brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect. 98 all as per srl item no 97 here in above but for 5.0 hp capacity, 3 ph, 415 volt, 50 hz ac. 99 all as per srl item no 97 here in above but for 10.0 hp capacity, 3 ph, 415 volt, 50 hz ac. 100 all as per srl item no 97 here in above but for 30.0 hp capacity, 3 ph, 415 volt, 50 hz ac. 101 supply and lay ms pipe pipe in replacement 20 mm bore heavy grade with all fittings laid in floors or ffixed to walls and ceiling etc complete all as specified and directed by engr in charge. 102 all as per item no. 101 here in before but for pipe size of 25 mm dia. 103 all as per item no.101 here in before but for pipe size of 32 mm dia. 104 all as per item no.101 here in before but for pipe size of 40 mm dia. 105 all as per item no. 101 here in before but for pipe size of 50 mm dia. 106 all as per item no. 101 here in before but for pipe size of 65 mm dia. 107 all as per item no. 101 here in before but for pipe size of 80 mm dia. 108 all as per item no. 101 here in before but for pipe size of 100 mm dia. 109 m & l for under deck insulation forms pipe of 20 mm to 100 mm dia size with glass wool of denisity 48 kg / cum suitable for factory laminated with aluminum foil and providing additional support to insulation with amd including chickenwire mesh , with an include applying bituminus compound and gi clading of 26 guage gi sheet with inc. taking down of old insulation and preparing of pipe surface by sctraching / removing rust , dust and old paints etc. with wire brush , emery paper , grinder etc and making surface smooth complete all as specified and directed by engr in charge. 110 s&f in replacement bronze globe steamstop valve of size 50 mm dia as per isi 778 , class 2 gun metal body ( is 318ltb2 ) , screwed in bonnet, out side screw and yoke type rising stem , test pressure 500psig. hydraullic , working pressure 250psig at 450degree farenhite hsn code 84818030, complete all as specified and directed by engr in charge. 111 all as per srl item no 110 here in above but 80 mm dia size. 112 all as per srl item no 110 here in above but 25 mm dia size. 113 s&f, in replacement, 6 dia caster wheel, swivel type, heavy duty, with supporting base plate bracket complete with nut and bolts etc of existing shape and size suitable for washroom trolley, complete all as specified and directed by engr in charge. 114 s&f in replacement, 6 dia caster wheel, fixed type, heavy duty, with supporting base plate bracket complete with nut and bolts etc of existing shape and size suitable for washroom trolley, complete all as specified and directed by engr in charge. 115 supply only pvc container trolley as per existing size / sample suitable for carry patiant cloths complete all as specified and directed by engr in charge. 116 supply only crystal type salt of sodium chloride 25 kg bag for water softening plant @ 3 kg / day complete all as specified and directed by engr in charge. 117 supply & fixing in replacement, of mccb 40 amp, 4 pole, 18 ka, c curve, complete all as specified and directed by engr in charge. 118 supply & fixing in replacement, of mccb 63 amp, 4 pole, 18 ka, c curve, complete all as specified and directed by engr in charge. 119 supply & fixing in replacement, of mccb 125 amp, 3 pole, 36 ka, ics = 100% icu, with adjustable thermal magnetic setting alongwith spreader terminals and phase barriers, complete all as specified and directed by engr in charge. 120 all as per srl item no. 119 here in before but 36 ka 250 amp capacity. 121 all as per srl item no. 119 here in before but 36 ka 160 amp capacity. 122 supply only, in replacement of brake timer 0 60 sec time delay suitable for 25 kg hydro extractor complete all as specified and directed by engr in charge. 123 supply only, in replacement of, diode 10hi cn 25d suitable for 25 kg hydro extractor complete all as specified and directed by engr in charge. 124 supply only, in replacement of, over load relay suitable for hydro extractor of 25 kg, 5 hp motor capacity complete all as specified and directed by engr in charge. 125 supply only, in replacement of timer 0 15 sec time delay suitable for 25 kg hydro extractor complete all as specified and directed by engr in charge. 126 supply only, in replacement of 3 ph, 415 volt , contactor, mnx 18 amps with neccessary no & nc aux contact complete all as specified and directed by engr in charge. 127 supply only, in replacement of 3 ph, 415 volt , contactor, mnx 25 amps with neccessary no & nc aux contactcomplete all as specified and directed by engr in charge. 128 supply & fixing in replacement of power contactor of 32 amp ac3 rating, 03 pole, mnx32 with no+nc aux contacts, 415vwith and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed by engr in charge. 129 supply & fixing in replacement of power contactor of 40 amp ac3 rating, 03 pole, mnx40 with no+nc aux contacts, 415vwith and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed by engr in charge. 130 supply & fixingin replacement of power contactor of 25 amp ac3 rating, 03 pole, 415 v, ml 1.52no+2nc contactswith and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed by engr in charge. 131 supply & fixingin replacement of power contactor of 25 amp ac3 rating, 03 pole, 415 v, ml31 2no+2nc aux contactswith and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed by engr in charge. 132 supply & fixing in replacement of over load relay mn2 range 20 33 amps, with built in single phase preventer, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as specified and directed by engr in charge. 133 all as per srl item no 132 here in above but 14 23 amps capacity. 134 all as per srl item no 132 here in above but 4.5 7.5 amps capacity. 135 supply and fixing of multi port valve for water softening plant 50 mm pressure 5 kg / cm2 complete all as specified and directed by engr in charge. 136 s&f, in replacement of three phase mk1 dol starter, in sheet metal enclosure with 4p, ac3 duty contactor, 4p over load relay and single phase protection suitable for7.5 hp, 3 ph, 415 volt ac, 50 hz electric motorincl making all electric connection, complete all as specified and directed by engr in charge. 137 s&f, in replacement of three phase fully automatic star delta starter mn 16 fasdstarter, in sheet metal enclosure type with 4p, ac3 duty contactor, 4p over load relay and single phase protection suitable for 15 hp, 3 ph, 415 volt ac, 50 hz electric motor with relayrange 14 23incl making all electric connection, complete all as specified and directed by engr in charge. 138 s&f, in replacement of three phase fully automatic star delta starter mn 32 fasd starter, in sheet metal enclosure typewith 4p, ac3 duty contactor, 4p over load relay and single phase protection suitable for 25 hp, 3 ph, 415 volt ac, 50 hz electric motor with relayrange 14 23incl making all electric connection, complete all as specified and directed by engr in charge. 139 s&f, in replacement of off load change over switch ac 21 ( side handle ) , having powder coated sheet metal enclosure, 400amp, 03 phase, 415 volt, complete all as specified and directed by engr in charge. 140 m&linreplacement of rubber packing for lint screen suitable for washer extractor of capacity 120 / 100 kgcomplete all as specified and directed by engr in charge. 141 m&l forapplying one coat synthetic enamelledpaint as desired colour over a coat of red oxideprimer on steel / iron surfaces of pipes after preparing surface with help of emery paper etc removingrust, dust and old paintsand making surfaces smooth for achieving better grip between surface and primer complete all as specified and directed by engr in charge. 142 dismantling of floor, hearth or wall tiling including cement mortar bedding ( but not backing ) and removing rubbish off premises min 500m away from bldg complex, complete all as specified and directed by engr in charge. 143 demolition of cement concrete ( unreinforced ) as in any positionn.exc. 15 cm below or above ground level and removing rubbish off premises min 500m away from bldg complex, complete all as specified and directed by engr in charge. 144 material and labour for machine cut kota stone flooring 20 25 mm thick of approved size over cement screed base, laid and jointed with grey cemented slurry mixed with pigment to match the shade of slab including rubbing and polishing ( mirror ) , complete all as specified and directed by engr in charge. 145 material and labour for 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying kota stone floor finishes, complete all as specified and directed by engr in charge. 146 m&l for preparation of old decorated wall surfaces including washing rubbing down and stopping of distempered surfaces and applying a coat of distemper oil emulsion on wall surfaces, complete all as specified and directed by engr in charge. 147 s&f of thermal insulation on new / existing ducts and plenum chamber, comprise of preparation of surface and fixing of new cross linked closed cell polythene, plane, fire retardant insulation of 9 mm thick nitrile insulation with aluminium foil of the ducthaving a tow stable k value of 0.027 0.029 kcal / hr / m at 0 23°c with minimum density of 33 kg / cum, fire retardant self extinguishing on dripping, good ozone resistance, including fixing the insulation to the duct surface with help of adhesive paste and closing the gap with self adhesive tape of 3mm thick, complete all as specified and directed by engr in charge....

Defence Research And Development Organisation - Delhi

30128956 supply of consumables for air conditioning items for drdo bhawan, new delhi 1 wires and cables : 2 supply of 6 sqmm single core pvc insulated copper conductor cable. 3 supply of 3c x 2.5 sqmm pvc insulated, unsheathed multistranded copper conduct wire. 4 supply of 4c x 10 sqmm 1.1 kv, xlpe insulated armound copper conductor cable. 5 supply of 3 core x 1.5 sqmm copper wire 6 supply of 3 core x 1 sqmm copper wire 7 supply of 4 core x 1 sqmm copper wire 8 exhaust fans : 9 supply of 250 mm sweep ventilating fan. 10 mcbs / mccbs / mpcbs : 11 supply of following ratingmccb / mpcb. 12 100 a tp mccb, 25 ka 13 20 25 a mpcb, 15 ka 14 32a, 10ka, dpmcb 15 gi pipes and fittings : 16 supply of 20 mm dia class b gi pipe. 17 supply of 25 mm dia class b gi pipe. 18 supply of 40 mm dia class b gi pipe. 19 thimbles / nut / bolts / washer : 20 supply of thimbles suitable for following cable. 21 6 sqmm ring type copper 22 16 sqmm ring type copper 23 10 sqmm copper thimble 24 35 sqmm copper thimble 25 supply ofnut, bolts. 26 nult bolt6 mm x 40 mm 27 nult bolt 10 mm x 40 mm 28 contactor / relays / indication lamps : 29 supply of followingcontactor suitable to work on 240 / 415 v hz 30 contactor mnx 18 a tp 31 contactor mnx 25 a tp 32 supply of relay mn2 9 15 amp suitable for 230v / 415v, 50 hz. 33 supply of led indication lamp red / green / yellow / blue. 34 supplyof add on block 2 no + 2 nc on existing contactors. 35 supplyof three phase voltmeter digital type 0 500 v class 1 . 36 ballvalves and flanges : 37 supply of following dia ball valve. 38 1 / 4 39 5 / 8 40 3 / 4 41 1 / 2 42 supplyof ms flanges / nozzles. 43 ms blind flange 10 44 ms blind flange 8 45 nozzle pp 46 inline fan with motor : 47 supplyof inline bare fan, impeller & motor 0.75 kw all complete. 48 supplyof alkaline battery 9 volt. 49 hvac items: 50 supplyof gases, refrigerant and tools related to hvac. 51 r 22 52 r 407 53 r 410 54 r 134 a 55 n2o 56 o2 57 supply of condensor coil of 2 tr capacity. 58 bearing : 59 supply of bearing of following size. 60 i ) 6309 61 ii ) 1209 gk 62 iii ) 2309 k 63 iv ) h 2312 64 v ) uk 211 65 vi ) ukp 212 66 vii ) 32309 67 viii ) pillow bearing p212 j 68 supplyof valves of following size. 69 pin valve 1 / 4 70 bib cock brass with syphon 71 butterfly valve 200 mm 72 butterfly valve 250 mm 73 nrv 200 mm 74 cooling tower spares: 75 supplyof following cooling tower spares. 76 fill retainer cap 77 fill sheet 6x4 78 frp kit for leakage 79 gear support box 80 15hp capacity motor 81 pillar support 82 ss hanger 83 coil shine 84 gear oil 90 grade 85 cooling tower blade with seat 86 supplyof following spares of pump / motor 15hp all complete as specified and directed. 87 mechanical shaft seal 88 mechanical seal bush 89 air seal 102 x 7.5 gi 90 air seal 24 x 12 gi 91 rubber coupling 0.14 92 rubber coupling 0.15 93 float valve 1 94 supplyof temperature indicator controller. 95 paint : 96 supply ofsynthetic enamel paint of approved colours. 97 supply of frp putty 98 repair and service : 99 repair / rewinding the electric motor / monoblock pump set with super enamelled copper winding copper winding wire of existing gauge and turn including helping material such as varnish, cotton tape, pvc tape, glasswire, sleeve, thimble all complete as specified and directed but of following capacity : 100 i ) 10 hp 101 ii ) 15 hp 102 iii ) 30 hp 103 supply of cooling tower fills including cleaning, fixing, mechanical work and service charges all complete as specified and directed. 104 supply of unservicable pcbs of split / window air conditioners. 105 window ac 1.5 ton 106 split ac 1.5 / 2 ton 107 supply of rotary compressor of existing following capacity for window / split airconditioners all complete as specified. 108 rotatry compressor 1.5 / 2 tr 109 supplyof motor of existing following capacity all as specified and directed. 110 condenser motor 93 w 111 water cooler motor 3 / 4 hp. 112 condenser fan motor 25 w 113 supply of float valve 1 / 2 for water cooler 114 supply of pressure gauge 115 supply of temperature gauge 116 supply of water cooler bib cock long 117 supply of water cooler bib cock short 118 supply of belt b 97 119 supply of belt b 96 120 supply of belt b 110 121 supply of o ring replacement 122 supply of 15 amp 3 pin top 123 supply of batten 1 ( length 2 metre ) ) 124 supply of pvc box 3x3 125 supply of thermostate 126 supply of damper actuator 127 supply of electrical transformer 24 volt 128 supply of motorised damper with thermostate 129 supply of flexible duct 8 130 supply of normal damper 131 supply of firoja paint 132 ms. pipe 3 class c 133 ms. pipe 4 class c => limited...

Archaeological Survey Of India - Delhi

28498984 for supply of materials under the work sr to independence day celebration 2021 at red firt for supply of materials under the work sr to independence day celebration 2021 at red fort , civil work , providing supply & purchasing ofessential articles for the execution of work during independence day 2021 wire brush [each] , coir brush [each] , poucha big size [each] , duster [each] , sweeper broom with handle [each] , phynel ( klinjo 5 ltr . cane ) [each] , finite ( 5 ltr . cane ) [each] , acid bottle [each] 500 ml , floor cleaner ( wiper ) [each] , nylon brush with handle [each] , naphthalene ball [kg] , narial rope 1 dia [kg] , hose pipe 4 dia [rmt] , pvc suction pipe 2 [rmt] , foot valve of engine 4 [rmt] , bucket pvc [each] 15 liter capacity , pvc mug . [each] large size , pvc jug [each] , sweeper broom [kg] , narial broom [each] , phool broom [each] , nylon dori [kg] , cane basket [each] , hack saw iron & wooden [each] , nail screws differ . size [ls] , agro shed net ( green color ) [rmt] 3m wide , s . s wire supporting to flag post 12 to 15 mm [rmt] , petrol [ltr] , provision for purchasing of stationary articles during independence day celebration glossy paper , a 4 rim , printer ink set , provision for repair charges of desktop such as new hardisk , ram , repair charges of mother board etc complete . [ls] , ply wood for covering the fort wall chattries opening of size 3 . 5x3 . 5 meter 12mm thick ( as per mod direction ) [each] , provision for repairing charges of fogging machine ( as per mod direction ) [each] , fiber sheet [rmt] , diesel [ltr] , cartage charges [ls] , portable washbasin , water dispenser , kerosene oil , provision for providing and fixing of electrical articles i . e copper wires , switch , socket , led lights , cables , mcb , chowk , starter etc for temporary arrangement for various army personnel deployed at red fort during independence day celebration 2020 [each] 10 sqmm copper wire havells [each] , 6 sqmm copper wre havells [each] , 4 sqmm copper wire havells [each] , 2 . 5 sqmm copper wire havells [each] , 1 . 5 sqmm copper wire havells [each] , 10 sqmm 2 core aluminium wire kalinga [each] , 10 sqmm 2 core aluminium wire kalinga ( each ) , tube 36 watt isi marked [each] , 16 amp 3 pin top isi marked [each] , 6 amp 3 pin top isi marked [each] , 16 amp power combine with box isi marked [each] , pandenant holder isi marked [each] , 100 watt bulb isi marked [each] , water proof tape roll isi marked [each] , pvc tape roll isi marked [each] , cotton tape isi marked [each] , tpn isolator isi marked 100 amp [each] , 1 pvc pipe isi marked [each] , 1 pvc batten isi marked [each] , 6mm telephone gitti [each] , 63 amp tpn isolater isi marked [each] , dp mcb box isi marked [each] , 63 amp dp mcb isi marked [each] , 40 amp dp mcb isi marked [each] , 32 amp dp mcb isi marked [each] , 7 . 5 hp starte panel for fountain motor isi marked [each] , 32 amp mcb isi marked [each] , 16 amp mcb isi marked [each] , bottle type thimble aluminium [each] , 25mm bottle type thimble aluminium [each] , 25mm ring type thimble aluminium [each] , ceiling fan 48 crompton/usha [each] or equivalent , exhaust fan 12 crompton [each] or equivalent , pedestral fan crompton [each] or equivalent , wall fan crompton [each] or equivalent , 36 watt tube fitting complete isi marked [each] , 100 watt led flood lights isi marked [each] , led lights 110 watt for pole isi marked [each] , 6 amp switch isi marked [each] , 6 amp socket isi marked [each] , 16 amp switch isi marked [each] , 16 amp socket isi marked [each] , 3 . 15 mfd fan capacitor isi marked [each] , wooden screw 1 . 5 [each] , pvc gutty 1 . 5 [each] , fan regulator isi marked [each] , 11x13 sheet [each] , 9x11 sheet [each] , 8x5 sheet [each] , gi winding wire [each] , 6mm hammer bit [each] , nut bolt warsel [each] , voltage meter ( multi meter ) [each] , electrical tools ( plier and screw driver set etc . ) , brass screw 1 . 5 [each] , brass screw 1 [each] , cable tie 9 [each] , bed switch [each] , cfl 18 watt [each] havells/philips or equivalent , cartage charges , air cooler usha/symphony or equivalent , provision for purchasing , supplying and fixing of sanitary articles including all labour and material etc compete . [each] gi pipe 6 dia 10 foot length [each] , gi 4 dia nipple 4 length [each] , gi 4 flench [each] , gi 2 socket [each] , gi 4 nipple [each] , gi 2 nipple [each] , gi 1/2 hex nipple [each] , gi 1/2 socket [each] , gi 1/2 elbow [each] , 2 clamp [each] , ppr pipe 1 10 foot length [each] , ppr 1 elbow [each] , ppr 1 socket [each] , ppr 1 f tee [each] , ppr 1 m tee [each] , 2 brass ball valve [each] , safeda [kg] , thread [each] , nut bolts3 ( 4 soot ) [each] , hexa blade [each] , m seal [kg] , double symphon [each] , cistern complete set [each] pvc , towel rod [each] s . s , towel ring [each]s . s , soap container [each] s . s , short pillar cock [each]c . p , long body cock [each] c . p , cap [each] , cpvc 1 ball valve [each] , cpvc 1 pipe [each] , cpvc 1 socket [each] , cpvc 1 elbow [each] , cpvc t 1 [each] , cpvc union 1 [each] , cpvc 1 ball valve [each] , cpvc 1 f t [each] , cpvc 1 mt [each] , cpvc 2 ball valve [each] , cpvc 2 pipe [each] , cpvc 2 socket [each] , cpvc 2 socket [each] , cpvc t 2 [each] , cpvc union 2 [each] , cpvc 2x1 reducer [each] , cpvc plug cap 2 [each] , cpvc plug cap 1 [each] , cpvc 3/4 t [each] , cpvc 3/4 socket [each] , cpvc 3/4 elbow [each] , cpvc cap 3/4 [each] , cpvc union 3/4 [each] , cpvc tank nipple 3/4 [each] , 3/4 ball cock brass [each] , tank nipple 1 [each] , ft 3/4 [each] , hand spray ss [each] ( health faucet ) , angle valve [each] , pvc connection pipe 2; [each] , cp cap [each] , 2in1 toti [each] taps , european seat cover [each] pvc , sintex tank 500 litre for army [each] triple layer , plumber tools [each] , 1 ball cock brass [each] , cpvc solvent [each] , 3/4 ball cock brass [each] , gi nipple 6 length x 1 dia [each] , gi nipple 9 length x 1 dia [each] , cpvc elbow 1 [each] , cpvc socket 1 [each] , submersible electric motor 1 hp crompton [each]or equivalent , rubber pipe 1 [each] , sintex tank 500 liter [each]double layer , cartage charges for above articles , provision for purchasing of essential articles for taking the precautionary measures against covid 19 including ppe kit , mask , sanitizer etc masks n 95 [each] , sanitizer [ltr] , ppe kits [each] , face shields [each] , engagement of manpower as detailed below for various miscellaneous works pertaining to independence day celebration 2021 at red fort , delhi electrician ( skilled ) , plumber ( skilled ) , carpenter ( skilled ) , driver ( skilled ) , sweeper ( unskilled ) ...

Airports Authority Of India - Delhi

27715807 armo of internal and external electrical installations at aai transit guest house and aai kendriya vidyalaya , rangpuri , new delhi ( 2021 23 ) , sh i: operation & maintenance operation & maintenance of internal & external electrical installations i / c fire fighting system , operation of dg set and pumping set at aai transit guest house , aai kendriya vidyalaya and paper recycling unit ( excluding factory machinerey ) . the deputing staffs shall note down the compaint in complaint register and attend the complaint for immediate follow up action by arranging the store material . the following minimum manpower shall be provided by agency on all working days i / c sunday & holidays and releiver shall be provided on weekly off . a ) operator cum wireman 03 nos . ( 1 no . each in three shifts per day ) ; b ) khallasi 03 nos . ( 1 no . each in three shifts per day ) , fuel cost for running of the following capacity kirloskar make dg set per hour basis ( contractor has to quote their rate for running hours i / c handling , storing and transportation cost of fuel , the rate shall be assessed according to the location and capacity of dg set mentioned below as per special conditions of the tender . , 1x125 kva , 1x62 . 5 kva , 1x10 kva , sh ii: supply of electrical spares & accessories supply of flame retardant pvc insulated single core copper conductor ( flexible ) cable suitable upto 1100v grade conforming to is:694 / 1990 with latest amendments of aai approved make of following size: , 1 x 1 . 5 sqmm ( 90 mtr coil ) , 1 x 2 . 5 sqmm ( 90 mtr coil ) , 1 x 4 . 0 sqmm ( 90 mtr coil ) , supply of pvc insulated & pvc round sheathed copper conductor ( flexible ) industrial cable ( multicore ) , 1100v conforming to is:694 / 1990 with latest amendments of aai approved make of following size: , 3 x 1 . 5 sqmm ( 100 mtr coil ) , 3 x 2 . 5 sqmm ( 100 mtr coil ) , 3 x 4 . 0 sqmm ( 100 mtr coil ) , supply of following size xlpe insulated pvc sheathed aluminium conductor armoured power cable of 1 . 1kv grade conforming to is:1554 ( part i ) with upto date amendment complete as required . , 4 x 16 sq . mm . , 4 x 25 sq . mm . , supplying of following size of pvc casing and capping as per aai approved make list as required . , 20mm x 12mm , 25mm x 16mm , 6 32 a , 10 ka , sp mcb , c series , 6 32 a , 10 ka , dp mcb , c series , 6 32 a , 10 ka , tpn mcb , c series , isolator 100amp ( fp ) , industrial plug & socket box with metal cover 20 a with 20 a spn mcb , c series , supply of following rating and breaking capacity mccbs : , 250a , 36ka , fp mccb , 250a , 36ka , tp mccb , 125a , 25ka , tp mccb , 100a , 25ka , tp mccb , 32 63a , 25ka , tp mccb , 3 pin top 6 amp , 3 pin top 16 amp , piano type 5 / 6 amp switch , piano type 3 pin 5 / 6 amp socket outlet , piano type 16 / 20 amp switch , 20 & 10 amp , uni socket outlet , 20 & 10 amp switch socket combined with box , pvc tape , electronic fan regulator ( step type ) , capacitor 2 . 0 mfd / 2 . 5 mfd , capacitor 4mfd , ceiling fan ( 1200 mm sweep ) , wall mounting fan ( 400 mm sweep ) , 9 watt led bulb ( b22 ) , 15 watt led bulb ( b22 ) , 18 / 20 watt extruded aluminium retrofit led tubelight , supply of lead acid batteries 12v , 150ah capacity in charged condition , as & when required . , supply of desert coolers made of gi sheet body of 20 gauge of dimension 5ftx2ftx3ft with fan and pump and all accessories complete as required . , supply of desert coolers made of gi sheet body of 20 gauge of dimension 2ftx2ftx3ft with fan and pump and all accessories complete as required . , supply of cooler pads suitable for standard size desert cooler as per site requirement , supply of desert cooler pump of isi marked suitable for 220v ac supply . , refilling of water type fire extinguishers of 9 ltr . capacity , etc . as required . , refilling of co2 type , 4 . 5 kg fire extinguishers as required . , sh iii: painting works painting of fire fighting pipe line after scrapping with emery / sand paper to get a smooth surface and painting with one coat of primer and two or more coat synthetic enamel paint of approval brand and manufacture to give an even shade complete as required . , painting of 100 mm dia pipe only , painting of 80 mm dia pipe to 65 mm dia pipe only . , painting of 25 mm dia pipe . , painting of first aid hose reel drum including accessories with pipes etc . complete after scrapping with emery / sand paper to get a smooth surgace and painting with two or maore coat or synthetic enamel paint of approved brand and manufacture to give an even shade complete as required . , painting of desert cooler as per site requirement . , painting of distribution boards / out door panel etc . in installed position with synthetic enamelled paint by spray / brush painting by one or more coats i / c scrapping , cleaning of surface & writing actual nomenclature with highlighted colour on the installation after painting , etc . complete as required . , sh iv: rewinding & repairing of submersible pumps rewinding of following pump motors etc . as & when required with super enemelled copper winding wire , varnishing including greasing replacement of bearings / bush , thrust support plate , repairing / replace of shaft including transporatation charges completed as required . ( dismantle material belongs to the contractor ) , 12 . 5 hp , 3 phase water pump ( fire system ) , 5 . 0 hp , 3 phase submersible pump , 1 . 5 hp , 3 phase mono submersible pump , 5 . 0 hp , 3 phase booster pump , 1 1 . 5 hp , single phase water pump , rewinding of following as per original characteristics with super enameled copper wire and e class insulation material repairing / replacing the worn out bearing etc . complete as required . , ceiling fan as & when required . , exhaust fan upto 450mm as & when required . , lifting & lowering charges of mono submersible pump set upto required depth of underground tank i / c water proof cable jointing including transportation of special tools and plants etc . as reqd . , charges for lifting & lowerig of submersible pump set alongwith pipe lines , cable from existing bore , as & when required i / c cost of labour , tools & plants , waterproof cable jointing & minor items such as nut bolt , rubber packing , etc . as required . , sh v: dsr items execution of works as per requirement of site from cpwd schedule of rates ( electrical dsr 2018 ) as per cpwd specifications complete as required ( total amount of rs . 50000 . 00 ( exclusive of gst ) is kept for dsr items 2018 ) [ ( note rate of dsr items shall be quoted against total amount of rs 50000 . 00 ( fifty thousand ) in figures excluding gst which shall be converted in the percentage ( above / below ) and rate of dsr items shall be taken exclusive of gst ( basic rate ) on which payment shall be made considering percentage above / below rate quoted against rs . 50000 . 00 ] ...

Archaeological Survey Of India - Delhi

24616408 special repair to independence day celebration 2020 at red fort, delhi. supply of materials: 2 providing supply & purchasing of essential articles for the execution of work during independence day 2020 [ each ] : wire brush 3 coir brush 4 poucha big size 5 duster 6 sweeper broom with handle 7 phynel ( klinjo 5 ltr. cane ) 8 finite ( 5 ltr. cane ) 9 acid bottle 10 floor cleaner ( wipper ) 11 nylon brush with handle 12 naphthalene ball 13 narial rope 1 dia 14 desert cooler 15 hose pipe 4 dia 16 pvc suction pipe 2 17 foot valve of engine 4 18 bucket pvc 19 pvc mug. 20 pvc jug 21 sweeper broom 22 narial broom 23 phool broom 24 nylon rope 25 cane basket 26 hack saw iron & wooden 27 nail screws differ. size 28 agro shed net ( green color ) 29 s.s wire12 to 15 mm 30 ply wood of size 3.5x3.5 meter 12mm thick 31 fiber sheet [ rmt ] 32 sofa set ( 3+1+1 seater ) 33 wooden table ( 5x25 ) ] 34 provision for providing and fixing of electrical articles i.e copper wires, switch, socket, led lights, cables, mcb, chowk, starter etc for temporary arrangement for various army personnel deployed at red fort during independence day celebration 2020 [ each ] 10 sqmm copper wire havells or equivalent 35 6 sqmm copper wre havells or equivalent 36 4 sqmm copper wire havells or equivalent 37 2.5 sqmm copper wire havells or equivalent 38 1.5 sqmm copper wire havells or equivalent 39 10 sqmm 2 core aluminium wire kalinga or equivalent 40 submersible wire 6 sqmm 3 core copper wire isi marked 41 sodium chowk 250 watt isi marked 42 sodium bulb 250 watt isi marked 43 ignitor isi marked 44 sodium light holder isi marked 45 tube 36 watt isi marked 46 electronic chowk 36 watt isi marked 47 tube side holder normal isi marked 48 tube starter isi marked 49 16 amp 3 pin top isi marked 50 6 amp 3 pin top isi marked 51 16 amp power combine with box isi marked 52 pandenant holder isi marked 53 100 watt bulb isi marked 54 water proof tape roll isi marked 55 pvc tape roll isi marked 56 cotton tape isi marked 57 tpn isolator isi marked 100 amp 58 1 pvc pipe isi marked 59 1 pvc batten isi marked 60 6mm telephone gitti 61 63 amp tpn isolater isi marked 62 dp mcb box isi marked 63 63 amp dp mcb isi marked 64 40 amp dp mcb isi marked 65 32 amp dp mcb isi marked 66 7.5 hp starte panel for fountain motor isi marked 67 32 amp mcb isi marked 68 16 amp mcb isi marked 69 bottle type thimble aluminium 70 25mm bottle type thimble aluminium 71 25mm ring type thimble aluminium 72 ceiling fan 48 crompton / usha or equivalent 73 exhaust fan 12 crompton or equivalent 74 pedestral fan crompton or equivalent 75 wall fan crompton or equivalent 76 36 watt tube fitting complete isi marked 77 100 watt led flood lights isi marked 78 led lights 110 watt for pole isi marked 79 6 amp switch isi marked 80 6 amp socket isi marked 81 16 amp switch isi marked 82 16 amp socket isi marked 83 3.15 mfd fan capacitor isi marked 84 wooden screw 1.5 85 pvc gutty 1.5 86 fan regulator isi marked ] 87 11x13 sheet 88 9x11 sheet 89 8x5 sheet 90 gi winding wire 91 6mm hammer bit 92 nut bolt warsel 93 voltage meter ( multi meter ) 94 electrical tools 95 brass screw 1.5 96 brass screw 1 97 cable tie 9 98 bed switch 99 cfl 18 watt 100 provision for purchasing, supplying and fixing of sanitary articles including all labour and material etc. compete. [ each ] gi pipe 6” dia 10 foot length 101 gi 4” dia nipple 4” length 102 gi 4” flench 103 gi 2” socket 104 gi 4” nipple 105 gi 2” nipple 106 gi 1 / 2” hex nipple 107 gi 1 / 2” socket 108 gi 1 / 2” elbow 109 2” clamp 110 ppr pipe 1” 10 foot length 111 ppr 1” elbow 112 ppr 1” socket 113 ppr 1” f tee 114 ppr 1” m tee 115 2” brass ball valve 116 safeda 117 thread 118 nut bolts3” ( 4 soot ) 119 hexa blade 120 m seal 121 double symphon 122 cistern complete set 123 towel rod 124 towel ring 125 soap container 126 short pillar cock 127 long body cock 128 cap 129 cpvc 1” ball valve 130 cpvc 1” pipe 131 cpvc 1” socket 132 cpvc 1” elbow 133 cpvc t 1” 134 cpvc union 1” 135 cpvc 1’ ball valve 136 cpvc 1” f t 137 cpvc 1” mt 138 cpvc 2” ball valve 139 cpvc 2” pipe 140 cpvc 2” socket 141 cpvc 2” socket 142 cpvc t 2” 143 cpvc union 2” 144 cpvc 2”x1” reducer 145 cpvc plug cap 2” 146 cpvc plug cap 1” 147 cpvc 3 / 4” t 148 cpvc 3 / 4” socket 149 cpvc 3 / 4” elbow 150 cpvc cap 3 / 4” 151 cpvc union 3 / 4” 152 cpvc tank nipple 3 / 4 ] 153 3 / 4” ball cock brass 154 tank nipple 1” 155 ft 3 / 4” 156 hand spray ss 157 angle valve 158 pvc connection pipe 2; 159 cp cap 160 2in1 toti 161 european seat cover 162 sintex tank 500 litre for army 163 plumber tools 164 1” ball cock brass 165 cpvc solvent 166 3 / 4” ball cock bras ] 167 gi nipple 6” length x 1”dia 168 gi nipple 9” length x 1” dia 169 cpvc elbow 1” 170 cpvc socket 1” 171 submersible electric motor 1 hp crompton or equivalent 172 rubber pipe 1” [ each ] 173 sintex tank 500 liter 174 unslacked lime ( free from dust ) 175 surkhi 176 coarse sand 177 gur 178 gum 179 belgiri...

Northern Railway - Delhi

24224655 supply of , dual coat round copper winding wire size 18 swg [1.2192mm]nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s....

Northern Railway - Delhi

24066628 supply of , dual coat round copper winding wire size 21swg [0.813mm]nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s....

Military Engineer Services - Delhi

23703138 repair / replacement and maintenance of connected items of summer appliances at zone b area under ge ( i ) rnd delhi sl.no. item description item code / make quantity units 1 1 m & l for servicing of the window ac 1.5 / 2 ton capacity of any make, including oiling / greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and as directed n note: ( i ) any u / s items need to be replaced / gas charging etc shall be measured & paid seperately under respective items. ( ii ) the cost of dismantling, taking out window ac 1.5 / 2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted. 75 each 2 2 all same as per ser item no. 1.00 above but for split type ac / inverter type ac 1.5 / 2.0 / 4.1 ton 240 each 3 3 all same as per ser item no. 1.00 abov but for vrf inverter split type 3 phase ac of capacity 8 tr. 1 each 4 4 s&f in repair fan motor of ac ( window / split type ) 1.5 tr capacity of approved make and required size to suit existing ac complete all as specified and as directed. nmake : aue / fragmeter 4 each 5 5 all same as per ser item no. 4.00 above but ac ( window / split type ) . 2.0 tr capacity 2 each 6 6 s&f for rewinding of fan motor of ac 1.5 / 2.00 tr capacity, ( window / split type ) of any make with super enameled copper wire of appropriate gauge and quantity complete all as specified and as directed. 5 each 7 7 s&f in repair air circular blower fan motor of ac ( split type ) , 1.5 tr / 2.0 / 3.00tr capacity including taking out unser viceable air circular blower fan motor complete all as specified and directed. 4 each 8 8 s&f in repair air filter suitable of ac ( window type ) 1.5 tr / 2.0 tr capacity including taking out unserviceable air filter from ac complete all as specified and as directed. 4 each 9 9 s&f in repair air filter suitable of ac ( split type ) 1.5 tr / 2.0 tr capacity air complete all as specified and as directed. make : usha / universal 10 each 10 10 s&f in repair capacitor running 36 mfd – 45 mfd suitable for new / star rated for ac ( window / split type ) 1.5 tr / 2.0 tr capacity complete all as specified and as directed. 30 each 11 11 s&f in repair capacitor starting 80 mfd – 120 mfd suitable for ac ( window / split type ) 1.5 tr / 2.0 tr capacity complete all as specified and as directed. nmake : usha / universal 30 each 12 12 s&f in repair fan motor blades ac ( window / split type ) 1.5 / 2.0 tr capacity complete all as specified and directed. 10 each 13 13 s&f in repair fan motor capacitor 4 mfd of suitable for ac ( window / split type ) 1.5 / 2.0tr capacity complete all as specified and directed. 20 each 14 14 s&f in repair fan capacitor 6 mfd for fan motor suitable for ( window / split type ) 1.5 / 2.0tr capacity complete all as specified and directed. 18 each 15 15 s&f in repair front plastic grill ( as per sample ) of ac ( window type ) 1.5 tr / 2.0 tr capacity complete all as specified and directed. 2 each 16 16 s&f in repair front plastic grill for inner unit ( as per sample ) of ac ( split type ) 1.5 tr / 2.0 tr capacity complete all as specified and directed. 2 each 17 17 s&f in repair runner for air blower motor of ac ( split type ) ac 1.5 / 2.00tr capacity ( as per sample or as per site requirement ) complete all as specified and as directed. 5 each 18 18 s&f in repair single pole contactor 25a capacity, mr 11w type as approved suitable for ac ( split type ) complete all as specified and as directed. 4 each 19 19 s&f in repair selector switch of ac ( window / split type ) 1.5 tr / 2.0 / 3.0 tr capacity complete all as specified and as directed. 10 each 20 20 s&f in repair selector switch knob of ac ( window / split type ) 1.5 tr / 2.0 / 3.00 tr capacity complete all as specified and as directed. 10 each 21 21 s&f in repair starting relay of ac ( window / split type ) 1.5 tr / 2.0 / 3.00tr capacity complete all as specified and as directed. 20 each 22 22 s&f in repair strainer with capillary tube of ac window / split type ) 1.5 tr / 2.0 / 3.0 tr capacity complete all as specified and as directed. 25 each 23 23 s&f in repair thermostat switch of ac ( window / split type ) 1.5 tr / 2.0 / 3.0 tr capacity complete all as specified and as directed. 10 each 24 24 s&f in repair cooling coil suitable for window type room ac 1.5 / 2 ton . 2 each 25 25 s&f in repair condensing coil suitable for window type ac 1.5 / 2 ton 2 each 26 26 s&f in repair condensing coil suitable for split upto 2 ton capacity. 2 each 27 27 s & f in repair cooling coil suitable for split type ac upto 2 ton capacity 2 each 28 28 s&f in repair indoor unit suitable for 1.5 tr split type ac complete all as specified and directed. 5 each 29 29 s&f in repair outdoor unit suitable for 1.5 tr split type ac complete all as specified and directed. 5 each 30 30 s&f in repair indoor unit suitable for up to 2 tr split type ac complete all as specified and directed. 2 each 31 31 s&f in repair outdoor unit suitable for up to 2 tr split type ac without compressor complete all as specified and directed. 2 each 32 32 s&f in repair of hermitacally sealed compressor for split / window type ac capacity 1.5 ton. 6 each 33 33 s&f in repair of hermitacally sealed compressor for split / window type ac capacity 2.0 ton. 6 each 34 34 taking down / up defective ac 1.5 tr capacity ( window / split type ) , transportation from mes store yard / site to workshop and back including re fixing / re installing after taking out defective / burnt com pressor sealed unit and providing new compressor rotary / reciprocating as per site requirment of same capacity from authorised dealer including flushing of condenser and charging with required quantity of appropriate refrigerant gas r22 / r410 including re connection of electric connections, functioning ac complete in all respect and testing, complete all as specified and as directed. make : kirloskar / emersion 6 each job 35 35 all same as per item no. 34.00 above but ac 2.0 tr capacity ( window / split type ) . 4 each job 36 36 s&f in repair pcb with remote for window type ac up to 2 ton capacity complete all as specified and directed . 4 each 37 37 s&f in repair pcb with remote for split type ac 2 / 3 ( 1.5x2 ) ton capacity complete all as specified and directed . 6 each 38 38 s&f in repair pcb & motherboard with remote complete set for inverter split type ac up to 2 ton capacity complete all as specified and directed . 12 each 39 39 s&f in repair remote of ac ( window / split type ) 1.5 / 2.0 tr capacity ( as per sample or as per site requirement ) all as specified and as directed. 4 each 40 40 s&f in repair wiring kit suitable for 1.5 to 2.0 ton capacity ac complete all as specified and directed. 30 each 41 41 s&f in repair gas charging pin valve complete all as specified and directed. 40 each 42 42 taking out window type ac complete unit from any height / any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed. 6 each job 43 43 taking out split type ac complete indoor and outdoor unit from any height / any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed. 4 each job 44 44 supply and charging the gas refrigerant r22 ( including refrigerant ) of window type ac upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed. 100 kg 45 45 all same as per ser item no. 44.00 above but r 410 / 32 for split type ac up to 2 tr capacity complete. 250 kg 46 46 all same as per ser item no 44.00 above but cassatte type ac 4 tr capacity complete. 24 kg 47 47 all same as per ser item no 44.00 above but vrf unit 8 tr capacity complete. 12 kg 48 48 s&f in repair of casing of window type ac including complany fitted condensing & cooling coil complete including pcb except compressor complete 4 each 49 49 s&f in repair of split valve ¼” for split ac up to 2.00 ton capacity complete all as specified and directed. 4 each 50 50 all same as per ser item no. 49.00 above but 1 / 2. 4 each 51 51 s&f in repair compressor shut off valve 3 / 8 for split ac up to 2.00 ton capacity complete all as specified and directed. 4 each 52 52 s&f in repair compressor shut off valve 5 / 8 for split ac up to 2.00 ton capacity complete all as specified and directed. 4 each 53 53 s & f in repair of electrolyte grade copper tubing of size 1 / 4 suitable for any type of split type ac including synthetic rubber foam complete all as specified and directed. note : the quoted rate is inclusive of necessary t&p, rope, ladder etc with safety equipment for execution the work upto six stories building. 100 rm 54 54 all same as per ser item no. 53.00 above but size 1 / 2 120 rm 55 55 all same as per ser item no. 53.00 above but size 3 / 8 40 rm 56 56 all same as per ser item no. 53.00 above but size 5 / 8 40 rm 57 57 s&f in repair pvc conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of acs to this conduit for proper drainout of condensate water from acs of bldgs upto 5 ( five ) storey complete all as specified and directed. 150 rm 58 58 s&f in repair pvc conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of acs to this conduit for proper drainout of condensate water from acs of bldgs upto 5 ( five ) storey complete all as specified and directed. 150 rm 59 59 s&f in repair of synthetic rubber foam for insulation for refrigerant copper piping of existing size 1 / 4 to 5 / 8 internal dia split type ac complete all as specified and directed suitable for the under mentioned sizes. note : the quoted rate is inclusive of necessary t&p, rope, ladder etc with safety equipment for execution the work upto six stories building. 300 rm 60 60 s&f in repair hermatically sealed compressor for 40 / 80 ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted. 2 each 61 61 s&f in repair hermatically sealed compressor for 60 / 120 ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted. 2 each 62 62 s&f in repair metal plug top 3 pole and earth, 20 amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed. make: l&t / siemens / schneider. 25 each 63 63 s&f in repair metal enclosures with clad socket & plug top 3 pole and earth, including of mcb sp 25 amps 240 volts complete all as specified and directed. make: l&t / siemens / schneider. 25 each 64 64 s&f in repair of pvc insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 sqmm complete all as specified and directed. make: rr kabel / finolex / havells. 90 rm 65 65 s&f in repair of pvc insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 sqmm complete all all as specified and directed. make : rr kabel 60 rm 66 66 s&f in repair for submain wiring including pvc casing capping 2 run 4.00 sqmm cable pvc insulated copper conductor multi stranded as per frls cable drawn through conduit pvc 20mm dia mediam duty with all accessories including 4.0 sqmm single strand copper conductor cable pvc insulated unsheathed for earth continuity connected to common earth dolly and all as specified . 100 rm 67 67 s&f in repair ac stand suitable for out door ac unit up to cap of 2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication including two coat of synthetic enamel paint over a coat of primer and nuts & bolts etc upto six stories building complete all as specified and as directed. 8 each 68 68 s&f in repair reverse valve system made of copper for heating option suitable for 1.5 / 2.0 ton split / window type ac including appropriate gas charging complete all as specified and as directed. 4 each 69 69 taking down defective water cooler 40 / 80 litre capacity, transportation from mes store yard / site to workshop and back including re fixing / reinstall ing, testing, connecting the same after replace ment of defective / burnt compressor selected unit with new compressor from authorised dealer including flushing of condenser and charging with required quantity of appropriate refrigerant gas, complete all as specified and as directed. 4 each 70 70 s&f for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed. 15 each job 71 71 supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed. 6 each job 72 72 s&f in repair starting relay / over load relay suitalbe for water cooler of any make & size complete all as specified and directed. make : renutrol or equivalent 2 each 73 73 s&f in repair starting relay / over load relay suitalbe for water cooler of any make & size complete all as specified and directed. make : renutrol or equivalent 4 each 74 74 s&f in repair defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. 4 each 75 75 s&f for preparation of old painted surfaces of water cooler by removing old deteriorated paid, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting. 4 each job 76 76 s&f in repair fan motor isi marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed. 3 each job 77 77 s&f in repair of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed. 3 each 78 78 s&f in repair 15 mm dia pvc connection of length upto 600mm with ptmt nuts on both ends complete all as specified and directed. 10 each 79 79 s&f in repair condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed. 2 each 80 80 s&f in repair steel / aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed. 2 each 81 81 s&f for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair / replacement of defective / unserviceable parts, reasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. note : unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule. 20 each job 82 82 s&f for painting of desert cooler capacity upto 4000 cuf with two coats of approved synthetic enamel paint inside & outside including fan / fan blade / brackets after scrapping the rust, peal of paint and preparation of surface complete all as specified and directed. nnote : the rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting. 20 each job 83 83 s&f in repair of desert cooler sub mersible water pump complete with electric motor single phase 230 volts 50hz including lead, connecting & testing. make: khaitan, bajaj, havells, crompton 15 each job 84 84 s&f in repair desert cooler fan motor, copper wound suitable for upto 450mm sweep sp 230 volts 50hz including legs, rubber bush nuts / bolts for fixing of fan motor complete with connection & testing. make: khaitan, bajaj, havells, crompton 15 each job 85 85 s&f in repair of commercial ply wood bwp 4mm thick isi marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed ( frame should be in single piece ) 4 sqm 86 86 s&f in repair plug top 3 pin 5 amps make : anchor, bajaj, havells 50 each 87 87 s&f in repair plug top 3 pin 15 amps make : anchor, bajaj, havells 30 each 88 88 s&f in repair motor capacitor 2.5 / 3.15 / 4 mfd. 150 each 89 89 s&f in repair front grill made of ms complete with air guide vanes suitable for desert cooler of capacity 4000 cuf. 10 each 90 90 s&f in repair of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed 10 each 91 91 s&f in repair of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed. 30 each 92 92 s&f in repair of float valve assembly with ptmt ferrule 15 mm dia and pvc ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 cuf complete all as directed 15 each 93 93 s&f new wood wool pad, ( khus khas ) set of three covered by gi wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed 20 each set 94 94 s&f in repair of switch piano, flush type single pole, one way, 5 amp 230 v ac isi marked complete all as specifed and directed make kinjal / cona / anchor / ssk 50 each 95 95 s&f in repair of aluminium multi wing fan blade, best quality as per existing type and size suitable for of desert cooler complete all as specifed and directed 5 each 96 96 taking down ceiling fan / exhaust / pedestal / table / air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding / overhauling / engrawing of mes no of fans and fixing the same in eixsting position or as directed by engineer in charge with eletric connection and testing complete all as specified and directed nnote : rewinding shall be measured and paid seperately. 20 each 97 97 s&f for overhauling of ceiling fan / pedestal / exhaust / table / aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed. 50 each 98 98 s&f for removing of burnt out winding wire from ceiling fan of any make of size 1200 / 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size / gauge including insulating material and varnishing complete all as directed. 50 each 99 99 all same as per ser item no 98.00 above but for exhaust fans of size 225 mm sweep to 380 mm sweep 15 each 100 100 all same as per ser item no 98.00 above but for exhaust fan of size 450 mm sweep 10 each 101 101 all same as per ser item no 98.00 above but for pedestal fan / air circulator fan of size 400 mm to 600 mm sweep. 2 each 102 102 all same as per ser item no 98.00 above but for table fan / wall mounted of 400 mm sweep 5 each 103 103 s&f for replacement of defective ball bearing for ceilng / table / pedestal / air circulators fan of any size ( bearing make / size skf 6201 / 6202 / or equivalent make ) 50 each 104 104 all same as per ser item no 103.00 above but for xhaust fan any of size / make skf 6203 / 6204 or equivelent make. 10 each 105 105 s&f in repaor of rubber seal of suitable size for ceiling fan complete all as specified and directed 50 each 106 106 s&f in repair of gun metal bush suitable for any type / model / size of fans complete all as directed. make: as per sample 20 each 107 107 s&f in repair of ceiling fan regulator five step 60 / 120 watt electronic type ac 230 / 240 volts suitable for 1200 / 1400 mm sweep complete with all fixing accessories including necessary electric connection all as specified and directed. 20 each 108 108 s&f for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by spraying after filling cavities with filler and preparation of surface complete including marking mes no etc all as specified & directed. 20 each 109 109 all same as per ser item no 108.00 above but exhaust fan of size 250 / 300 mm sweep complete. 15 each 110 110 all same as per ser item no 108.00 above but for exhaust fan of size 450 mm sweep 10 each 111 111 s&f in repair of pvc canopy suitable for 1200 / 1400 mm sweep ceiling fan complete all as directed 20 each 112 112 s&f in repair voltage stabilizer 4 kva suitable for window / split type ac of capacity upto 1.5 tr working on ac 240 v, 50hz single phase all as specified and as directed. make: v guard or equivalent. 5 each 113 113 s&f in repair voltage stabilizer 5 kva suitable for window / split type ac of capacity upto 2 tr working on ac 240 v, 50hz single phase all as specified and as directed. make: v guard or equivalent 3 each 114 114 s&f in repair wall mounted fan 450mm sweep working on ac 240 v, 50hz, single phase all as specified and as directed. make: bajaj, havells, anchor, crompton 5 each 115 115 s& f in repair pedestal fan 450mm sweep working on ac 240 v, 50hz, single phase all as specified and as directed. make: bajaj, havells, anchor, crompton 5 each 116 116 s&f in repair exhaust fan pvc body 250mm sweep working on ac 240 v, 50hz, single phase all as specified and as directed. nmake: bajaj, havells, anchor, crompton 10 each 117 117 taking down of geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc complete all as directed and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position. 2 each job 118 118 all as per ser item no. 117 here in before but capacity 50 ltrs complete all as specified and directed. 2 each 119 119 s&f in repair of heating element triangle / round type as existing of capacity 1.5kw of hot appliances complete all as specified and directed. . 2 each 120 120 all as per ser item no. 119 here in before but capacity 2kw complete all as specified and directed. 2 each 121 121 s&f in repair of thermostate as existing of capacity 25 / 50 ltrs of hot appliances complete all as specified and directed. . 2 each 122 122 s&f in repair oil room heater 2900 watt suitable for 11 fin, weight 18 kg with fan complete all as specified and as directed.of havells model no ofr 11 fin or equivalent / bajaj / morphy. 3 each 123 123 s&f in repair of shut off valve as existing of capacity 25 / 50 ltrs of hot appliances complete all as specified and directed. . 2 each 124 124 s&f in repair of thermo insulation glass wool as existing of capacity 25 / 50 ltrs of hot appliances complete all as specified and directed. . 2 each job 125 125 s&f in repair of water connection cp for inlet & outlet ( hot & cold ) as existing of capacity 25 / 50 ltrs of hot appliances complete all as specified and directed. . 2 set of two 126 125.01 note for ser item no. 1 to 125 : n1. the contractor shall provide and deploy sufficient technician with helpers ( as directedd by ge / engineer in charge ) and contractors site supevisor / site engineer shall report at 0900 hrs daily excluding sunday & holiday to collect the complaints job card & complete the same complaint detailed by je e / m engineer in charge ( with in 48 hrs ) n2. the complaints shall be attended with in 48 hrs. if the complaints is / are not attended / not complited on same day ( except repair / replacement of major items like replacement of compressor, cooling coil, condensing coil and fan motor etc. ) recovery will be done as follows n ( a ) after 48 hrs, rs 1000.00 per complaint per day. nthe decesion of ge on recovery against penalty shall be final and binding and no representation whatsoever shall be entertained. n3. the technicians for repair of summer appliances can be called during non working days / hrs ( i.e. sunday, holidays & after working hrs ) for any vital complaint at drdo area. n4. the contractor has to produce job card duly signed by user & je e / m to engineer in charge....

Public Works Department - Delhi

22649807 open auction in respect of dismantled material of electro mechanical accessories as per survey report no . 23 to 36/ee ( e ) /pwd hmed sw/18 19 under sub division hsw 4 , pwd hmed sw , janak puri super specialty hospital , janak puri new delhi , 250a mccb 4 nospvc wire al . 16 kg . assorted g . i . pipe 1 . 5 6 dia 80 . 5 mtr . mono submersible/submersible pump 3 10hp 5 nosmono block pump 3 5 hp 2 nossubmersible pump 3 5 hp 1 nos15 hp motor pump 2 nos150 ah battery 2 noscpu 2 nosmechanical seal 2 nosgland plate 2 nosepabx 1 nospush button phone 4 nos7 . 5 tr compressor 1 kg . locks 100 nosr . o . membrane 3 nosdouble handed c . i . valve 80mm 1 nosco2 cylinder 4 . 5 kg 8 nos12v , 7ah battery 10 nosnrv 50/65/80/100/150mm 13 nosc . i . gate valve 50mm 2 nosdol starter 3 nos40w tube light fittings 65 nospvc copper winding wire 65 . 5 kg . , 3 x 4 sqmm cable 20 mtr . 63mm dia hydrant valve 5 nosfire box 4 nospressure gauge 21 nosair release valve 0 . 5 to 4 10 nos65/80/100/150mm dia sluice valve 19 nos . shut off nozzle 21 noscts 6 nosmulti port valve ( pvc ) 2 noscondensing coil 2 nosassorted butterfly valve 50/65/80/100/150mm 13 nosball valve 1 . 5/2 2 nosdomestic r . o . pump 2 noss800a 1600a d/o pole assembly 2 nosrear horizontal terminal 800 to 1600 4 noscluster contactor for s800 s1600a 11 nosmoving arcing contact 800 1600a 22 nosarcing moving contact 2000a 4 nosarcing tinned contact 2000a 2 nosfront fasia 2 nosarc chute 1 nos , all type relay 6 nos25 kvar capacitor 48 nospvc rotary handle 12 nosvoltmeter 2 nosammeter 1 nosunder voltage 1 noschangover switch 4 noselement oil filter 3 setdehydrator 3 nosfilter dayer 6 nosck 75 power contactor 1 nos3tf 33/32 contractor 2 nosassorted bearing 16 nospower pack 2 nosair blower 1 nosdosing pump upto 6 lph 1 nosdiffuser disc 20 kg . c . i . valve 3 5 nospost top 19 nospressure reducing valve 1 nosassorted switch 5/6a to 15/16a 1072 nos . assorted socket 5/6a to 15/16a 1425 nos . , fan regulator 2 m 342 nos . ignitor 32 nos . 11/14/28/36/40w choke 477 nos . sp mcb 5a to 32a 988 nos . dp mcb 5a to 63a 424 nos . tpn mcb 40a 136 nos . 4x14w fitting 195 nos . detector 323 nos . annunciator/ alarm panel 1 no . fcbc 12 . 5 a 1 no . acb 2000 amp 1 no . mcp 7 nos . rusted ms pipe 100/150mm dia 6 . 5 mtr . phenolic laminated sheet 8 x 5 81 nos . air filter 6 nos . capacitor 151 noscondensor fan motor 19 nosceiling fan 40 nosexhaust fan 1 nosassorted fitting 1x36w , 2x11w 46 nosscrap iron 30 kgi/o board 1 no . , switch oil level 1 no . wiring harness cable 2 nos . load meter 2 nos . fire hydrant box 3 nos . rusted panel with accessories 2 sqmtrusted hose reel drum 2 nos . desert cooler 2 nos . 3 phase energy meter 1 no . 600va ups 2 nos . ...

Public Works Department - Delhi

22646621 open auction in respect of dismantled material of electro mechanical accessories as per survey report no . 23 to 36/ee ( e ) /pwd hmed sw/18 19 under sub division hsw 4 , pwd hmed sw , janak puri super specialty hospital , janak puri new delhi , 250a mccb 4 nospvc wire al . 16 kg . assorted g . i . pipe 1 . 5 6 dia 80 . 5 mtr . mono submersible/submersible pump 3 10hp 5 nosmono block pump 3 5 hp 2 nossubmersible pump 3 5 hp 1 nos15 hp motor pump 2 nos150 ah battery 2 noscpu 2 nosmechanical seal 2 nosgland plate 2 nosepabx 1 nospush button phone 4 nos7 . 5 tr compressor 1 kg . locks 100 nosr . o . membrane 3 nosdouble handed c . i . valve 80mm 1 nosco2 cylinder 4 . 5 kg 8 nos12v , 7ah battery 10 nosnrv 50/65/80/100/150mm 13 nosc . i . gate valve 50mm 2 nosdol starter 3 nos40w tube light fittings 65 nospvc copper winding wire 65 . 5 kg . , 3 x 4 sqmm cable 20 mtr . 63mm dia hydrant valve 5 nosfire box 4 nospressure gauge 21 nosair release valve 0 . 5 to 4 10 nos65/80/100/150mm dia sluice valve 19 nos . shut off nozzle 21 noscts 6 nosmulti port valve ( pvc ) 2 noscondensing coil 2 nosassorted butterfly valve 50/65/80/100/150mm 13 nosball valve 1 . 5/2 2 nosdomestic r . o . pump 2 noss800a 1600a d/o pole assembly 2 nosrear horizontal terminal 800 to 1600 4 noscluster contactor for s800 s1600a 11 nosmoving arcing contact 800 1600a 22 nosarcing moving contact 2000a 4 nosarcing tinned contact 2000a 2 nosfront fasia 2 nosarc chute 1 nos , all type relay 6 nos25 kvar capacitor 48 nospvc rotary handle 12 nosvoltmeter 2 nosammeter 1 nosunder voltage 1 noschangover switch 4 noselement oil filter 3 setdehydrator 3 nosfilter dayer 6 nosck 75 power contactor 1 nos3tf 33/32 contractor 2 nosassorted bearing 16 nospower pack 2 nosair blower 1 nosdosing pump upto 6 lph 1 nosdiffuser disc 20 kg . c . i . valve 3 5 nospost top 19 nospressure reducing valve 1 nosassorted switch 5/6a to 15/16a 1072 nos . assorted socket 5/6a to 15/16a 1425 nos . , fan regulator 2 m 342 nos . ignitor 32 nos . 11/14/28/36/40w choke 477 nos . sp mcb 5a to 32a 988 nos . dp mcb 5a to 63a 424 nos . tpn mcb 40a 136 nos . 4x14w fitting 195 nos . detector 323 nos . annunciator/ alarm panel 1 no . fcbc 12 . 5 a 1 no . acb 2000 amp 1 no . mcp 7 nos . rusted ms pipe 100/150mm dia 6 . 5 mtr . phenolic laminated sheet 8 x 5 81 nos . air filter 6 nos . capacitor 151 noscondensor fan motor 19 nosceiling fan 40 nosexhaust fan 1 nosassorted fitting 1x36w , 2x11w 46 nosscrap iron 30 kgi/o board 1 no . , switch oil level 1 no . wiring harness cable 2 nos . load meter 2 nos . fire hydrant box 3 nos . rusted panel with accessories 2 sqmtrusted hose reel drum 2 nos . desert cooler 2 nos . 3 phase energy meter 1 no . 600va ups 2 nos . ...

Public Works Department - Delhi

22163048 notice inviting online bid for auction of unserviceable material 1 1200 / 1400 mm ceiling fan 2 15 / 16 amp & 5 / 6 amp socket 3 40 watt chowk 4 5 / 6 amp & 15 / 16 amp switch 5 fan condensor 6 ceiling rose 7 8 / 10 / 12 way db 8 5 / 25 / 32 / 40 amp dp / sp mcb 9 ( 2x2 ) 36 / 40 watt fitting 10 1 x 36 / 40 watt type fitting 11 2 x 11 box type fitting 12 9 / 11 watt bulkhead fitting 13 pvc cooper wire 14 100 / 125 / 200 / 250 amp mccb 15 4 / 5 hp submersible pump set 16 pump starter upto 5 hp 17 40 mm gi pipe 18 stainless steel shaft of pump 19 gun metal bush of pump 20 pvc impeller of pump 21 casing of pump 22 winding wire of pump 23 70 / 150 watt flood light fitting 24 allumium pvc wire 25 cubical panel approx 1.5 sq.mtr 26 battery charger of 25 kva dg set 27 frc fuse 28 3 x 4 sq.mm submersible cable 29 uvr relay 30 timer for 25 kva dg set 31 power contactor 32 change over switch of 25 kva dg set 33 gate / check valve of ( 40 mm ) 34 300 mm sweep type exhuast fan 35 gong bell of 6 / 9 inch 36 ( 7 x 4 ) ( 8x10 ) metal box 37 a / c compressor of 1.5 / 2 tr window type 38 blower moter of a / c 39 capacitor / condenssor of a / c 40 invertor / ups of 650 va 41 12 v battery 42 1.5 tr window ac 43 150 ltr capacity water cooler 44 running capaitor upto 2 tr ac 45 upto 5 hp mono submersible pump set 46 250 watt chowk 47 250 watt bulb 48 ignitor 49 4 / 6 / 8 way tp dbs 50 250 mm gate valve ( ci ) 51 100 mm gate valve ( ci ) 52 100 mm check valve ( ci ) 53 20 / 25 mm ms conduit 54 gi street light poles 8 12 mtrs 55 street light bracket 0.5 1 mtrs 56 street light hpsv fittings up to 400 watt 57 flyover u / d fitting up to 40 watt 58 electric cable up to 4x25 sq. mm 59 submersible pump 3 hp 60 2 x 40 watt fitting 61 up to 400 mm exhaust fan 62 1.1 kw ama portar pump 63 surface / recess down lighters 10 18 w 64 led batten fitting 65 led street light fittings 70 watt...

Northern Railway - Delhi

21566260 supply of dual coat round copper winding wire size 19swg [1.0160mm]nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s., dual coat round copper winding wire size 19swg [1.0160mm]nominal diameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 or allortherm 602 l 35 s....

Defence Research And Development Organisation - Delhi

21489023 supply of consumables for air conditioning items for drdo bhawan new delhi , wires and cables : , supply of 6 sqmm single core pvc insulated copper conductor cable . , supply of 3c x 2 . 5 sqmm pvc insulated , unsheathed multistranded copper conduct wire . , supply of 4c x 10 sqmm 1 . 1 kv , xlpe insulated armound copper conductor cable . , supply of 3 core x 1 . 5 sqmm copper wire , supply of 3 core x 1 sqmm copper wire , supply of 4 core x 1 sqmm copper wire , exhaust fans : , supply of 250 mm sweep ventilating fan . , mcbs/mccbs/mpcbs : , supply of following rating mccb/mpcb . , 100 a tp mccb , 25 ka , 20 25 a mpcb , 15 ka , 32a , 10ka , dpmcb , gi pipes and fittings : , supply of 20 mm dia class b gi pipe . , supply of 25 mm dia class b gi pipe . , supply of 40 mm dia class b gi pipe . , thimbles/nut/bolts/washer : , supply of thimbles suitable for following cable . , 6 sqmm ring type copper , 16 sqmm ring type copper , 10 sqmm copper thimble , 35 sqmm copper thimble , supply of nut , bolts . , nult bolt 6 mm x 40 mm , nult bolt 10 mm x 40 mm , contactor/relays/indication lamps : , supply of following contactor suitable to work on 240/415 v hz , contactor mnx 18 a tp , contactor mnx 25 a tp , supply of relay mn2 9 15 amp suitable for 230v/415v , 50 hz . , supply of led indication lamp red/green / yellow/ blue . , supply of add on block 2 no + 2 nc on existing contactors . , supply of three phase voltmeter digital type 0 500 v class 1 . , ball valves and flanges : , supply of following dia ball valve . , 1/4 , 5/8 , 3/4 , 1/2 , supply of ms flanges/nozzles . , ms blind flange 10 , ms blind flange 8 , nozzle pp , inline fan with motor : , supply of inline bare fan , impeller & motor 0 . 75 kw all complete . , supply of alkaline battery 9 volt . , hvac items: , supply of gases , refrigerant and tools related to hvac . , r 22 , r 407 , r 410 , r 134 a , n2o , o2 , supply of condensor coil of 2 tr capacity . , bearing : , supply of bearing of following size . , i ) 6309 , ii ) 1209 gk , iii ) 2309 k , iv ) h 2312 , v ) uk 211 , vi ) ukp 212 , vii ) 32309 , viii ) pillow bearing p212 j , supply of valves of following size . , pin valve 1/4 , bib cock brass with syphon , butterfly valve 200 mm , butterfly valve 250 mm , nrv 200 mm , cooling tower spares: , supply of following cooling tower spares . , fill retainer cap , fill sheet 6x4 , frp kit for leakage , gear support box , 15hp capacity motor , pillar support , ss hanger , coil shine , gear oil 90 grade , cooling tower blade with seat , supply of following spares of pump/motor 15hp all complete as specified and directed . , mechanical shaft seal , mechanical seal bush , air seal 102 x 7 . 5 gi , air seal 24 x 12 gi , rubber coupling 0 . 14 , rubber coupling 0 . 15 , float valve 1 , supply of temperature indicator controller . , paint : , supply of synthetic enamel paint of approved colours . , supply of frp putty , repair and service : , repair/rewinding the electric motor/monoblock pump set with super enamelled copper winding copper winding wire of existing gauge and turn including helping material such as varnish , cotton tape , pvc tape , glasswire , sleeve , thimble all complete as specified and directed but of following capacity : , i ) 10 hp , ii ) 15 hp , iii ) 30 hp , supply of cooling tower fills including cleaning , fixing , mechanical work and service charges all complete as specified and directed . , supply of unservicable pcbs of split / window air conditioners . , window ac 1 . 5 ton , split ac 1 . 5/2 ton , supply of rotary compressor of existing following capacity for window / split airconditioners all complete as specified . , rotatry compressor 1 . 5/2 tr , supply of motor of existing following capacity all as specified and directed . , condenser motor 93 w , water cooler motor 3/4 hp . , condenser fan motor 25 w , supply of float valve 1/2 for water cooler , supply of pressure gauge , supply of temperature gauge , supply of water cooler bib cock long , supply of water cooler bib cock short , supply of belt b 97 , supply of belt b 96 , supply of belt b 110 , supply of o ring replacement , supply of 15 amp 3 pin top , supply of batten 1 ( length 2 metre ) ) , supply of pvc box 3x3 , supply of thermostate , supply of damper actuator , supply of electrical transformer 24 volt , supply of motorised damper with thermostate , supply of flexible duct 8 , supply of normal damper , supply of firoja paint , ms . pipe 3 class c , ms . pipe 4 class c...

Northern Railway - Delhi

21027555 tender for set of items ( one set consists of following items for track feed battery charger 10 ampere)item list : (1) set of items ( one set consists of following items for track feed battery charger 10 ampere) 1.)transformer for track feed battery charger 10 amp. to irs s.89/2013 ver. 1.0 along withholding bracket and fixing accessories.transformer as per rdso specification irs s 89/2013 ver.1.0 transformer used shall be impragnated and shall be of natural aircooled type and shall be confirm is:697 class f or higher grade insulating material asper is:1271 and polyster enameled copper winding wire confirming to is: 13730(pt 3) shallbe used for winding transformers. input voltage 0 90 100 110 v ac output voltage 0 3.894 5.41 7.01 8.27 at the load of 5.0 amp dc load sensure voltage 15.21 vac.voltageregulation less than 5% no load current less than 10% of the full load current.fourth tapping 10 amp. dc load 8.12 volt efficiency not less than 95%. 2.) filter chokefor tfbc 10 amp. 360+/ 2 (plus or minus) micro henry 100 hz as per rdso specification irs s 89/2013, version 1.0 with m.s. threaded terminations. (a) the size should be 60mm x 80mm x70mm inclusive of insulation. (b) ripple contents less 5% while using with pie filterhaving 2 nos. of condensor 47000 micro ferad with input voltage setting of 2v, 4v, 6vand 8v. (c) suitable higs to be provided in the choke for fixing. (d) winding should bevacuum impregenate and shall be of natural air cooled type and shall be confirmedto is 6297 class f or higher grade insulating material as per is 1271 and polysterenameled copper winding wire confirming to is 13730 (part 3). (e) the sample to beapproved before commencing bulk supply...

Archaeological Survey Of India - Delhi

21011081 supply of materials for the work special repair to independence day celebration 2019 at red fort 34. 32 amp mcb isi marked 35. 16 amp mcb isi marked 36. bottle type thimble aluminum 37. ring type thimble aluminum 38. 25mm bottle type thimble aluminum 39. 25mm ring type thimble aluminum 40. ceiling fan 48” crompton/usha 41. exhaust fan 12” crompton or eq. 42. pedestral fan 12” crompton or eq. 43. wall fan crompton or eq. 44. 36 watt tube fitting complete isi marked 45. 100 watt led flood lights isi marked 46. led lights 110 watt for pole isi marked 47. 6 amp switch isi marked 48. 6 amp socket isi marked 49. 16 amp switch isi marked 50. 16 amp socket isi marked 51. 3.15 mfd fan capacitor isi marked 52. wooden screw 1.5” 53. pvc gutty 1.5” 54. fan regulator isi marked 55. 11x13 sheet modular 56. 9x11 sheet modular 57. 8x5 sheet modular 58. gi winding wire 59. 6mm hammer bit boss or eq. 60. nut bolt warsel 61. voltage meter (multi meter) 63. brass screw 1.5” 64. brass screw 1” 65. cable tie 9” 66. bed switch 67. cfl 18 watt c) provision for purchasing, supplying fixing of sanitary articles including labour and material etc. compete. 1. gi pipe 6” dia 10 foot length 2. gi 4” dia nipple 4” length 3. gi 4” flench of isi 4. gi 2” socket of isi 5. gi 4” nipple of isi 6. gi 2” nipple of isi 7. gi ½”hex nipple of isi 8. gi ½” socket of isi 9. gi ½” elbow of isi 10. 2” clamp of isi 11. ppr pipe 1” 10 foot length of isi 12. ppr 1” elbow prakash or eq. 13. ppr 1”socket prakash or eq. 14. ppr 1” f tee prakash or eq. 15. ppr 1” m tee prakash or eq. 16. 2” brass ball valve of isi 17. safeda 18. thread 19. nut bolts3” (4 soot) 20. hexa blade 21. m seal 22. double symphon 23. cistern complete set pvc parryware of eq. 24. towel rod isi 25. towel ring isi 26. soap container isi 27. short pillar cock hindware/parryware or eq. => open tender...

Indian Army - Delhi

20979790 procurement of stores: winding wire swg no. 24 super enameld copper, winding wire swg no. 21 copper, armature for hand grinder, carbon bush for hand grinder, oil spin 5=> limited....

Northern Railway - Delhi

20362970 supply of dual coat round copper winding wire size 21swgitem list : ( 1 ) dual coat round copper winding wire size 21swg [ 0.813mm ] nominal diameter confirming to is: 13730 13 / iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [ 1 ] base coat [ pe ] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860 / 35 lyc [ 2 ] top coat [ pai ] ai 1013 bv / 35 or allortherm 602 l 35 s....

Northern Railway - Delhi

20362618 supply of dual coat round copper winding wire size 19swgitem list : ( 1 ) dual coat round copper winding wire size 19swg [ 1.0160mm ] nominal diameter confirming to is: 13730 13 / iec 60317 grade 2 or 2b. the enamel for making class 200 wire shall be of dr. beck india ltd. as follows [ 1 ] base coat [ pe ] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860 / 35 lyc [ 2 ] top coat [ pai ] ai 1013 bv / 35 or allortherm 602 l 35 s....

Northern Railway - Delhi

20107719 tender for dual coat super enamelled copper winding wire of size 18 swgitem list : (1) dual coat super enamelled copper winding wire of size 18 swg confis:13703 pt. xiii dy.cmmamv/lko uttar pradesh 1510.00 kgdy.chief material haryana 700.00 kg...

Northern Railway - Delhi

20006671 tender for dual coat round copper winding wire size 23swg item list : (1) dual coat round copper winding wire size 23swg [0.6096mm] nominaldiameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for makingclass 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 orallortherm 602 l 35 s.dy.chief material haryana 476.00 kgmanager/judw...

Northern Railway - Delhi

20006545 tender for dual coat round copper winding wire size 16 swg item list : (1) dual coat round copper winding wire size 16 swg [1.6256mm]nominaldiameter confirming to is: 13730 13/iec 60317 grade 2 or 2b. the enamel for makingclass 200 wire shall be of dr. beck india ltd. as follows [1] base coat [pe] terbec tr 543 38 or terbec mt 533 36 pa or isomid 860/35 lyc [2] top coat [pai] ai 1013 bv/35 orallortherm 602 l 35 s.dy.cmmamv/lko uttar pradesh 1000.00 kg...